ISO 18242:2016
Cardiovascular implants and extracorporeal systems — Centrifugal blood pumps
Cardiovascular implants and extracorporeal systems — Centrifugal blood pumps
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 10
- Дата публикации:
- 15 августа 2016 г.
- Издание:
- ISO IS 18242 edition 1 version 1
- ICS:
- 11.040.40
ISO 18242:2016 specifies requirements for sterile, single-use, extracorporeal centrifugal blood pumps, whether coated, non-surface modified, or surface-modified, intended for producing blood flow during extracorporeal circulation. Such blood flow is most commonly used to provide systemic perfusion during cardiopulmonary bypass, but also has applications for veno-venous bypass, kinetic-assisted venous drainage, or extracorporeal membrane oxygenation. It does not apply to - centrifugal pumps used as ventricular assist devices, and - other components of extracorporeal circuits (e.g. blood tubing, pump console/driver).
Abstract
Overview
ISO 18242:2016 - Cardiovascular implants and extracorporeal systems - Centrifugal blood pumps - specifies requirements and test methods for sterile, single‑use extracorporeal centrifugal blood pumps (coated, surface‑modified or not) intended to produce blood flow during extracorporeal circulation. The standard covers devices used for cardiopulmonary bypass, veno‑venous bypass, kinetic‑assisted venous drainage, and extracorporeal membrane oxygenation (ECMO). It does not apply to centrifugal pumps used as ventricular assist devices (VADs) or to other extracorporeal components such as tubing or pump consoles.
Key topics and technical requirements
- Scope & definitions: Clear terms for centrifugal blood pump, blood pathway, operating variables, blood cell damage, normalized index of hemolysis (NIH), etc.
- Biological requirements:
- Sterility and non‑pyrogenicity verification per sterilization and biocompatibility standards.
- Biocompatibility of all blood‑contacting parts (refer to ISO 10993 series).
- Physical integrity:
- Blood pathway leak test: 1.5× manufacturer’s max pressure or 152 kPa if unspecified; visual inspection for minimum 6 hours.
- Prime volume: measured from inlet tip to outlet tip across operating range.
- Connector integrity: must withstand a 15 N pull for 15 s; common connector inner diameters noted (4.8, 6.3, 9.5, 12.7 mm) and ISO 7199 compatibility.
- Performance testing:
- Hydraulic performance: measure flow vs pressure differential across RPM range; test at 37 °C ± 1 °C using blood analogue or anticoagulated blood.
- Blood cell damage: in‑vitro tests with anticoagulated whole blood measuring plasma‑free hemoglobin, platelet and white blood cell counts at defined time points (pre, 30, 180, 360 min); NIH and hemolysis reporting expected.
- Bearing durability: worst‑case conditions at max RPM and clinical backpressure; operate for minimum of 6 hours (or manufacturer‑specified).
- Shelf life: accelerated aging of finished, packaged devices to demonstrate rated shelf life.
- Manufacturer information: required labeling and performance parameters to enable device comparison.
Applications and users
ISO 18242:2016 is used by:
- Medical device manufacturers to design, verify and document centrifugal pump safety and performance.
- Test laboratories to perform standardized hydraulic, hemolysis and durability testing.
- Regulatory authorities and notified bodies for evaluation of extracorporeal single‑use pumps.
- Clinical engineers and procurement teams who compare pump performance and labeling for purchase or clinical selection.
Related standards
Normative references commonly used with ISO 18242 include:
- ISO 10993 series (biocompatibility)
- ISO 11135, ISO 11137, ISO 17665 (sterilization)
- ISO 11607 (packaging)
- ISO 11658 (blood/tissue contact surface modifications)
- ASTM F1830 (selection of blood for in‑vitro pump testing)
Keywords: ISO 18242:2016, centrifugal blood pumps, extracorporeal, cardiopulmonary bypass, ECMO, biocompatibility, hydraulic performance, hemolysis, NIH, medical device testing.
Технические детали
- Технический комитет
- ISO/TC 150/SC 2 - Cardiovascular implants and extracorporeal systems
- SKU
- ISO 18242:2016
Похожие стандарты
Стандарты, упомянутые в описании
ISO 10993-12:2012
ОтменёнBiological evaluation of medical devices — Part 12: Sample preparation and reference materials
ISO 7199:2024
ДействующийCardiovascular implants and artificial organs — Blood-gas exchangers (oxygenators)
Overview ISO 7199:2024 - "Cardiovascular implants and artificial organs - Blood‑gas exchangers (oxygenators)" specifies requirements for sterile, single‑use extracorporeal oxygenators used for oxygen…
BS EN ISO 182-4:2000
ДействующийPlastics. Determination of the tendency of compounds and products based on vinyl chloride homopolymers and co…
ISO 11135:2014
ДействующийSterilization of health-care products — Ethylene oxide — Requirements for the development, validation and rou…
Overview ISO 11135:2014 - Sterilization of health‑care products - Ethylene oxide specifies the requirements for the development, validation and routine control of an ethylene oxide (EO) sterilization…
ISO 11137-2:2013
ДействующийSterilization of health care products — Radiation — Part 2: Establishing the sterilization dose
Overview ISO 11137-2:2013 - “Sterilization of health care products - Radiation - Part 2: Establishing the sterilization dose” specifies validated methods to determine the minimum radiation dose requi…
ISO 17665:2024
ДействующийSterilization of health care products — Moist heat — Requirements for the development, validation and routine…
Overview - ISO 17665:2024 (Moist heat sterilization) ISO 17665:2024, "Sterilization of health care products - Moist heat - Requirements for the development, validation and routine control of a steril…
ISO 11607-2:2019
ДействующийPackaging for terminally sterilized medical devices — Part 2: Validation requirements for forming, sealing an…
Overview ISO 11607-2:2019 - Packaging for terminally sterilized medical devices - Part 2: Validation requirements for forming, sealing and assembly processes - specifies requirements for the developm…