ISO 17089-2:2012
Measurement of fluid flow in closed conduits - Ultrasonic meters for gas — Part 2: Meters for industrial applications
Measurement of fluid flow in closed conduits - Ultrasonic meters for gas — Part 2: Meters for industrial applications
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 38
- Дата публикации:
- 24 сентября 2012 г.
- Издание:
- ISO IS 17089 edition 1 version 1
- ICS:
- 17.120.10
This part of ISO 17089 specifies requirements and recommendations for ultrasonic gas meters (USMs), which utilize acoustic signals to measure the flow in the gaseous phase in closed conduits. This part of ISO 17089 is applicable to transit time USMs and is focused towards industrial flow measurement. Included are meters comprising meter bodies as well as meters with field-mounted transducers. There are no limits on the size of the meter. It can be applied to the measurement of almost any type of gas; such as but not limited to air, hydrocarbon gases, and steam. This part of ISO 17089 specifies performance, calibration (when required), and output characteristics of USMs for gas flow measurement and deals with installation conditions. NOTE It is possible that national or other regulations apply which can be more stringent than those in this part of ISO 17089.
Abstract
Overview
ISO 17089-2:2012 - "Measurement of fluid flow in closed conduits - Ultrasonic meters for gas - Part 2: Meters for industrial applications" defines requirements and recommendations for transit‑time ultrasonic gas meters (USMs) used in industrial flow measurement. The standard covers meters with integrated meter bodies and field‑mounted transducers, for essentially any gas (air, hydrocarbon gases, steam, etc.), and sets out performance, calibration, output, installation and verification expectations for industrial (Class 3 and 4) applications. It also notes that national regulations may be more stringent.
Key topics and requirements
- Principles of measurement
- Transit‑time USM operation and acoustic path types (axial, diametrical, chordal).
- Factors affecting USM performance (gas properties, pressure/temperature, flow profile).
- Meter characteristics
- Performance indications, operating conditions and classification (typical Class 3: utilities/process; Class 4: flare/vent).
- Mechanical requirements: meter body, connections, ultrasonic ports, pressure tappings, anti‑roll, flow conditioners and markings.
- Transducer, electronics, firmware/software requirements and diagnostic capabilities.
- Performance, uncertainty and calibration
- Requirements for performance specifications, repeatability, resolution and maximum peak‑to‑peak error.
- Flow test and calibration procedures, static leakage and pressure testing, dimensional and dynamic testing.
- In‑situ verification and meter diagnostics to support automated condition monitoring.
- Installation and handling
- Installation conditions, flow profile considerations, handling and transportation guidance to maintain measurement integrity.
- Testing and verification
- On‑site diagnostics, in‑situ verification methods and guidance for dynamic testing under flowing conditions.
Practical applications and users
ISO 17089-2 is intended for engineers and organizations involved in industrial gas flow measurement, including:
- Plant and process engineers specifying flowmeters for utilities and process control.
- Instrumentation and metering engineers responsible for selection, installation and calibration of ultrasonic gas meters.
- Calibration laboratories and test facilities conducting flow verification and acceptance testing.
- Operators measuring vent, flare or process gases where robust diagnostics and wide rangeability and low pressure loss are required. Benefits of applying ISO 17089-2 include improved measurement repeatability, reduced pressure drop, better handling of pulsating flows, and standardized diagnostics for operational assurance.
Related standards
- ISO 17089-1 (meters for custody transfer and allocation measurement)
- ISO 4006 (vocabulary and symbols for fluid flow in closed conduits)
- Referenced standards on thermodynamic and metering terms cited within ISO 17089-2
Keywords: ISO 17089-2:2012, ultrasonic gas meters, transit-time USM, industrial flow measurement, calibration, diagnostics, installation requirements, meter classification.
Технические детали
- Технический комитет
- ISO/TC 30/SC 5 - Velocity and mass methods
- SKU
- ISO 17089-2:2012
Похожие стандарты
Упомянутые в описании и другие стандарты ISO
BS ISO 17089-1:2019
ДействующийMeasurement of fluid flow in closed conduits. Ultrasonic meters for gas. Meters for custody transfer and allo…
ISO 4006:1991
ДействующийMeasurement of fluid flow in closed conduits — Vocabulary and symbols
Overview ISO 4006:1991 - Measurement of fluid flow in closed conduits - Vocabulary and symbols - is an ISO international standard that defines recommended terms and corresponding symbols used in the…
ISO 8212:1986
ОтменёнSoaps and detergents — Techniques of sampling during manufacture
Overview Standard Reference: ISO 8212:1986 Title: Soaps and detergents - Techniques of sampling during manufacture ISO 8212:1986 defines standardized techniques for taking representative samples of s…
ISO 20662:2020
ДействующийShips and marine technology — Hopper dredger supervisory and control systems
Overview ISO 20662:2020 - Ships and marine technology: Hopper dredger supervisory and control systems (HD‑SCS) - specifies the components, structure, general requirements, and functional requirements…
ISO 3021:2023
ДействующийAdventure tourism — Hiking and trekking activities — Requirements and recommendations
Overview ISO 3021:2023 - Adventure tourism: Hiking and trekking activities - Requirements and recommendations defines safety-focused requirements and recommendations for hiking and trekking offered a…
ISO 3826-2:2008
ДействующийPlastics collapsible containers for human blood and blood components — Part 2: Graphical symbols for use on l…
Overview ISO 3826-2:2008 - "Plastics collapsible containers for human blood and blood components - Part 2: Graphical symbols for use on labels and instruction leaflets" defines a system of internatio…
ISO/IEC 24730-1:2014
ДействующийInformation technology — Real-time locating systems (RTLS) — Part 1: Application programming interface (API)
Overview ISO/IEC 24730-1:2014 specifies the Application Programming Interface (API) for Real‑Time Locating Systems (RTLS). The standard defines a minimal, interoperable boundary that lets application…
ISO 8668-5:1992
ДействующийAircraft — Terminal junction systems — Part 5: Detail specification for type 3 system
Overview - ISO 8668-5:1992 (Aircraft terminal junction systems, Type 3) ISO 8668-5:1992 defines the detail specification for Type 3 Terminal Junction Systems (TJS) used in aircraft electrical install…