ISO 17511:2020
In vitro diagnostic medical devices — Requirements for establishing metrological traceability of values assigned to calibrators, trueness control materials and human samples
In vitro diagnostic medical devices — Requirements for establishing metrological traceability of values assigned to calibrators, trueness control materials and human samples
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 54
- Дата публикации:
- 24 апреля 2020 г.
- Издание:
- ISO IS 17511 edition 2 version 1
- ICS:
- 11.100.10
This document specifies technical requirements and documentation necessary to establish metrological traceability of values assigned to calibrators, trueness control materials and human samples for quantities measured by IVD MDs. The human samples are those intended to be measured, as specified for each IVD MD. Metrological traceability of values for quantities in human samples extends to the highest available reference system component, ideally to RMPs and certified reference materials (CRMs). All parties having a role in any of the steps described in a calibration hierarchy for an IVD MD are subject to the requirements described. These parties include but are not limited to manufacturers (of IVD MDs), RMP developers (see ISO 15193), RM producers (see ISO 15194), and reference/calibration laboratories (see ISO 15195) supporting calibration hierarchies for IVD MDs. NOTE 1 Producers of RMs intended for use in standardization or calibration of IVD MDs include commercial and non-commercial organizations producing RMs for use by many end-users of IVD MDs and/or calibration laboratories, or for use by a single end-user medical laboratory, as in the case of a measurement standard (calibrator) intended to be used exclusively for calibration of a laboratory-developed MP. This document is applicable to: a) all IVD MDs that provide measurement results in the form of numeric values, i.e. rational (ratio) and/or differential (interval) scales, and counting scales. b) IVD MDs where the measurement result is reported as a qualitative value established with a ratio of two measurements (i.e. the signal from a specimen being tested and the signal from a RM with a specified concentration or activity at the cut-off), or a counting scale, with corresponding decision threshold(s). This also includes IVD MDs where results are categorized among ordinal categories based on pre-established quantitative intervals for a quantity. c) RMs intended for use as trueness control materials for verification or assessment of calibration of IVD MDs, i.e. some commutable CRMs and some external quality assessment (EQA) materials (if so indicated in the RM's intended use statement). d) IVD MD-specific calibrators and trueness control materials with assigned values, intended to be used together with a specified IVD MD. e) IVD MDs as described in a) and b), where no end-user performed calibration is required (i.e. when the manufacturer performs a factory calibration of the IVD MD). This document is not applicable to: a) calibrators and trueness control materials for IVD MDs which, due to their formulation, are known to have zero amount of measurand; b) control materials that are used only for internal quality control purposes in medical laboratories to assess the imprecision of an IVD MD, either its repeatability or reproducibility, and/or for assessing changes in IVD MD results compared to a previously established calibration condition; c) control materials that are used only for internal quality control purposes in medical laboratories and which are supplied with intervals of suggested acceptable values that are not metrologically traceable to higher order reference system components; d) properties reported as nominal scales and ordinal scales, where no magnitude is involved. NOTE 2 Nominal scales are typically used to report e.g. identity of blood cell types, microorganism types, identity of nucleic acid sequences, identity of urine particles. NOTE 3 Ordinal scales are often applied to results differentiated into dichotomous groupings (e.g. ?sick' vs. ?healthy'), and occasionally to results differentiated into non-dichotomous categories where the result categories are rank-ordered but the rank-ordered categories cannot be differentiated in terms of relative degree of difference, e.g. negative, +1, +2, +3 for grading of presence of haemoglobin in urine specimens by visual observation.
Abstract
Overview
ISO 17511:2020 specifies the technical requirements and documentation needed to establish metrological traceability of values assigned to calibrators, trueness control materials and human samples used with in vitro diagnostic (IVD) medical devices. It defines how measurement results (numeric, counting, and some qualitative results derived from quantitative cut‑offs) should be linked through a documented calibration hierarchy up to the highest available reference system (ideally reference measurement procedures (RMPs) and certified reference materials (CRMs)). The standard applies to manufacturers, RM producers and reference/calibration laboratories involved in value assignment for IVD MDs.
Key topics and requirements
- Scope and applicability: Applies to IVD MDs reporting rational, interval or counting scale results, and some qualitative/ordinal results derived from quantitative thresholds; excludes materials with zero measurand or internal QC-only controls without traceable values.
- Definition of the measurand: Clear, documented specification of what is being measured is required for traceability.
- Calibration hierarchy: Establish and document the chain of value transfer from end‑user calibrators up to RMPs/CRMs or the highest available reference.
- Reference materials (RMs) and calibrators: Selection criteria, characteristics to document, and requirements for higher order RMs (see ISO 15194) including commutability assessment and exceptions.
- Uncertainty: Specification of maximum allowable expanded measurement uncertainty (Umax(y)) and methods to estimate and document uncertainty of assigned values.
- Validation: Validation strategies and test designs for demonstrating metrological traceability of end‑user calibrators and changes to calibrators or methods.
- Documentation and responsibilities: Manufacturer obligations to maintain and provide calibration hierarchy documentation; responsibilities of RMP developers (ISO 15193), RM producers (ISO 15194) and reference/calibration labs (ISO 15195).
- Model calibration hierarchies: Practical cases described (with RMPs and primary RMs, international calibrators, harmonisation protocols, or manufacturer‑defined internal RMs).
Applications and who uses it
ISO 17511:2020 is used by:
- IVD manufacturers to design, validate and document calibration systems and factory calibrations.
- Reference and calibration laboratories to support value assignment and calibration chains.
- RM and CRM producers to supply materials suitable for traceability (including commutability information).
- Clinical laboratories and EQA providers to understand traceability claims and evaluate comparability of results.
- Regulators and assessors evaluating metrological traceability evidence for device approval and quality programs.
Practical benefits include improved comparability of lab results across methods and sites, clearer uncertainty reporting, and stronger evidence for regulatory compliance and clinical decision‑making.
Related standards
- ISO 15193 - Reference measurement procedures (RMPs) context
- ISO 15194 - Production and certification of reference materials (RMs/CRMs)
- ISO 15195 - Reference and calibration laboratory requirements
Keywords: ISO 17511:2020, metrological traceability, IVD medical devices, calibrators, trueness control materials, calibration hierarchy, commutability, reference measurement procedures, certified reference materials, uncertainty.
Технические детали
- Технический комитет
- ISO/TC 212 - Clinical laboratory testing and in vitro diagnostic test systems
- SKU
- ISO 17511:2020
Похожие стандарты
Стандарты, упомянутые в описании
BS EN ISO 15194:2009
ДействующийIn vitro diagnostic medical devices. Measurement of quantities in samples of biological origin. Requirements…
ISO 15193:2009
ОтменёнIn vitro diagnostic medical devices — Measurement of quantities in samples of biological origin — Requirement…
Overview ISO 15193:2009 - "In vitro diagnostic medical devices - Measurement of quantities in samples of biological origin - Requirements for content and presentation of reference measurement procedu…