ISO 27895:2009 specifies methods for the leak testing of vacuum valves used for control of gas flow or vacuum pressure in a vacuum system.It is applicable to vacuum valves that can be closed to leak rates less than 1 x 10-5 Pa m3/s for trace gas. The methods employ a sealing arrangement for the valve body, which is also specified in ISO 27895:2009. The methods are suitable for the verification of valve specifications. A valve leak rate less than the nominal leak rate specified by the manufacturer during and after the operation enables the specification of such valve operating conditions as operating pressure range, permissible pressure difference between ports, bake-out temperature or operating temperature, and life cycle.
Abstract
Overview
ISO 27895:2009 - Vacuum technology - Valves - Leak test - defines standardized methods to leak-test vacuum valves used to control gas flow or vacuum pressure. It applies to valves that can be closed to leak rates below 1 × 10‑5 Pa·m3/s (trace gas) and specifies a sealing arrangement and test configurations for verification of valve specifications. The standard supports reproducible measurement of valve leak rates during and after operation so manufacturers and users can define operating pressure ranges, permissible pressure differences, bake-out/operating temperatures, and lifecycle expectations.
Key topics and technical requirements
- Test scope: Valve seat leak test and valve body leak test are the primary methods; optional tests cover pneumatic pressure extremes, manual torque extremes, operating temperature range and post‑bake testing.
- Leak types: Distinguishes real leaks, virtual leaks (outgassing/trapped volumes) and permeation leaks (through materials). Virtual leaks are not measurable by the methods in ISO 27895.
- Trace gas & detectors: Mass‑spectrometer‑type leak detectors (typically helium) are used. Detectors must be calibrated to a standard leak (see ISO 3530) and have detection limits better than the valve’s nominal leak rate.
- Test configurations: Multiple port‑connection configurations (four main setups) for seat testing; a hood filled with trace gas at ~100 kPa for body testing. A probe method is available for qualitative/comparative measurements.
- Environmental & procedural controls:
- Ambient temperature: (23 ± 7) °C.
- Sealing surfaces must be clean and dry.
- Detector warm‑up, tuning and calibration required; waiting times for measurement must minimize permeation effects (typically <30 s where practical).
- Helium mixtures should have a controlled helium fraction (>10% recommended) and measured values corrected for volume fraction where necessary.
Practical applications and users
- Who uses ISO 27895:
- Vacuum valve manufacturers (type testing, delivery inspection, specification verification)
- Independent test laboratories and quality assurance teams
- Vacuum system designers and integrators in industries such as semiconductor manufacturing, research labs, vacuum coating, particle accelerators and analytical instrumentation
- Procurement and maintenance engineers specifying acceptance criteria and in‑service verification
- Why it matters: Standardized leak testing enables consistent valve selection, reliable system performance, correct specification of operating limits (pressure, temperature, differential), and predictable valve lifetime behavior.
Related standards
Технические детали
- Технический комитет
- ISO/TC 112 - Vacuum technology
- SKU
- ISO 27895:2009
Похожие стандарты
Упомянутые в описании и другие стандарты ISO
BS ISO 27895:2009
ДействующийVacuum technology. Valves. Leak test.
ISO 3530:1979
ДействующийVacuum technology — Mass-spectrometer-type leak-detector calibration
Overview ISO 3530:1979 - Vacuum technology - Mass-spectrometer-type leak-detector calibration - defines standardized procedures for calibrating mass‑spectrometer (MS) type leak detectors that include…
ISO 8212:1986
ОтменёнSoaps and detergents — Techniques of sampling during manufacture
Overview Standard Reference: ISO 8212:1986 Title: Soaps and detergents - Techniques of sampling during manufacture ISO 8212:1986 defines standardized techniques for taking representative samples of s…
ISO 20662:2020
ДействующийShips and marine technology — Hopper dredger supervisory and control systems
Overview ISO 20662:2020 - Ships and marine technology: Hopper dredger supervisory and control systems (HD‑SCS) - specifies the components, structure, general requirements, and functional requirements…
ISO 3021:2023
ДействующийAdventure tourism — Hiking and trekking activities — Requirements and recommendations
Overview ISO 3021:2023 - Adventure tourism: Hiking and trekking activities - Requirements and recommendations defines safety-focused requirements and recommendations for hiking and trekking offered a…
ISO 3826-2:2008
ДействующийPlastics collapsible containers for human blood and blood components — Part 2: Graphical symbols for use on l…
Overview ISO 3826-2:2008 - "Plastics collapsible containers for human blood and blood components - Part 2: Graphical symbols for use on labels and instruction leaflets" defines a system of internatio…
ISO/IEC 24730-1:2014
ДействующийInformation technology — Real-time locating systems (RTLS) — Part 1: Application programming interface (API)
Overview ISO/IEC 24730-1:2014 specifies the Application Programming Interface (API) for Real‑Time Locating Systems (RTLS). The standard defines a minimal, interoperable boundary that lets application…
ISO 8668-5:1992
ДействующийAircraft — Terminal junction systems — Part 5: Detail specification for type 3 system
Overview - ISO 8668-5:1992 (Aircraft terminal junction systems, Type 3) ISO 8668-5:1992 defines the detail specification for Type 3 Terminal Junction Systems (TJS) used in aircraft electrical install…