ISO 15586:2003
Water quality — Determination of trace elements using atomic absorption spectrometry with graphite furnace
Water quality — Determination of trace elements using atomic absorption spectrometry with graphite furnace
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 23
- Дата публикации:
- 8 октября 2003 г.
- Издание:
- ISO IS 15586 edition 1 version 1
- ICS:
- 13.060.50
ISO 15586:2003 includes principles and procedures for the determination of trace levels of: Ag, Al, As, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, Pb, Sb, Se, Tl, V, and Zn in surface water, ground water, drinking water, wastewater and sediments, using atomic absorption spectrometry with electrothermal atomization in a graphite furnace. The method is applicable to the determination of low concentrations of elements. The detection limit of the method for each element depends on the sample matrix as well as of the instrument, the type of atomizer and the use of chemical modifiers. For water samples with a simple matrix (i.e. low concentration of dissolved solids and particles), the method detection limits will be close to instrument detection limits. The minimum acceptable detection limit values for a 20-microlitre sample volume are specified.
Abstract
Overview
ISO 15586:2003 - "Water quality - Determination of trace elements using atomic absorption spectrometry with graphite furnace" - specifies principles and procedures for measuring low (trace) concentrations of 17 elements (Ag, Al, As, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, Pb, Sb, Se, Tl, V and Zn) in surface water, ground water, drinking water, wastewater and sediments. The method uses atomic absorption spectrometry (AAS) with electrothermal atomization in a graphite furnace (graphite furnace AAS) and defines sample preparation, chemical modification, calibration, interferences and reporting. Minimum acceptable detection limits for a 20 µl sample volume are given (e.g., Cd ≈ 0.1 µg/L, Pb ≈ 1 µg/L, Zn ≈ 0.5 µg/L, As ≈ 1 µg/L, Se ≈ 2 µg/L).
Key Topics and Requirements
- Principle: Small aliquots (typically 20 µl) are introduced into a graphite furnace; stepwise heating dries, pyrolyzes and atomizes the sample; absorbance is measured at element-specific wavelengths.
- Sample handling: Preservation by acidification, filtration and digestion procedures for sediments and complex matrices; strict cleaning for ultra-trace work.
- Interferences & mitigation: Matrix effects (e.g., high chloride) can cause analyte loss; recommended mitigations include optimized temperature programs, pyrolytic tubes, chemical modifiers (Pd/Mg, Mg(NO3)2, NH4H2PO4, Ni), standard addition and background correction (including Zeeman correction considerations).
- Calibration & quality control: Preparation of multi-level calibration solutions, blank calibration solutions, and guidance on standard storage lifetimes. Characteristic masses, instrument detection limits and optimum working ranges are specified for a 20 µl volume.
- Apparatus & reagents: Guidance on reagent purity (water grade 1), acids (HNO3, HCl), commercial or prepared standards (1000 mg/L stocks), and argon purge/protective gas.
- Documentation: Required reporting elements, precision data and annexes detailing stock preparation, sediment digestion and example instrument settings.
- Safety note: Users must follow normal laboratory safety and national regulations.
Applications and Who Uses It
- Environmental and public health laboratories performing trace metal analysis in water and sediments.
- Water utilities and wastewater treatment facilities monitoring regulatory compliance and treatment performance.
- Regulatory agencies, environmental consultants and researchers conducting monitoring, source tracking and risk assessment.
- Manufacturers and service providers of AAS instrumentation and chemical modifiers.
Keywords: ISO 15586:2003, water quality, trace elements, graphite furnace AAS, electrothermal atomization, detection limits, chemical modifiers, sediment digestion, sample preservation.
Related Standards
- ISO 3696 (Water for analytical laboratory use)
- ISO 5667 series (Water sampling guidance)
- ISO 15587-1 / 15587-2 (Digestion methods for element determination)
This standard is essential when precise, low-level determination of trace metals in aqueous and sediment matrices is required using graphite furnace atomic absorption spectrometry.
Технические детали
- Технический комитет
- ISO/TC 147/SC 2 - Physical, chemical and biochemical methods
- SKU
- ISO 15586:2003
Похожие стандарты
Стандарты, упомянутые в описании