ISO 21003-5:2008
Multilayer piping systems for hot and cold water installations inside buildings — Part 5: Fitness for purpose of the system
Multilayer piping systems for hot and cold water installations inside buildings — Part 5: Fitness for purpose of the system
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 9
- Дата публикации:
- 30 июня 2008 г.
- Издание:
- ISO IS 21003 edition 1 version 1
- ICS:
- 23.040.01
ISO 21003-5:2008 specifies the characteristics for the fitness for purpose of multilayer piping systems intended to be used for hot and cold water installations inside buildings for the conveyance of water — whether or not the water is intended for human consumption (domestic systems) or for heating systems — under specified design pressures and temperatures appropriate to the class of application. It also specifies the test parameters for the test methods referred to in this part of ISO 21003. ISO 21003 is a reference product standard. It is applicable to multilayer pipes, fittings, their joints, and also to joints with components made of other plastics and non-plastics materials intended to be used for hot and cold water installations. ISO 21003-5 is intended for use only in conjunction with all the other parts of ISO 21003.
Abstract
Overview
ISO 21003-5:2008 - "Multilayer piping systems for hot and cold water installations inside buildings - Part 5: Fitness for purpose of the system" - defines the characteristics and test parameters that demonstrate the fitness for purpose of multilayer pipe systems used inside buildings for hot and cold water (domestic or heating). It applies to multilayer pipes, fittings and their joints (including joints with other plastics and non‑plastics) and is intended to be used together with the other parts of ISO 21003.
Key topics and technical requirements
- Scope: Systems for conveying water inside buildings under specified design pressures and temperatures appropriate to application classes. Not applicable beyond the design temperature/pressure limits in ISO 21003-1.
- Materials: Stress-bearing polymeric layers include PB, PE-RT, PE‑X, PP and PVC‑C; PE‑X must be fully crosslinked and meet relevant product standards.
- System focus: Evaluates both joints and complete piping assemblies; tests must use the parameters in clauses 5.2–5.7.
- Mandatory tests and referenced methods:
- Internal pressure test (ISO 1167) - hydrostatic test pressures derived from pipe long‑term strength and design pressure (examples include design pressures of 4, 6, 8 or 10 bar and long-term test durations such as 1 000 h in some classes).
- Bending test (EN 713) - assesses leaktightness under bending at specified radii and pressures.
- Pull‑out test (EN 712) - verifies mechanical retention of fittings under calculated pull forces.
- Thermal cycling test (EN 12293) - checks joint resistance to temperature variations.
- Pressure cycling test (EN 12295) - evaluates joint resistance to repeated pressure changes.
- Vacuum leaktightness test (EN 12294).
- Test parameter derivation: Uses long‑term strength data, Miner’s rule (ISO 13760) and other referenced standards (e.g., ISO 17456 for long‑term strength).
Practical applications and users
- Who uses it:
- Manufacturers of multilayer pipes and fittings (product design and type testing)
- Test laboratories and conformity assessment bodies (type approval and certification)
- Specifiers, plumbing and HVAC engineers (product selection and system specification)
- Building owners, installers and contractors (compliance and installation verification)
- Practical value:
- Ensures durability, leak tightness and mechanical integrity of joints and systems under expected service conditions
- Supports product harmonization and evidence for compliance with national regulations and procurement requirements
- Facilitates selection of systems suitable for domestic potable water and heating applications
Related standards
- ISO 21003-1, -2, -3 (General, Pipes, Fittings) - use in conjunction with Part 5
- ISO/TS 21003-7 (conformity guidance)
- Product-family parallels: ISO 15875-5 (PE‑X), ISO 15874-5 (PP), ISO 15876-5 (PB), ISO 15877-5 (PVC‑C)
- Test standards: ISO 1167, EN 712, EN 713, EN 12293, EN 12294, EN 12295
Keywords: ISO 21003-5:2008, multilayer piping systems, fitness for purpose, hot and cold water installations, joint testing, internal pressure test, bending test, pull-out test, thermal cycling.
Технические детали
- Технический комитет
- ISO/TC 138/SC 2 - Plastics pipes and fittings for water supplies
- SKU
- ISO 21003-5:2008
Похожие стандарты
Стандарты, упомянутые в описании
BS EN ISO 21003-1:2008
ДействующийMultilayer piping systems for hot and cold water installations inside buildings. General.
BS EN ISO 11670:2003
ДействующийLasers and laser-related equipment. Test methods for laser beam parameters. Beam positional stability.
BS EN ISO 13760:2000
ДействующийPlastics pipes for the conveyance of fluids under pressure. Miners rule. Calculation method for cumulative da…
ISO 17456:2006
ДействующийPlastics piping systems — Multilayer pipes — Determination of long-term strength
Overview ISO 17456:2006 - Plastics piping systems - Multilayer pipes - Determination of long-term strength specifies two alternative methods to determine the long-term hydrostatic strength of multila…
ISO/TS 21003-7:2008
ОтменёнMultilayer piping systems for hot and cold water installations inside buildings — Part 7: Guidance for the as…
ISO 15875-5:2003
ОтменёнPlastics piping systems for hot and cold water installations — Crosslinked polyethylene (PE-X) — Part 5: Fitn…
Overview ISO 15875-5:2003 is the part of the ISO system standard that defines the fitness for purpose of crosslinked polyethylene (PE‑X) piping systems for hot and cold water installations inside bui…
ISO 15874-5:2013
ДействующийPlastics piping systems for hot and cold water installations — Polypropylene (PP) — Part 5: Fitness for purpo…
Overview ISO 15874-5:2013 - Plastics piping systems for hot and cold water installations - Polypropylene (PP) - Part 5: Fitness for purpose of the system defines the requirements and test parameters…