ISO 22007-3:2008
Plastics — Determination of thermal conductivity and thermal diffusivity — Part 3: Temperature wave analysis method
Plastics — Determination of thermal conductivity and thermal diffusivity — Part 3: Temperature wave analysis method
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 16
- Дата публикации:
- 8 декабря 2008 г.
- Издание:
- ISO IS 22007 edition 1 version 1
- ICS:
- 83.080.01
ISO 22007-3:2008 specifies a temperature wave analysis method for the determination of the thermal diffusivity of thin films and plates of plastics in the through-thickness direction. The method can be used on plastics in either the solid or molten state, and having either an isotropic or an orthotropic structure. The method covers values of the thermal diffusivity, α, in the range 1,0 x 10-8 m2s-1 α -4 m2s-1. Measurements can be performed either in air or in another atmosphere, e.g. an inert gas, at atmospheric pressure or at other, reduced or elevated, pressures, or under a vacuum, at a variety of temperatures.
Abstract
Overview
ISO 22007-3:2008 - Plastics: Determination of thermal conductivity and thermal diffusivity - Part 3 describes the temperature wave analysis method for measuring the thermal diffusivity of thin plastic films and plates in the through-thickness direction. The standard covers solids and melts, isotropic and orthotropic plastics, and thermal-diffusivity values from 1.0 × 10⁻⁸ m²/s to 1.0 × 10⁻⁴ m²/s. Measurements may be performed in air, inert atmospheres, reduced/elevated pressures or vacuum across a range of temperatures.
Key topics and technical requirements
- Measurement principle: generate a temperature wave by a.c. Joule heating on the front surface and detect its phase shift at the rear surface; thermal diffusivity is derived from phase-shift vs. frequency analysis.
- Specimen geometry: typical thin films 10 µm–500 µm thick, usually ~10 mm × 10 mm; thickness must be measured with a calibrated micrometer or appropriate gauge before testing.
- Apparatus components: heater and sensor resistive elements (preferably sputtered on opposite faces), backing plates for liquids, specimen holder, constant-temperature enclosure, function generator, lock-in amplifier and phase-shift measurement device.
- Performance limits and controls:
- Thermal-diffusivity range: 1.0 × 10⁻⁸ to 1.0 × 10⁻⁴ m²/s.
- Temperature stability of enclosure: specimen temperature change ≤ ±1 K during measurement.
- Heater power adjusted to limit specimen temperature rise to ≤ 1 K.
- Sensor bias current: 1 µA to 10 mA.
- Recommended phase-shift accuracy: ±0.01°; frequency accuracy better than 50 ppm.
- Specimen states: suitable for solid or molten plastics and for isotropic or orthotropic materials.
- Calibration & uncertainty: standard includes provisions for calibration, verification and uncertainty analysis (see Annexes for mathematical background and uncertainty examples).
Applications and users
- Practical uses:
- R&D and material development for thin polymer films, coatings and membranes.
- Thermal characterization in electronics, packaging, nanotechnology and biomedical polymers.
- Quality control and comparative testing of thin plastic components and melts.
- Typical users:
- Materials scientists, polymer engineers, thermal analysts, test laboratories and calibration facilities needing accurate through-thickness thermal-transport data.
- Advantages: high sensitivity and good temperature resolution for small or thin specimens where conventional bulk methods are unsuitable.
Related standards
- ISO 22007-1 - General principles for thermal conductivity/diffusivity of plastics.
- ISO 22007-2 - Transient plane heat source (hot disc) method.
- ISO 22007-4 - Laser flash method.
- Normative references: ISO 472 (plastics vocabulary), ISO 80000-5 (quantities & units - thermodynamics), ISO/IEC Guide 98-3 (GUM:1995, uncertainty).
Keywords: ISO 22007-3:2008, temperature wave analysis, thermal diffusivity measurement, plastics thin films, thermal transport properties, through-thickness thermal diffusivity.
Технические детали
- Технический комитет
- ISO/TC 61/SC 5 - Physical-chemical properties
- SKU
- ISO 22007-3:2008
Похожие стандарты
Стандарты, упомянутые в описании
ISO 22007-1:2017
ОтменёнPlastics — Determination of thermal conductivity and thermal diffusivity — Part 1: General principles
ISO 22007-2:2015
ОтменёнPlastics — Determination of thermal conductivity and thermal diffusivity — Part 2: Transient plane heat sourc…
BS EN ISO 22007-4:2024
ДействующийPlastics. Determination of thermal conductivity and thermal diffusivity. Light flash method.
ISO 4725:2004
ДействующийOil of cedarwood, Texas (Juniperus mexicana Schiede)
Overview ISO 4725:2004 specifies essential quality characteristics and test requirements for Oil of cedarwood, Texas (Juniperus mexicana). The standard facilitates objective assessment of this essent…
ISO 80000-5:2007
ДействующийQuantities and units - Part 5: Thermodynamics
Overview ISO 80000-5:2007, “Quantities and units - Part 5: Thermodynamics”, defines the names, symbols and definitions for thermodynamic quantities and their units. Published as part of the ISO/IEC 8…