ISO 15883-1:2006
Washer-disinfectors — Part 1: General requirements, terms and definitions and tests
Washer-disinfectors — Part 1: General requirements, terms and definitions and tests
- Статус документа:
- Отменён
- Формат:
- Электронный (PDF)
- Количество страниц:
- 70
- Дата публикации:
- 6 апреля 2006 г.
- Издание:
- ISO IS 15883 edition 1 version 1
- ICS:
- 11.080.10
ISO 15883-1:2006 specifies general performance requirements for washer-disinfectors (WD) and their accessories that are intended to be used for cleaning and disinfection of re-usable medical devices and other articles used in the context of medical, dental, pharmaceutical and veterinary practice. It specifies performance requirements for cleaning and disinfection as well as for the accessories which can be required to achieve the necessary performance. The methods and instrumentation required for validation, routine control and monitoring and re-validation, periodically and after essential repairs, are also specified. The requirements for washer-disinfectors intended to process specific loads are specified in subsequent parts of ISO 15883. For washer-disinfectors intended to process loads of two or more different types the requirements of all relevant parts of this standard apply. ISO 15883-1:2006 does not specify requirements intended for machines for use for laundry or general catering purposes. ISO 15883-1:2006 does not include requirements for machines which are intended to sterilize the load, or which are designated as "sterilizers", these are specified in other standards e.g. EN 285. The specified performance requirements of this standard may not ensure the inactivation or removal of the causative agent(s) (prion protein) of transmissible spongiform encephalopathies. ISO 15883-1:2006 may be used by prospective purchasers and manufacturers as the basis of agreement on the specification of a WD. The test methods for demonstration of compliance with the requirements of ISO 15883-1:2006 may also be employed by users to demonstrate continued compliance of the installed WD throughout its working life. Guidance on a routine test programme also is given.
Abstract
Overview
ISO 15883-1:2006 - "Washer-disinfectors - Part 1: General requirements, terms and definitions and tests" defines the general performance requirements for washer-disinfectors (WD) and their accessories used to clean and disinfect reusable medical devices and other articles in medical, dental, pharmaceutical and veterinary settings. It sets out the requirements for cleaning, disinfection, instrumentation and the methods for validation, routine control, monitoring and re‑validation throughout the WD lifetime. This part is the foundational document for the ISO 15883 series and applies unless a later part modifies specific requirements.
Key topics and requirements
- Scope & definitions: Terms and definitions for washer-disinfectors and associated components to ensure consistent interpretation across manufacturers and users.
- Performance requirements: General criteria for cleaning, disinfection, rinsing and drying performance applicable to all WDs.
- Accessories & process chemicals: Requirements for dosing systems and chemicals needed to achieve validated performance.
- Mechanical, safety and control systems: Design, materials, safety, pipework, spray systems, instrumentation, temperature/pressure indicating systems, control and recording equipment.
- Validation & routine testing: Methods and instrumentation for commissioning, performance qualification, periodic re‑validation and tests after essential repairs; guidance on a routine test programme (Annex A).
- Testing for conformity: Detailed test methods including thermometric tests, chemical dosing tests, cleaning efficacy tests and load dryness.
- Contamination assessment: Includes normative annexes for detection of residual proteinaceous contamination (Annex C) and microbiological recovery for water testing (Annex D).
- Limitations: Not intended for laundry or general catering machines; does not cover sterilizers (e.g., EN 285). The standard notes it may not ensure removal/inactivation of prion agents (transmissible spongiform encephalopathies).
Applications and who uses it
ISO 15883-1 is used by:
- Manufacturers to design and certify washer-disinfectors and accessories to meet international performance expectations.
- Purchasers and procurement teams in hospitals, dental clinics, laboratories and veterinary facilities to specify WD requirements.
- Validation specialists and service engineers for commissioning, routine monitoring and re‑validation programmes.
- Infection control professionals and quality managers to verify cleaning efficacy and ensure compliance with validated processes.
Practical uses include creating procurement specifications, performing acceptance testing, establishing routine test programs and documenting compliance across the WD lifecycle.
Related standards
- Other parts of ISO 15883 series (e.g., Part 2 thermal disinfection, Part 4 chemical disinfection for endoscopes, Part 5 test soils)
- IEC 61010-2-045 (safety requirements for washer-disinfectors)
- EN 285 (sterilizer requirements - distinct from washer-disinfectors)
Keywords: ISO 15883-1, washer-disinfectors, washer disinfector validation, cleaning and disinfection, medical device reprocessing, routine control, performance requirements.
Технические детали
- Технический комитет
- ISO/TC 198 - Sterilization of health care products
- SKU
- ISO 15883-1:2006
Похожие стандарты
Стандарты, упомянутые в описании
ISO 15883-6:2011
ОтменёнWasher-disinfectors — Part 6: Requirements and tests for washer-disinfectors employing thermal disinfection f…
Overview ISO 15883-6:2011 - Washer-disinfectors - Part 6 specifies particular requirements and tests for washer-disinfectors employing thermal disinfection intended for cleaning and disinfecting non-…