ISO 23640:2011
In vitro diagnostic medical devices — Evaluation of stability of in vitro diagnostic reagents
In vitro diagnostic medical devices — Evaluation of stability of in vitro diagnostic reagents
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 7
- Дата публикации:
- 29 ноября 2011 г.
- Издание:
- ISO IS 23640 edition 1 version 1
- ICS:
- 11.100.10
ISO 23640:2011 is applicable to the stability evaluation of in vitro diagnostic medical devices, including reagents, calibrators, control materials, diluents, buffers and reagent kits, hereinafter called IVD reagents. ISO 23640:2011 can also be applied to specimen collection devices that contain substances used to preserve samples or to initiate reactions for further processing of the sample in the collection device. ISO 23640:2011 specifies general requirements for stability evaluation and gives specific requirements for real time and accelerated stability evaluation when generating data in: the establishment of IVD reagent shelf life, including transport conditions suitable to ensure that product specifications are maintained; the establishment of stability of the IVD reagent in use after the first opening of the primary container; the monitoring of stability of IVD reagents already placed on the market; the verification of stability specifications after modifications of the IVD reagent that might affect stability.
Abstract
Overview
ISO 23640:2011 - "In vitro diagnostic medical devices - Evaluation of stability of in vitro diagnostic reagents" - defines requirements for designing, performing and reporting stability evaluations of in vitro diagnostic (IVD) reagents. It applies to reagents, calibrators, control materials, diluents, buffers, reagent kits and specimen collection devices that contain stabilizing or reactive substances. The standard supports establishing shelf life, transport and in‑use stability (e.g., open-vial or reconstituted stability), post‑market monitoring, and verification after product changes.
Key topics and technical requirements
- Stability evaluation scope: Real‑time and accelerated stability studies to justify expiry dates, transport conditions, and in‑use claims.
- Protocol requirements: Pre‑established protocol must document responsibilities, clear reagent identification, use conditions, objectives, sample information (batch/lot), critical components, storage and transport simulations, sampling intervals, examinations, data analysis methods, acceptance criteria and interpretation.
- Study design: Minimum batch numbers defined by objective - typically 3 batches for new shelf‑life or extensions (real‑time), and 1 batch for transport simulation, in‑use stability or certain post‑modification checks (risk‑based exceptions allowed).
- Accelerated studies: Acceptable for initial expiry dating where appropriate; analysis may use Arrhenius plots or non‑linear modelling. Accelerated data must be confirmed by real‑time studies when used for market introduction.
- Data and reporting: Stability reports must reference the protocol, batches tested, all results, data analysis, pass/fail against acceptance criteria and final conclusions.
- Risk management: Link to ISO 14971 for assessing when fewer batches or altered conditions are justified; manufacturers must assess risks from labile components and production differences.
- Post‑market: Requirement to establish stability monitoring where necessary and to reassess stability after manufacturing or product modifications.
Applications
- Establishing and documenting shelf life and expiry dates for IVD reagents and kits.
- Defining transport conditions (temperature, humidity, vibration) that preserve reagent performance.
- Demonstrating in‑use stability (on‑board, reconstituted, open vial) for clinical laboratories and point‑of‑care devices.
- Supporting regulatory submissions, technical documentation and quality systems by providing validated stability data.
- Guiding stability monitoring and verification after product changes or during post‑market surveillance.
Who should use this standard
- IVD manufacturers (R&D, quality assurance, regulatory affairs)
- Stability study designers and laboratory scientists
- Clinical laboratories assessing reagent claims
- Regulatory bodies reviewing IVD technical documentation
Related standards
- ISO 14971 (risk management for medical devices)
- CLSI EP25‑A (guidance on stability evaluation methods)
- EN 13640 (basis for ISO 23640)
Keywords: ISO 23640, in vitro diagnostic reagents, stability evaluation, shelf life, accelerated stability, real‑time stability, transport stability, in‑use stability, stability protocol.
Технические детали
- Технический комитет
- ISO/TC 212 - Clinical laboratory testing and in vitro diagnostic test systems
- SKU
- ISO 23640:2011
Похожие стандарты
Упомянутые в описании и другие стандарты ISO
ISO 14971:2007
ДействующийMedical devices - Application of risk management to medical devices
Overview ISO 14971:2007 - Medical devices - Application of risk management to medical devices - defines a systematic process for identifying hazards, estimating and evaluating risks, implementing ris…
BS EN ISO 23640:2015
ДействующийIn vitro diagnostic medical devices. Evaluation of stability of in vitro diagnostic reagents.
ISO 8212:1986
ОтменёнSoaps and detergents — Techniques of sampling during manufacture
Overview Standard Reference: ISO 8212:1986 Title: Soaps and detergents - Techniques of sampling during manufacture ISO 8212:1986 defines standardized techniques for taking representative samples of s…
ISO 20662:2020
ДействующийShips and marine technology — Hopper dredger supervisory and control systems
Overview ISO 20662:2020 - Ships and marine technology: Hopper dredger supervisory and control systems (HD‑SCS) - specifies the components, structure, general requirements, and functional requirements…
ISO 3021:2023
ДействующийAdventure tourism — Hiking and trekking activities — Requirements and recommendations
Overview ISO 3021:2023 - Adventure tourism: Hiking and trekking activities - Requirements and recommendations defines safety-focused requirements and recommendations for hiking and trekking offered a…
ISO 3826-2:2008
ДействующийPlastics collapsible containers for human blood and blood components — Part 2: Graphical symbols for use on l…
Overview ISO 3826-2:2008 - "Plastics collapsible containers for human blood and blood components - Part 2: Graphical symbols for use on labels and instruction leaflets" defines a system of internatio…
ISO/IEC 24730-1:2014
ДействующийInformation technology — Real-time locating systems (RTLS) — Part 1: Application programming interface (API)
Overview ISO/IEC 24730-1:2014 specifies the Application Programming Interface (API) for Real‑Time Locating Systems (RTLS). The standard defines a minimal, interoperable boundary that lets application…
ISO 8668-5:1992
ДействующийAircraft — Terminal junction systems — Part 5: Detail specification for type 3 system
Overview - ISO 8668-5:1992 (Aircraft terminal junction systems, Type 3) ISO 8668-5:1992 defines the detail specification for Type 3 Terminal Junction Systems (TJS) used in aircraft electrical install…