ISO 21243:2022
Radiation protection — Performance criteria for laboratories performing initial cytogenetic dose assessment of mass casualties in radiological or nuclear emergencies — General principles and application to dicentric assay
Radiation protection — Performance criteria for laboratories performing initial cytogenetic dose assessment of mass casualties in radiological or nuclear emergencies — General principles and application to dicentric assay
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 18
- Дата публикации:
- 7 ноября 2022 г.
- Издание:
- ISO IS 21243 edition 2 version 1
- ICS:
- 13.280
The purpose of this document is to give an overview of the minimum requirements for performing the dicentric assay with quality control measures using mitogen stimulated peripheral blood lymphocytes for initial assessment of individuals involved in a mass casualty scenario. The dicentric assay is the use of chromosome damage to quickly estimate approximate radiation doses received by individuals in order to supplement the early clinical categorization of casualties. This document focuses on the organizational and operational aspects of applying the dicentric assay in an initial assessment mode. The technical aspects of the dicentric assay can be found in ISO 19238. This document is applicable either to an experienced biological dosimetry laboratory working alone or to a network of collaborating laboratories (as defined in Clause 7).
Abstract
Overview
ISO 21243:2022 - Radiation protection - Performance criteria for laboratories performing initial cytogenetic dose assessment of mass casualties in radiological or nuclear emergencies - General principles and application to dicentric assay - provides minimum organizational and operational requirements for performing an expedited dicentric assay for initial dose assessment in mass-casualty radiological or nuclear events. The standard focuses on rapid, quality‑assured cytogenetic categorization of exposed individuals using mitogen-stimulated peripheral blood lymphocytes to support early clinical decision-making and triage.
Key topics and requirements
- Scope & purpose: Guidance for initial (rapid) dicentric assay use in mass-casualty incidents to estimate approximate absorbed dose and support clinical triage.
- Organizational responsibilities: Laboratory preparedness, pre‑planning, confidentiality, handling of biological dosimetry requests and reporting.
- Laboratory network design: Roles and responsibilities of lead and associate laboratories; procedures for coordinated surge capacity and network operation.
- Biological dosimetry process: Sample collection, transport integrity, simplified/expedited processing and validated scoring strategies for initial assessment.
- Quality assurance and quality control (QA/QC): Defined performance checks covering sample integrity, instrumentation, scoring, dose estimation and confidence intervals, report generation and data security.
- Performance checks: Regular verification of protocols, scoring thresholds (including manual scoring guidance), and network performance to ensure reproducible, defensible dose estimates.
- Interpretation guidance: Consideration of whole‑body vs. inhomogeneous exposures, uncertainty communication and when acute exposure assumptions may not apply (note: for low LET radiation below ~0.3 Gy linearity is generally assumed).
- Automation and validation: Semi‑ or fully automated methods may be used if validated and documented by the laboratory.
Applications and users
ISO 21243:2022 is intended for:
- National and regional biological dosimetry laboratories and cytogenetic labs involved in emergency response
- Lead laboratories coordinating multi‑laboratory networks for surge capacity
- Emergency planners, public health authorities, medical responders and hospital laboratories seeking validated procedures for rapid dose categorization
- Organizations developing training, drills and stockpiling strategies for radiological/nuclear mass-casualty preparedness
Practical uses include rapid triage support to identify non-exposed individuals, low/moderately exposed persons who need monitoring, and highly exposed patients requiring urgent treatment.
Related standards
- ISO 19238 (technical aspects of dicentric assay)
- ISO 17099 (cytokinesis-block micronucleus assay guidance)
- ISO/IEC 17025 (laboratory competence)
- ISO Guide 98 and ISO 5725 (uncertainty and accuracy guidance)
Keywords: ISO 21243:2022, dicentric assay, biological dosimetry, radiation protection, cytogenetic dose assessment, mass casualty, laboratory network, quality assurance, radiological emergency.
Технические детали
- Технический комитет
- ISO/TC 85/SC 2 - Radiological protection
- SKU
- ISO 21243:2022
Похожие стандарты
Стандарты, упомянутые в описании
BS EN ISO 19238:2023
ДействующийRadiological protection. Performance criteria for service laboratories performing biological dosimetry by cyt…
BS EN ISO 17099:2024
ДействующийRadiological protection. Performance criteria for laboratories using the cytokinesis-block micronucleus (CBMN…
BS EN ISO/IEC 17025:2017
ДействующийGeneral requirements for the competence of testing and calibration laboratories.
ISO 5725-1:2023
ДействующийAccuracy (trueness and precision) of measurement methods and results — Part 1: General principles and definit…
Overview ISO 5725-1:2023, "Accuracy (trueness and precision) of measurement methods and results - Part 1: General principles and definitions," is published by the International Organization for Stand…