ISO 16900-3:2012
Respiratory protective devices — Methods of test and test equipment — Part 3: Determination of particle filter penetration
Respiratory protective devices — Methods of test and test equipment — Part 3: Determination of particle filter penetration
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 10
- Дата публикации:
- 29 октября 2012 г.
- Издание:
- ISO IS 16900 edition 1 version 1
- ICS:
- 13.340.30
ISO 16900-3:2012 specifies the test methods for particle filter penetration of separate or integral filters for respiratory protective devices.
Abstract
Overview
ISO 16900-3:2012 - "Respiratory protective devices - Methods of test and test equipment - Part 3: Determination of particle filter penetration" specifies standardized test methods to determine particle filter penetration for separate or integral filters used in respiratory protective devices (RPDs). The standard defines the test principle, required apparatus, aerosols, test procedures (short-term, full exposure, storage-after-exposure), data reporting and measurement uncertainty to support consistent, reproducible filter performance evaluation.
Key topics and technical requirements
- Test principle: A challenge aerosol with known characteristics is passed through the filter; penetration (%) = (downstream concentration / upstream concentration) × 100.
- Reference aerosols:
- Sodium chloride (NaCl) - neutralized to Boltzmann charge equilibrium; number median diameter between 0.06 µm and 0.10 µm, geometric SD 1.4–1.8; mass concentration 8–35 mg/m3. NaCl is analyzed by flame photometry (sodium emission at 589 nm).
- Paraffin oil - not neutralized; number median diameter between 0.16 µm and 0.21 µm, geometric SD 1.4–1.8; mass concentration 15–35 mg/m3. Measured by forward light-scattering photometer (effective scattering angle up to 45°).
- Apparatus modules: aerosol generator, flow control, filter test chamber, and aerosol detector. The test chamber must expose the entire filter area uniformly and be leak-tight.
- Environmental and tolerances: Ambient testing temperature typically between 16°C and 32°C and relative humidity around 50% ±30%; nominal values subject to ±5% tolerance unless otherwise specified.
- Test procedures: Includes short-term penetration, full-exposure penetration, and storage-after-exposure tests; upstream and downstream aerosol concentrations are monitored to calculate percent penetration.
- Calibration and measurement uncertainty: Detectors must be calibrated for the aerosol type and concentration range; the standard requires uncertainty estimation and provides normative guidance (see Annex A).
Applications and who uses this standard
- Manufacturers of respirators and filter cartridges use ISO 16900-3 to validate and demonstrate particle filtration performance during product development and quality control.
- Testing laboratories and certification bodies apply the methods to generate reproducible penetration data for compliance with RPD performance standards.
- Occupational health professionals, procurement teams, and regulators rely on standardized penetration testing to compare filter efficiencies and make informed selection decisions for workplace respiratory protection.
- Practical uses include performance classification, R&D of new filter media, batch release testing, and verification of claims (e.g., filter efficiency vs. particle size).
Related standards
- ISO 16900 series (other parts for leakage, breathing resistance, gas filter tests)
- ISO 17420 (RPD performance standards referenced in application)
- ISO 16972 (terms and definitions)
- ISO 21748 (guidance on measurement uncertainty)
- ISO 15900 (electrical mobility methods for particle sizing)
Keywords: ISO 16900-3, particle filter penetration, respiratory protective devices, filter penetration test, NaCl aerosol, paraffin oil aerosol, aerosol detector, test methods.
Технические детали
- Технический комитет
- ISO/TC 94/SC 15 - Respiratory protective devices
- SKU
- ISO 16900-3:2012
Похожие стандарты
Стандарты, упомянутые в описании
BS ISO 16900-3:2012
ДействующийRespiratory protective devices. Methods of test and test equipment. Determination of particle filter penetrat…
ISO 16900-13:2015
ДействующийRespiratory protective devices — Methods of test and test equipment — Part 13: RPD using regenerated breathab…
Overview - ISO 16900-13:2015 (Respiratory protective devices) ISO 16900-13:2015 defines consolidated laboratory test methods for respiratory protective devices (RPD) that use regenerated breathable g…