ISO 28523:2009
Ships and marine technology — Lubricating and hydraulic oil systems — Guidance for sampling to determine cleanliness and particle contamination
Ships and marine technology — Lubricating and hydraulic oil systems — Guidance for sampling to determine cleanliness and particle contamination
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 7
- Дата публикации:
- 9 февраля 2009 г.
- Издание:
- ISO IS 28523 edition 1 version 1
- ICS:
- 47.020.99
ISO 28523:2009 specifies methods for dynamic and static extraction of fluid samples from lubricating and hydraulic oil systems. A correct execution of the sampling is essential when analysing fluids from lubricating and hydraulic oil systems. In order to achieve reliable and comparable analysis results, the sampling must be performed under defined conditions and operating environment. When the system has reached its operating temperature, a representative sample is extracted from where the fluid is in a turbulent flow condition. This method is called dynamic sampling. If this is not possible, the sample can be extracted from the system tank. This method is called static sampling. ISO 28523:2009 specifies methods for both dynamic and static sampling in connection with collection in bottles. For extraction of samples through a filtration kit for comparison with “master slides”, reference is made to the manuals from the suppliers of such equipment.
Abstract
Overview
ISO 28523:2009 - Ships and marine technology - Guidance for sampling to determine cleanliness and particle contamination - provides practical methods to extract representative fluid samples from lubricating and hydraulic oil systems on ships and marine machinery. The standard explains how to perform dynamic and static sampling, how to collect samples in compliant bottles, and how to prepare samples for particle counting or microscopic cleanliness evaluation to obtain reliable, comparable contamination data.
Key topics and requirements
- Representative sampling
- Samples must be taken when the system has reached operating temperature and, where possible, from a location with turbulent flow (dynamic sampling) to avoid particle settling.
- If dynamic sampling is not feasible, static sampling from the system tank is permitted (note: particles > 20 µm settle quickly during static sampling).
- Dynamic sampling rigging
- Use a sampling device with a flexible capillary; internal diameter should comply with ISO 4021 (minimum 1.25 mm where applicable).
- Ensure at least 0.5 L of fluid passes through the sampling line before collecting the actual sample. For automatic particle counters, extract at least 0.4 L.
- Fill sample bottle to 50–80% of its volume, remove the bottle while fluid still flows, and close immediately. Do not immerse the capillary tube into the bottle to avoid contamination.
- Static sampling methods
- Procedures mirror dynamic sampling steps for filling and handling; vacuum-assisted extraction is an accepted option.
- Sample bottles and labeling
- Bottles must meet ISO 3722 cleanliness requirements, be sealed when delivered, be chemically compatible and transparent, and carry clear identification (date, plant, sample location, pressure, running hours).
- Automatic particle counting
- Pre‑checks and preparation include water content measurement (Karl Fischer); automatic counting is allowed only if water < 0.05% mass fraction.
- Typical preparation: heat to ~65 °C, shake 5 minutes, ultrasonic 15 s, degas under vacuum (50–80 kPa), then perform counting and convert results to ISO-contamination code (ISO 4406).
- Microscopy
- Used for flushing evaluation and qualitative assessment; follow membrane filtration guidance (e.g., 1.2 µm filters), heat to ~40 °C and shake before filtration, and use a consistent operator for repeatability.
Applications and users
- Target users: ship engineers, marine maintenance teams, oil analysis laboratories, equipment OEMs, classification societies, and technical managers responsible for reliability and contamination control.
- Practical uses:
- Condition-based maintenance and contamination monitoring of main engines, gears, steering gear, and hydraulic systems.
- Acceptance testing after newbuilds, repairs, filtration upgrades, or flushing procedures.
- Providing consistent sample protocols for trend analysis, warranty claims, and contamination-control programs.
Related standards
- ISO 3722 - Fluid sample containers - cleaning/qualification
- ISO 4021 - Extraction of fluid samples from lines of an operating system
- ISO 4406 - Coding of contamination by solid particles
- ISO 11171, ISO 28521 - Referenced for particle counter calibration and guidance on cleanliness grades
Keywords: ISO 28523:2009, sampling, lubricating and hydraulic oil systems, dynamic sampling, static sampling, particle contamination, oil cleanliness, marine maintenance.
Технические детали
- Технический комитет
- ISO/TC 8/SC 3 - Piping and machinery
- SKU
- ISO 28523:2009
Похожие стандарты
Стандарты, упомянутые в описании
ISO 4021:1992
ДействующийHydraulic fluid power — Particulate contamination analysis — Extraction of fluid samples from lines of an ope…
Overview ISO 4021:1992 is an international standard developed by the International Organization for Standardization (ISO) that specifies the preferred methods for extracting fluid samples from hydrau…
ISO 3722:1976
ДействующийHydraulic fluid power — Fluid sample containers — Qualifying and controlling cleaning methods
Overview ISO 3722:1976, titled "Hydraulic fluid power - Fluid sample containers - Qualifying and controlling cleaning methods," is an international standard developed by the International Organizatio…
BS ISO 4406:2021
ДействующийHydraulic fluid power. Fluids. Method for coding the level of contamination by solid particles.
ISO/TR 6057:2023
ДействующийHydraulic fluid power — Sample calculations for ISO 11171
Overview ISO/TR 6057:2023 – "Hydraulic fluid power - Sample calculations for ISO 11171" is an ISO technical report that provides worked examples showing how to apply the normative mathematical formul…