ISO 2871-2:2010 specifies a method for the determination of low-molecular-mass cationic-active materials such as monoamines, amine oxides, quaternary ammonium compounds and alkyl-pyridinium salts which have a main chain of 10 to 22 carbon atoms and not more than 6 other carbon atoms in the cation. The method is also suitable for other cationic-active materials. The method is applicable to solids or to aqueous solutions of the active material. The method is not applicable if anionic and/or amphoteric surface active agents are present.
Abstract
Overview
ISO 2871-2:2010 specifies an analytical titration method for determining the content of low‑molecular‑mass cationic-active matter (molar mass between 200 and 500) in detergents and surfactant products. The standard covers monoamines, amine oxides, quaternary ammonium compounds and alkyl‑pyridinium salts that have a main hydrocarbon chain of 10–22 carbon atoms (and no more than six other carbon atoms in the cation). The method applies to solid materials or aqueous solutions when the relative molecular mass is known or estimated, and it is not applicable where anionic and/or amphoteric surfactants are present.
Key topics and requirements
- Principle: biphasic (water–chloroform) titration using an anionic standard (sodium laurylsulfate) and a mixed dye indicator (acid blue 1 with dimidium bromide). Cationic surfactants form colored ion pairs that migrate to the chloroform layer; end point is a color change from blue to pale grey‑pink.
- Reagents & concentrations: typical reagents include chloroform (ρ ≈ 1.48 g·ml−1, specified distillation range) and a sodium laurylsulfate titrant (prepared and purity‑checked; example concentration ~0.004 mol·L−1).
- Indicator system: preparation of a mixed indicator (acid blue 1 and dimidium bromide), with an acidic indicator solution for use in the biphasic titration.
- Sampling and sample size: laboratory sample preparation per ISO 607; sample mass selected to contain about 0.002–0.003 mol of cationic active matter (guidance table uses an example M = 360).
- Procedure parameters: common procedural volumes from the standard - 25 ml aliquot, 10 ml indicator solution, 15 ml chloroform - and titration to disappearance of the blue color in the chloroform phase.
- Calculations & reporting: formula to convert titrant volume to mass % cationic-active matter (requires titrant concentration and molecular mass of the active). Precision statements: repeatability ~1.6% and reproducibility ~4% (relative to mean).
- Limitations: method is unsuitable in presence of interfering anionic or amphoteric surfactants; some hydrotropes and non‑ionic components may not interfere under specified limits.
Applications and users
- Quality control and batch release testing in detergent and surfactant manufacturing
- Raw‑material verification and incoming goods inspection for cationic surfactants
- Analytical and contract laboratories performing surfactant content assays
- R&D and formulation teams assessing cationic active content in rinse aids, fabric softeners, antimicrobial agents and similar products
- Regulators and standards bodies referencing a validated method for product compliance
Related standards
- ISO 2871‑1 (cationic-active matter of high molecular mass)
- ISO 607 (sampling of detergents)
- ISO 3696 (laboratory water quality)
- ISO 385, ISO 1042 (volumetric glassware specifications)
- ISO 2271 (anionic-active matter determination)
Keywords: ISO 2871-2:2010, cationic-active matter, detergents, surfactants, titration, sodium lauryl sulfate, low molecular mass, analytical method, quality control.
Технические детали
- Технический комитет
- ISO/TC 91 - Surface active agents
- SKU
- ISO 2871-2:2010
Похожие стандарты
Стандарты, упомянутые в описании
ISO 6078:1982
ДействующийBlack tea — Vocabulary
Overview ISO 6078:1982 - Black tea - Vocabulary is an international standard published by ISO (first edition 1982) that provides a bilingual (English/French) glossary of terms used in the commercial…
BS EN ISO 2871-1:2010
ДействующийSurface active agents. Detergents. Determination of cationic-active matter content. High-molecular-mass catio…
BS EN ISO 3696:1995
ДействующийWater for analytical laboratory use. Specification and test methods.
ISO 3856-1:1984
ДействующийPaints and varnishes — Determination of "soluble" metal content — Part 1: Determination of lead content — Fla…
Overview ISO 3856-1:1984 is an international standard published by the International Organization for Standardization (ISO) that specifies methods for determining the "soluble" lead content in paints…
ISO 10426-2:2003
ДействующийPetroleum and natural gas industries — Cements and materials for well cementing — Part 2: Testing of well cem…
Overview ISO 10426-2:2003 - "Petroleum and natural gas industries - Cements and materials for well cementing - Part 2: Testing of well cements" specifies requirements and recommendations for laborato…
ISO 22718:2015
ДействующийCosmetics — Microbiology — Detection of Staphylococcus aureus
Overview ISO 22718:2015 - Cosmetics - Microbiology - Detection of Staphylococcus aureus provides standardized guidance for detecting and identifying Staphylococcus aureus in cosmetic products. The st…