ISO 16170:2016
In situ test methods for high efficiency filter systems in industrial facilities
In situ test methods for high efficiency filter systems in industrial facilities
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 36
- Дата публикации:
- 27 июня 2016 г.
- Издание:
- ISO IS 16170 edition 1 version 1
- ICS:
- 91.140.30
ISO 16170:2016 specifies in situ test methods for high efficiency particulate air filters used to limit releases towards the environment (e.g. from nuclear facilities or facilities with aerosol toxic or biological releases). This applies where installations of these filters are used to clean effluent air before discharge to the environment from industrial (including nuclear) installations where toxic/radioactive/biological materials are handled or processed. It excludes the application already covered by ISO 14644‑3. The scope of ISO 16170:2016 includes detail of two methods, either of which applies to the periodic testing of high efficiency filters which are used in demanding applications aiming at protecting the environment, such as the nuclear industry. In the case of nuclear applications, ISO 16170:2016 is applicable to installations covered by ISO 17873 (applications other than nuclear reactors) and ISO 26802 (nuclear reactors). The two reference methods specified in ISO 16170:2016 are not equivalent, but related to, the requirements to be addressed by the test results. The choice of which of the two methods is adopted in any specific case depends on whether the outcome requires an integrity test or a statutory efficiency accountancy test. For industries handling or processing radioactive or toxic materials giving rise to a risk of possible release, the main goal of the tests is to confirm that the filter installation is fit for purpose. In the case of integrity tests (Annex B), this is to confirm that no significant leakage of toxic aerosols through the filter installation is possible. In the case of efficiency accountancy tests (Annex C), the test is designed to make an accurate measurement of decontamination factor with respect to the MPPS size range of particles. The reference method described in Annex B (integrity test) requires a test aerosol of dispersed oil particles mainly submicrometre in size range, which is stable during the test procedure and compatible with other installation components. Particle concentrations are measured in real time by light scattering instrumentation (optical detectors). The reference method described in Annex C (efficiency accountancy test) requires a test aerosol of particles having a narrow size range centred on MPPS size range for HEPA filter media. Their concentration both upstream and downstream the filters is measured by fluorimetric analysis of aqueous solution obtained by washing the membrane sampling filters. It should be noted that the requirements for an efficiency accountancy test also cover the requirements of an integrity test, which is considered to be a minimum requirement. Test methods developed in ISO 16170:2016 do not cover the other in situ performance requirements, such as mechanical resistance, bursting resistance or humidity resistance. Specific systems operating at high temperature or with specific gaseous effluents might require specific test methods. The engineering design of HEPA and ULPA filter installations does not fall within the scope of ISO 16170:2016. NOTE In the field of filters for general ventilation applications, ISO 29462 is a detailed and comprehensive description of a method which uses scanning and particle counting methods to evaluate the performance of a filter in terms of particle grade efficiency, as well as pressure drop. Such a method and procedure would not be applicable in those nuclear installations where quantification of the decontamination factor at MPPS size is needed.
Abstract
Overview - what ISO 16170:2016 covers
ISO 16170:2016 specifies standardized in situ test methods for high efficiency particulate air (HEPA) and ultra-low penetration air (ULPA) filter systems installed to protect the environment from toxic, biological or radioactive aerosol releases - for example in nuclear and other high‑hazard industrial facilities. The standard defines two reference in‑place test methods (integrity test and efficiency accountancy test), requirements for test equipment, sampling, data interpretation and reporting, plus preparatory and personnel qualifications needed for periodic verification of filter installations.
Key technical topics and requirements
- Two reference methods (not equivalent):
- Integrity test (Annex B) - uses a dispersed oil aerosol (mainly submicrometre) as a challenge; particle concentrations are measured in real time by light‑scattering optical detectors to detect significant leakage.
- Efficiency accountancy test (Annex C) - uses a narrow‑size aerosol centered on the MPPS (Most Penetrating Particle Size) for HEPA media; upstream/downstream concentrations are obtained by membrane sampling and fluorimetric analysis (e.g., uranine wash) to calculate the decontamination factor precisely.
- Aerosol choices: solid or liquid, monodisperse or polydisperse, selected to meet the test objective.
- Prerequisites and preparatory conditions: filter initial characterization, choice of injection and sampling locations, ventilation and climatic conditions, apparatus selection and calibration, health and safety measures, and qualification of test personnel.
- Test sequence and reporting: defined procedures for aerosol injection, sampling set‑up, monitoring upstream/downstream concentrations, calculations, and formal test reports.
- Scope limits: excludes engineering design of filter systems and other in‑situ performance aspects (mechanical/bursting resistance, humidity or high‑temperature resistance). It also excludes applications already covered by ISO 14644‑3.
Practical applications and who uses it
- Primary use: periodic verification that installed HEPA/ULPA systems are fit for purpose and will prevent environmental release of hazardous aerosols.
- Typical users:
- Nuclear facility ventilation engineers and safety specialists (linked to ISO 17873 and ISO 26802)
- Environmental compliance teams in chemical, biological or radioactive material processing plants
- Facilities managers, test laboratories and contractors performing statutory efficiency accountancy or integrity testing
- Health & safety and regulatory inspectors requiring documented in‑place performance evidence
- Benefits: clear, auditable methodology for detecting leaks, quantifying decontamination factors at MPPS, and supporting safety cases and regulatory compliance.
Related standards
- ISO 29463 (filter classification and lab testing)
- ISO 14644‑3 (cleanroom in situ tests - excluded application)
- ISO 17873, ISO 26802 (nuclear ventilation criteria)
- ISO 2889 (sampling airborne radioactive materials)
Keywords: ISO 16170, in situ test methods, HEPA, ULPA, integrity test, efficiency accountancy, MPPS, decontamination factor, dispersed oil aerosol, uranine, fluorimetric analysis, light scattering.
Технические детали
- Технический комитет
- ISO/TC 142 - Cleaning equipment for air and other gases
- SKU
- ISO 16170:2016
Похожие стандарты
Стандарты, упомянутые в описании
BS EN ISO 14644-3:2019
ДействующийCleanrooms and associated controlled environments. Test methods.
ISO 17873:2004
ДействующийNuclear facilities — Criteria for the design and operation of ventilation systems for nuclear installations o…
Overview ISO 17873:2004 provides essential criteria for the design and operation of ventilation systems in nuclear facilities other than nuclear reactors. Developed by the International Organization…
BS ISO 26802:2010
ДействующийNuclear facilities. Criteria for the design and the operation of containment and ventilation systems for nucl…
ISO 29463-5:2011
ОтменёнHigh-efficiency filters and filter media for removing particles in air — Part 5: Test method for filter eleme…
ISO 2889:2023
ДействующийSampling airborne radioactive materials from the stacks and ducts of nuclear facilities
Overview ISO 2889:2023 - Sampling airborne radioactive materials from the stacks and ducts of nuclear facilities provides performance-based criteria and practical recommendations for the design, use…