ISO 28620:2020
Medical devices — Non-electrically driven portable infusion devices
Medical devices — Non-electrically driven portable infusion devices
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 12
- Дата публикации:
- 16 января 2020 г.
- Издание:
- ISO IS 28620 edition 2 version 1
- ICS:
- 11.040.20
This document specifies essential requirements and related test methods for non-electrically driven portable infusion devices, thereafter called "device". It is applicable to devices designed for continuous (fixed or adjustable) flow and/or for bolus neuraxial and intravascular or hypodermic applications. NOTE Sites for the neuraxial application include the spine, intrathecal or subarachnoid space, ventricles of the brain and the epi-, extra- or peri-dural space. Neuraxial application anaesthetics can be administered regionally, affecting a large part of the body, such as a limb, and include plexus blocks, such as the branchial plexus blocks or single nerve blocks. Neuraxial application procedures include continuous infusion of wounds with local anaesthetic agents. These devices can be used in health care and non-health care settings. They can be applied or administered by health care professionals or by the intended patient. These devices can be pre-filled by the manufacturer or filled before use by a health care professional or the intended patient. This document does not apply to — electrically driven or electrically controlled infusion pumps that are covered by IEC 60601-2-24, — devices for single patient use intended to deliver discrete volumes (bolus) of medicinal product that are covered by the ISO 11608 series, — implantable devices, — enteral devices, — transdermal delivery devices, and — devices where the energy for infusion is not provided by the device or through active intervention by the patient (e.g. devices only powered by gravity).
Abstract
Overview
ISO 28620:2020 - Medical devices - Non-electrically driven portable infusion devices - specifies essential requirements and test methods for portable infusion devices that do not use electrical power. It covers devices intended for continuous (fixed or adjustable) flow and/or bolus delivery for neuraxial and intravascular/hypodermic applications. The standard applies to devices used in healthcare and non‑healthcare settings, whether filled by the manufacturer, a clinician or the patient.
Key topics and requirements
- Scope exclusions: does not apply to electrically driven pumps (IEC 60601‑2‑24), implantable devices, enteral or transdermal delivery systems, single‑bolus devices covered by ISO 11608, or gravity‑only systems.
- Core components: must include a means to convert non‑electric energy to fluid flow, a flow restrictor, a reservoir and a particulate filter. Additional features may include adjustable flow systems, filling ports, lock connectors, clamps, bolus systems, tubing and air‑elimination features.
- Materials and biocompatibility: materials in contact with drug solutions require biological evaluation in accordance with ISO 10993‑1.
- Connectors and fittings: fittings must conform to ISO 80369‑1, and where applicable ISO 80369‑6 (neuraxial) and ISO 80369‑7 (intravascular/hypodermic).
- Filter performance: particulate filter retention when tested per the standard shall be not less than 80% for latex particles.
- Design and performance: device design must meet declared nominal flow rate, mean and instantaneous flow characteristics, bolus volume and refill time requirements.
- Testing methods: includes procedures for determination of flow rate, resistance to pressure, drop testing, water‑tightness, resistance to traction, bolus volume, refill time and fluid filter efficiency.
- Labelling and documentation: requirements for marking, nominal volumes, nominal bolus/refill times, packaging information and accompanying instructions for use.
Applications and users
ISO 28620:2020 is used by:
- Medical device manufacturers designing and validating non‑electrically driven infusion devices (wearable or portable infusion systems).
- Design and quality engineers for establishing performance and testing protocols.
- Regulatory and compliance teams preparing technical documentation for market approval.
- Test laboratories conducting conformity and performance testing per specified methods.
- Healthcare procurement and clinical staff evaluating device suitability for neuraxial or intravascular therapy in hospital, outpatient or home care settings.
Related standards
- ISO 10993‑1 - Biological evaluation of medical devices
- ISO 80369‑1, ‑6, ‑7 - Small‑bore connectors for healthcare applications
- IEC 60601‑2‑24 and ISO 11608 series (not covered by ISO 28620; referenced for excluded device types)
Keywords: ISO 28620:2020, non‑electrically driven portable infusion devices, infusion device standards, neuraxial infusion, intravascular infusion, flow rate testing, filter efficiency, ISO 80369, ISO 10993‑1.
Технические детали
- Технический комитет
- ISO/TC 76 - Transfusion, infusion and injection, and blood processing equipment for medical and pharmaceutical use
- SKU
- ISO 28620:2020
Похожие стандарты
Стандарты, упомянутые в описании
IEC 60601-2-24:2012
ДействующийMedical electrical equipment - Part 2-24: Particular requirements for the basic safety and essential performa…
Overview IEC 60601-2-24:2012 is an international standard issued by the International Electrotechnical Commission (IEC) that specifies the basic safety and essential performance requirements for medi…
ISO 11608-7:2016
ДействующийNeedle-based injection systems for medical use — Requirements and test methods — Part 7: Accessibility for pe…
Overview ISO 11608-7:2016 - "Needle-based injection systems for medical use - Part 7: Accessibility for persons with visual impairment" - specifies requirements and test methods to make needle-based…
ISO 10993-12:2012
ОтменёнBiological evaluation of medical devices — Part 12: Sample preparation and reference materials
SIST EN ISO 80369-1:2026
ДействующийSmall-bore connectors for liquids and gases in healthcare applications - Part 1: General requirements (ISO 80…
Overview SIST EN ISO 80369-1:2026 sets out the general requirements for small-bore connectors used in healthcare applications involving the conveyance of liquids and gases. This standard, aligned wit…
ISO 80369-6:2016
ДействующийSmall bore connectors for liquids and gases in healthcare applications - Part 6: Connectors for neuraxial app…
Overview ISO 80369-6:2016 defines requirements for small-bore connectors for neuraxial applications - connectors used to deliver liquids and gases to neuraxial sites (spine, intrathecal/subarachnoid…
ISO 80369-7:2016
ДействующийSmall-bore connectors for liquids and gases in healthcare applications -- Part 7: Connectors for intravascula…
Overview ISO 80369-7:2016 specifies the design, dimensional and performance requirements for small-bore connectors used in intravascular and hypodermic applications - commonly known as luer connector…
ISO 28620:2010
ОтменёнMedical devices — Non-electrically driven portable infusion devices
ISO 80369-20:2015
ДействующийSmall-bore connectors for liquids and gases in healthcare applications -- Part 20: Common test methods
Overview - ISO 80369-20:2015 (Common test methods for small-bore connectors) ISO 80369-20:2015 defines the common test methods used to evaluate the performance requirements of small-bore connectors f…