ISO 22197-2:2019
Fine ceramics (advanced ceramics, advanced technical ceramics) — Test method for air-purification performance of semiconducting photocatalytic materials — Part 2: Removal of acetaldehyde
Fine ceramics (advanced ceramics, advanced technical ceramics) — Test method for air-purification performance of semiconducting photocatalytic materials — Part 2: Removal of acetaldehyde
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 16
- Дата публикации:
- 15 октября 2019 г.
- Издание:
- ISO IS 22197 edition 2 version 1
- ICS:
- 81.060.30
This document specifies a test method for the determination of the air-purification performance of materials that contain a photocatalyst or have photocatalytic films, usually made from semiconducting metal oxides, such as titanium dioxide or other ceramic materials, by continuous exposure of a test piece to the model air pollutant under irradiation with ultraviolet light (UV-A). This document is intended for use with different kinds of materials, such as construction materials in flat sheet, board or plate shape, that are the basic forms of materials for various applications. This document also applies to structured filter materials including honeycomb-form, woven and non-woven fabrics, and to plastic or paper materials if they contain ceramic microcrystals and composites. This document does not apply to powder or granular photocatalytic materials. This test method is usually applicable to photocatalytic materials produced for air purification. This method is not suitable for the determination of other performance attributes of photocatalytic materials, i.e. decomposition of water contaminants, self-cleaning, antifogging and antibacterial actions. It concerns the removal of acetaldehyde.
Abstract
Overview
ISO 22197-2:2019 defines a laboratory test method for evaluating the air‑purification performance of semiconducting photocatalytic materials with respect to the removal of acetaldehyde (a representative volatile organic compound, VOC). The standard covers continuous exposure of a planar or structured test piece to a controlled acetaldehyde‑containing air stream while irradiated by near‑UV (UV‑A) light, and quantifies removal as percent removed and micromoles converted (including CO formed as an oxidation product). It is intended for performance testing of advanced ceramic (fine ceramics) photocatalytic materials and coatings commonly based on titanium dioxide and similar metal‑oxide semiconductors.
Key topics and technical requirements
- Scope and materials: Applies to flat sheets, boards, plates, honeycomb/structured filters, woven and non‑woven fabrics, and plastic or paper composites that contain ceramic microcrystals. Does not apply to powder or granular photocatalysts.
- Test principle: Flow‑type photoreactor exposes the test piece to model polluted air under UV‑A irradiation; photocatalytic oxidation and adsorption of acetaldehyde are monitored. Dark‑condition tests separate simple adsorption from photocatalytic activity.
- Apparatus: Includes test gas supply (humidifier, gas mixer, mass‑flow controllers), photoreactor with a 5.0 mm ± 0.5 mm air gap between sample and optical window, a UV‑A light source (per ISO 10677), and analytical systems for acetaldehyde and CO (referenced standards ISO 16000‑3 and ISO 4224).
- Gas and flow control: Acetaldehyde standard gas typically 50–250 µl/l before dilution; flow rates are expressed at standard state and should be controlled within ±5% (thermal mass‑flow controllers recommended).
- Measured outputs: Removal percentage of acetaldehyde, removed quantity in µmol, and conversion to CO. The method includes procedures for sample pretreatment and acceptable adsorption criteria.
- Limitations: Not suitable for evaluating photocatalytic effects on water contaminants, self‑cleaning, antifogging or antibacterial properties.
Applications and users
- Manufacturers of photocatalytic building materials, coatings and filters validating air‑purification claims.
- Independent testing and calibration laboratories seeking ISO‑compatible VOC performance data.
- Product developers and R&D teams optimizing photocatalyst formulations (e.g., TiO2‑based ceramics).
- Specifiers, architects and indoor‑air quality consultants comparing materials for VOC mitigation.
- Regulatory bodies and certification schemes requiring standardized VOC removal metrics.
Related standards
- ISO 22197 series (other pollutant test parts; e.g., ISO 22197‑1 for NO removal)
- ISO 10677 (UV light source for testing photocatalytic materials)
- ISO 16000‑3 (sampling/analysis of carbonyls)
- ISO 4224 (CO determination)
- ISO/IEC 17025 (laboratory competence)
Keywords: ISO 22197‑2, photocatalytic materials, acetaldehyde removal, air purification, fine ceramics, titanium dioxide, UV‑A photoreactor, VOC removal, indoor air quality.
Технические детали
- Технический комитет
- ISO/TC 206 - Fine ceramics
- SKU
- ISO 22197-2:2019
Похожие стандарты
Стандарты, упомянутые в описании
BS ISO 10677:2011
ДействующийFine ceramics (advanced ceramics, advanced technical ceramics). Ultraviolet light source for testing semicond…
ISO 16000-3:2022
ДействующийIndoor air — Part 3: Determination of formaldehyde and other carbonyl compounds in indoor and test chamber ai…
Overview ISO 16000-3:2022 specifies an active sampling method for measuring formaldehyde and other carbonyl compounds in indoor and test-chamber air. The standard defines collection on silica gel car…
ISO 4224:2000
ДействующийAmbient air — Determination of carbon monoxide — Non-dispersive infrared spectrometric method
Overview - ISO 4224:2000 (Ambient air - Carbon monoxide, NDIR method) ISO 4224:2000 specifies a non-dispersive infrared (NDIR) spectrometric method for the continuous analysis and recording of carbon…