ISO 19232-4:2013
Non-destructive testing — Image quality of radiographs — Part 4: Experimental evaluation of image quality values and image quality tables
Non-destructive testing — Image quality of radiographs — Part 4: Experimental evaluation of image quality values and image quality tables
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 3
- Дата публикации:
- 13 июня 2013 г.
- Издание:
- ISO IS 19232 edition 2 version 1
- ICS:
- 19.100
ISO 19232-4:2013 gives instructions for the determination of image quality values and image quality tables. If the IQI requirements specified in ISO 19232‑3 cannot be used because, for example, the absorption coefficients of the IQI material and the inspected material differ by more than 30 %, test exposures are necessary to determine acceptance of image quality values. The image quality values achieved by the test exposures are required for all exposures made under the same radiographic conditions.
Abstract
Overview
ISO 19232-4:2013 is part of the ISO 19232 series, addressing non-destructive testing (NDT) and the image quality of radiographs. Specifically, this standard focuses on the experimental evaluation of image quality values and the creation of image quality tables for radiographic testing. ISO 19232-4:2013 provides a practical framework for situations where conventional requirements for image quality indicators (IQIs), as defined in ISO 19232-3, cannot be applied due to significant differences in absorption coefficients between IQI materials and the tested object.
This standard gives guidance for conducting test exposures and establishing image quality tables under varying radiographic conditions, ensuring reliable and consistent assessment of radiographic image quality in industrial applications.
Key Topics
- Image Quality Indicator (IQI) Use: Defines the use and significance of IQIs-devices with graded elements (such as wires or steps)-to measure radiographic image quality.
- Image Quality Value (IQV) Determination: Instructions for experimental procedures to establish the minimum detectable detail in a radiograph.
- Image Quality Table Creation: Directions for developing tables correlating minimum image quality values to different penetrated thickness ranges.
- Test Exposure Methodology: Outlines how to perform experimental test exposures when standard IQI criteria do not apply, including the repetition of tests for consistent results.
- Acceptance Criteria: Details the process for accepting image quality values based on repeated, reproducible measurements.
- Application Scope: Applicability when the absorption coefficient of the IQI deviates significantly (by more than 30%) from the inspected material.
Applications
ISO 19232-4:2013 is essential for various industries relying on radiographic testing to ensure material integrity and safety. Its primary applications include:
- Industrial Radiography: Used across sectors such as aerospace, automotive, construction, and energy to validate the quality of welds, castings, and structural components.
- Customized Testing Conditions: Enables radiographic testing under non-standard conditions where material properties require experimental evaluation rather than routine application of generalized indicators.
- Development of Inspection Protocols: Supports the creation of customized acceptance criteria and image quality tables for specific materials and geometries, enhancing reliability in critical assessments.
- Quality Assurance in Manufacturing: Ensures traceability and repeatability in radiographic image evaluation, which is vital for organizations needing to meet regulatory, safety, and quality standards.
Related Standards
For a comprehensive approach to image quality in radiographic testing, consider the following ISO standards alongside ISO 19232-4:2013:
- ISO 19232-1: Determines image quality value using wire-type IQIs.
- ISO 19232-2: Determines image quality value using step/hole-type image quality indicators.
- ISO 19232-3: Defines radiographic image quality classes and essential acceptance criteria.
- ISO 19232-5: Specifies the determination of image unsharpness using duplex wire-type IQIs.
- ISO 5579: Lays out the basic rules for radiographic testing of metallic materials using film and X- or gamma rays.
By implementing ISO 19232-4:2013, organizations utilize a standardized, systematic method for evaluating and documenting image quality in radiographic NDT, especially in cases that fall outside standard IQI application, ensuring both compliance and operational excellence.
Технические детали
- Технический комитет
- ISO/TC 135/SC 5 - Radiographic testing
- SKU
- ISO 19232-4:2013
Похожие стандарты
Стандарты, упомянутые в описании
BS EN ISO 19232-1:2013
ДействующийNon-destructive testing. Image quality of radiographs. Determination of the image quality value using wire-ty…
BS EN ISO 19232-3:2025
ДействующийNon-destructive testing. Image quality of radiographs. Minimum image quality values.
BS EN ISO 19232-2:2013
ДействующийNon-destructive testing. Image quality of radiographs. Determination of the image quality value using step/ho…
BS EN ISO 19232-5:2018
ДействующийNon-destructive testing. Image quality of radiographs. Determination of the image unsharpness and basic spati…
ISO 5579:2013
ДействующийNon-destructive testing — Radiographic testing of metallic materials using film and X- or gamma rays — Basic…
Overview ISO 5579:2013 - "Non‑destructive testing - Radiographic testing of metallic materials using film and X‑ or gamma rays - Basic rules" defines the fundamental rules and recommended techniques…