ISO 15796:2005
Gas analysis — Investigation and treatment of analytical bias
Gas analysis — Investigation and treatment of analytical bias
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 33
- Дата публикации:
- 10 марта 2005 г.
- Издание:
- ISO IS 15796 edition 1 version 1
- ICS:
- 71.040.40
ISO 15796:2005 specifies generic methods for detecting and correcting bias (systematic errors) of analytical procedures for the analysis of gases, using reference gas mixtures or reference analytical procedures, as well as for estimating the correction uncertainty. The main sources of (and parameters affecting) bias of analytical procedures are instrumental drift (time) and matrix interferences (matrix composition). Moreover, bias normally varies with analyte concentration. ISO 15796:2005 therefore establishes protocols for detecting and correcting drift for an analytical system of limited stability, and for investigating and handling bias of a stable analytical system for a specified range of sample composition. These protocols are intended to be used in method development and method validation studies, either separately or sequentially. ISO 15796:2005 specifies procedures for two options, applicable to systematic effects, as follows: 1) tracing the observed pattern of deviations and correcting for their effect, 2) averaging over their effects and increasing the uncertainty, where normally the first option entails lower uncertainty at the expense of higher effort. For the convenience of the user, the methods specified in ISO 15796:2005 are described for procedures of composition analysis, i.e. procedures for measuring the concentration of a specified analyte in a gas mixture. However, they are equally applicable to measurements of physico-chemical properties of a gas or gas mixture relevant to gas analysis, and translation into this subject field is straightforward.
Abstract
Overview - ISO 15796:2005 (Gas analysis - Investigation and treatment of analytical bias)
ISO 15796:2005 provides generic, practical methods for detecting, quantifying and treating analytical bias (systematic error) in gas analysis. It focuses on using reference gas mixtures or reference analytical procedures to demonstrate traceability and either correct bias or account for it in the measurement uncertainty. The standard addresses the main bias sources: instrumental drift, matrix interferences, and the typical dependence of bias on analyte concentration. It is intended for use during method development and method validation.
Key topics and technical requirements
- Bias detection and correction approaches
- Two options: (1) trace and model observed deviations and correct results, or (2) average effects and increase assigned uncertainty. Option (1) generally yields lower uncertainty but requires more effort.
- Instrumental drift
- Procedures for stability monitoring using a drift-control mixture, control charts (Shewhart-style ±1, ±2, ±3 σ limits), and statistical trend tests based on successive differences.
- Initial stability characterization: analyse the control mixture at least 10 times to estimate precision; update control limits only if the system remains stable.
- Use of two distinct drift-correction mixtures to test concentration-invariance of drift and to derive pooled corrections when applicable.
- Matrix interferences and concentration dependence
- Protocols for investigating bias as a function of sample matrix and analyte concentration and for handling local vs extended measuring ranges.
- Uncertainty estimation
- Methods for estimating uncertainty associated with bias corrections and for increasing uncertainty when corrections are not applied.
Applications - who uses ISO 15796:2005
- Analytical laboratories performing gas composition analysis (environmental, industrial emissions, process control).
- Metrology and calibration laboratories that provide reference gas mixtures or reference procedures.
- Instrument manufacturers and method developers validating instruments and calibrations.
- Quality assurance/quality control (QA/QC) teams implementing traceability and uncertainty budgets.
Practical value and SEO keywords
ISO 15796:2005 helps organizations ensure traceable gas measurements, reduce systematic errors through drift correction, and document uncertainty when bias cannot be fully removed. Keywords: ISO 15796:2005, gas analysis, analytical bias, drift correction, reference gas mixtures, matrix interferences, traceability, stability monitoring, measurement uncertainty, method validation.
Related standards (if applicable)
- ISO 14111, ISO/TS 14167 (traceability principles for gas analysis)
- Guide to the Expression of Uncertainty in Measurement (GUM)
- ISO 7504 (gas analysis vocabulary)
- ISO 8258 (control chart tests)
This standard is a practical resource for establishing bias control and demonstrating traceability in gas analysis workflows.
Технические детали
- Технический комитет
- ISO/TC 158 - Analysis of gases
- SKU
- ISO 15796:2005
Похожие стандарты
Стандарты, упомянутые в описании
ISO 14111:1997
ДействующийNatural gas — Guidelines to traceability in analysis
Overview ISO 14111:1997 - "Natural gas - Guidelines to traceability in analysis" provides guidance on implementing metrological traceability in natural‑gas analysis. Rather than prescribing specific…
ISO/TS 14167:2003
ОтменёнGas analysis — General quality assurance aspects in the use of calibration gas mixtures - Guidelines
ISO 7504:2015
ДействующийGas analysis — Vocabulary
Overview ISO 7504:2015 - Gas analysis - Vocabulary is an international standard that defines terminology used in gas analysis, with a primary focus on calibration gas mixtures used for gas measuremen…