ISO 16063-22:2005
Methods for the calibration of vibration and shock transducers — Part 22: Shock calibration by comparison to a reference transducer
Methods for the calibration of vibration and shock transducers — Part 22: Shock calibration by comparison to a reference transducer
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 23
- Дата публикации:
- 13 июня 2005 г.
- Издание:
- ISO IS 16063 edition 1 version 1
- ICS:
- 17.160
ISO 16063-22:2005 specifies the instrumentation and procedures to be used for secondary shock calibration of rectilinear transducers, using a reference acceleration, velocity or force measurement for the time-dependent shock. The methods are applicable in a shock pulse duration range of 0,05 ms to 8,0 ms, and a dynamic range (peak value) of 100 m/s to 100 km/s2 (time-dependent). The methods allow the transducer shock sensitivity (i.e. the relationship between the peak values of the transducer output quantity and the acceleration) to be obtained. These methods are not intended for the calibration of dynamic force transducers used in modal analysis.
Abstract
Overview
ISO 16063-22:2005 - Methods for the calibration of vibration and shock transducers - Part 22: Shock calibration by comparison to a reference transducer - defines instrumentation and procedures for secondary shock calibration of rectilinear transducers (e.g., accelerometers) by comparison to a reference acceleration, velocity or force measurement. The standard covers time-dependent shock pulses with pulse durations from about 0.05 ms to 8.0 ms and a peak dynamic range spanning roughly 100 m/s² to 100 km/s². It establishes how to obtain shock sensitivity (relationship between transducer output peak and acceleration) and provides uncertainty guidance for calibration laboratories requiring traceability (e.g., ISO 9001, ISO/IEC 17025).
Key Topics and Requirements
- Scope and limits: Procedures for secondary shock calibration of rectilinear transducers; not intended for dynamic force transducers used in modal analysis.
- Shock pulse range: Applicable half‑sine and time‑dependent pulses within the specified duration and peak ranges.
- Calibration methods & apparatus: Detailed requirements for anvil shock calibrators (pendulum, dropball, pneumatically operated piston), Hopkinson bar techniques (acceleration, velocity or force comparison), and associated equipment (oscilloscopes, waveform recorders, data processing).
- Mounting and mechanical tolerances: Requirements for polished, flat mounting surfaces (Ra < 1 µm), flatness control (within a few µm), and hole perpendicularity tolerances to preserve reference transducer performance.
- Transducer resonance control: The transducer’s natural period should be less than 0.2 times the half‑sine pulse duration to avoid resonance-induced errors.
- Uncertainty of measurement: Expanded relative uncertainties are specified (coverage factor k = 2, ≈95 %). Typical guidance: pendulum, dropball and pneumatic methods can achieve uncertainties around 5 % under reference conditions; Hopkinson bar methods have different typical uncertainty levels depending on comparison technique.
- Data processing & reporting: Procedures for time‑history acquisition, signal processing (filtering, windows) and standardized reporting of calibration results.
Applications
- Calibration and validation of shock accelerometers and shock transducers for industries such as aerospace, automotive, electronics, defense and research.
- Establishing traceable shock sensitivity for test equipment used in component drop testing, shock survivability, and environmental qualification.
- Routine secondary calibration services in accredited metrology laboratories (ISO/IEC 17025).
Who will use this standard
- Calibration laboratories and metrology institutes
- Transducer manufacturers and test houses
- Quality managers and engineers responsible for shock testing and traceability
Related standards
- ISO 16063 series (Part 1, Part 13, Part 21, etc.)
- ISO 2041 (vibration and shock vocabulary)
- ISO 5347-22 (resonance testing)
- ISO 18431-2 (signal processing - time domain windows)
Keywords: ISO 16063-22:2005, shock calibration, reference transducer, accelerometer calibration, pendulum calibrator, dropball, Hopkinson bar, uncertainty, traceability, ISO 17025.
Технические детали
- Технический комитет
- ISO/TC 108 - Mechanical vibration, shock and condition monitoring
- SKU
- ISO 16063-22:2005
Похожие стандарты
Стандарты, упомянутые в описании
ISO/TS 54001:2019
ДействующийQuality management systems — Particular requirements for the application of ISO 9001:2015 for electoral organ…
Overview ISO/TS 54001:2019 - Quality management systems - Particular requirements for the application of ISO 9001:2015 for electoral organizations at all levels of government - provides sector-specif…
BS EN ISO/IEC 17025:2017
ДействующийGeneral requirements for the competence of testing and calibration laboratories.
BS ISO 20411:2018
ДействующийSurface chemical analysis. Secondary ion mass spectrometry. Correction method for saturated intensity in sing…
ISO 5347-22:1997
ДействующийMethods for the calibration of vibration and shock pick-ups — Part 22: Accelerometer resonance testing — Gene…
Overview ISO 5347-22:1997 defines general methods for accelerometer resonance testing, a critical process in the calibration of vibration and shock pick-ups. This international standard provides deta…