ISO 2962:2010
Cheese and processed cheese products — Determination of total phosphorus content — Molecular absorption spectrometric method
Cheese and processed cheese products — Determination of total phosphorus content — Molecular absorption spectrometric method
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 6
- Дата публикации:
- 21 мая 2010 г.
- Издание:
- ISO IS 2962 edition 3 version 1
- ICS:
- 67.100.30
ISO 2962|IDF 33:2010 specifies a molecular absorption spectrometric method for the determination of the total phosphorus content of cheese. The method is applicable to all kinds of cheese and to processed cheese products.
Abstract
Overview
ISO 2962:2010 - "Cheese and processed cheese products - Determination of total phosphorus content - Molecular absorption spectrometric method" specifies a validated spectrometric procedure for measuring total phosphorus in all types of cheese and processed cheese. The method uses wet mineralization followed by formation of a molybdenum blue complex and molecular absorption measurement at 820 nm. Results are reported as a percentage of total phosphorus (expressed to two decimals).
Key topics and technical requirements
- Scope: Applicable to all kinds of cheese and processed cheese products.
- Principle: Wet digestion (concentrated sulfuric acid + hydrogen peroxide) to mineralize the sample, reaction with sodium molybdate/ascorbic acid to produce a blue molybdenum complex, and absorbance measurement at 820 nm by a spectrometer.
- Sample preparation: Remove rind, homogenize (grind or grate) and take a representative test portion (typically 0.5–1.0 g depending on moisture content).
- Reagents: Analytical-grade sulfuric acid, ~30% hydrogen peroxide, sodium molybdate solution, freshly prepared ascorbic acid reagent, and a phosphate standard (prepared from dried potassium dihydrogen phosphate).
- Apparatus: Clean phosphorus‑free glassware, Kjeldahl or attack flasks (≈25 mL), 10 mm pathlength cuvettes, spectrometer capable of 820 nm, water baths for digestion and color development.
- Procedure highlights: Digest until colorless, dilute to volume, aliquot and add molybdate–ascorbic reagent, heat in a boiling water bath ~15 minutes, cool and measure absorbance within 1 hour.
- Calibration & blank: Use a multi‑point calibration curve from phosphate standards (e.g., 0–50 µg P equivalents) and run a procedural blank.
- Calculation & reporting: Convert measured phosphorus (from the calibration) to % total phosphorus in the original sample; report results with two decimals.
- Performance: Stated repeatability and reproducibility limits (precision figures provided in the standard).
Applications and who uses it
- Dairy quality-control laboratories: routine monitoring of nutrient labeling and formulation control.
- Food manufacturers & process development teams: recipe development and verification for cheeses and processed cheese products.
- Regulatory & inspection bodies: compliance testing for nutrition labeling and food safety audits.
- Research laboratories: compositional studies, mineral nutrition research, and method validation.
Keywords: ISO 2962:2010, total phosphorus, cheese analysis, molecular absorption spectrometric method, molybdenum blue, spectrophotometry, phosphorus determination, sample digestion, dairy laboratories.
Related standards
- ISO 707 | FIL 50 - Sampling guidelines for milk and dairy products
- ISO 648, ISO 835, ISO 1042, ISO 4788 - laboratory glassware and pipette standards referenced for apparatus and measuring devices
For implementation, consult the full ISO 2962:2010 document for complete reagent recipes, exact volumes, safety notes and the formal calculation/precision data.
Технические детали
- Технический комитет
- ISO/TC 34/SC 5 - Milk and milk products
- SKU
- ISO 2962:2010
Похожие стандарты
Стандарты, упомянутые в описании
ISO 707:2008
ДействующийMilk and milk products — Guidance on sampling
Overview ISO 707:2008 (IDF 50:2008) - "Milk and milk products - Guidance on sampling" provides practical guidance for sampling milk and milk products intended for microbiological, chemical, physical…
ISO 6481:2019
ДействующийTest conditions for vertical surface type broaching machines — Testing of accuracy
Overview ISO 6481:2019 - Test conditions for vertical surface type broaching machines - Testing of accuracy - specifies geometric accuracy tests and tolerances for vertical surface type broaching mac…
ISO 835-3:1981
ОтменёнLaboratory glassware — Graduated pipettes — Part 3: Pipettes for which a waiting time of 15 s is specified
ISO 10426-2:2003
ДействующийPetroleum and natural gas industries — Cements and materials for well cementing — Part 2: Testing of well cem…
Overview ISO 10426-2:2003 - "Petroleum and natural gas industries - Cements and materials for well cementing - Part 2: Testing of well cements" specifies requirements and recommendations for laborato…
ISO 4788:2005
ДействующийLaboratory glassware — Graduated measuring cylinders
Overview ISO 4788:2005 is an international standard specifying the dimensions, materials, and metrological requirements for laboratory glassware-specifically graduated measuring cylinders. It covers…