ISO 16000-19:2012
Indoor air — Part 19: Sampling strategy for moulds
Indoor air — Part 19: Sampling strategy for moulds
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 35
- Дата публикации:
- 31 мая 2012 г.
- Издание:
- ISO IS 16000 edition 1 version 1
- ICS:
- 13.040.20
ISO 16000-19:2012 describes the measurement strategy for the detection of fungi in indoor environments. ISO 16000-19:2012 describes suitable sampling and analysis methods together with a description of the applicability and the interpretation of the measurement results to maximize the comparability of the measured data obtained for a given measurement objective. It does not include details on recording building characteristics or field inspections by qualified professionals which have to take place prior to any microbiological measurement. ISO 16000-19:2012 is not applicable to a detailed description of the building physics- and building-engineering-related procedures applicable to field inspections. The methods and procedures presented do not allow quantitative exposure assessment with regard to the room occupants. The application of ISO 16000-19:2012 presupposes the knowledge of ISO 16000-1.
Abstract
Overview
ISO 16000-19:2012 - Indoor air - Part 19: Sampling strategy for moulds defines a standardized sampling strategy for detecting fungi (moulds) in indoor environments. The standard describes suitable sampling and analysis approaches, applicability and interpretation of results to maximize comparability of measured data for a given measurement objective. It focuses on measurement strategy and methods for mould detection; it does not replace building inspections, building-physics procedures or provide quantitative exposure assessment for occupants. Application of ISO 16000-19 presupposes familiarity with ISO 16000-1 (general sampling strategy).
Key topics and requirements
- Scope and purpose: Guidance to identify indoor mould sources and to standardize sampling to improve data comparability.
- Properties and occurrence: Describes origin, variability and behaviour of mould spores in indoor air (seasonal and site-dependent variability; typical spore size range).
- Sampling and detection methods: Summarizes applicable techniques (e.g., filtration, impaction, culture-based and total spore count approaches - see related parts ISO 16000-16, -17, -18 for method details).
- Measurement strategy: Selection of appropriate procedures based on measurement objectives, site conditions and sample types; planning to reduce sampling stress and preserve biological integrity.
- Quality requirements and uncertainty: Emphasis on quality assurance, documentation and consideration of uncertainty to improve comparability between datasets.
- Informative annexes: Includes guidance on moisture-damage indicators, devices for total spore counts and culturable fungi, and a field inspection reporting template to document sampling and potential mould damage.
- Exclusions: Does not cover recording building characteristics in detail, field inspections by qualified professionals, or engineering procedures related to inspections; not intended for occupant exposure quantification.
Applications and who uses it
ISO 16000-19 is designed for professionals involved in indoor air quality (IAQ) and mould assessment:
- Environmental consultants and industrial hygienists conducting mould investigations
- Analytical laboratories performing airborne fungal analyses
- Facility managers and building owners seeking standardized assessment methods
- Public health officers and regulators requiring comparable sampling protocols
- Building remediation contractors planning investigation and verification sampling
Practical uses include identifying active mould growth sources, planning sampling campaigns, standardizing laboratory reporting and comparing results across sites or over time. Note: prior field inspection by qualified personnel is required before microbiological sampling.
Related standards
- ISO 16000-1 (general sampling strategy)
- ISO 16000-16 (sampling by filtration)
- ISO 16000-17 (culture-based detection)
- ISO 16000-18 (sampling by impaction)
Keywords: ISO 16000-19:2012, indoor air, sampling strategy for moulds, mould sampling, fungal detection, indoor air quality, mould spores, ISO 16000.
Технические детали
- Технический комитет
- ISO/TC 146/SC 6 - Indoor air
- SKU
- ISO 16000-19:2012
Похожие стандарты
Стандарты, упомянутые в описании
BS ISO 16000-16:2008
ДействующийIndoor air. Detection and enumeration of moulds. Sampling by filtration.
BS ISO 16000-17:2008
ДействующийIndoor air. Detection and enumeration of moulds. Culture-based method.
BS ISO 16000-18:2011
ДействующийIndoor air. Detection and enumeration of moulds. Sampling by impaction.
ISO 16000-42:2023
ДействующийIndoor air — Part 42: Measurement of the particle number concentration by condensation particle counters
Overview ISO 16000-42:2023 - "Indoor air - Part 42: Measurement of the particle number concentration by condensation particle counters" provides standardized methods and strategies for measuring the…