ISO 29661:2012
Reference radiation fields for radiation protection — Definitions and fundamental concepts
Reference radiation fields for radiation protection — Definitions and fundamental concepts
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 35
- Дата публикации:
- 30 августа 2012 г.
- Издание:
- ISO IS 29661 edition 1 version 1
- ICS:
- 13.280
ISO 29661:2012 defines terms and fundamental concepts for the calibration of dosemeters and equipment used for the radiation protection dosimetry of external radiation -- in particular, for beta, neutron and photon radiation. It defines the measurement quantities for radiation protection dosemeters and doserate meters and gives recommendations for establishing these quantities. For individual monitoring, it covers whole body and extremity dosemeters (including those for the skin and the eye lens), and for area monitoring, portable and installed dosemeters. Guidelines are given for the calibration of dosemeters and doserate meters used for individual and area monitoring in reference radiation fields. Recommendations are made for the position of the reference point and the phantom to be used for personal dosemeters. ISO 29661:2012 also deals with the determination of the response as a function of radiation quality and angle of radiation incidence. ISO 29661:2012 is intended to be used by calibration laboratories and manufacturers.
Abstract
Overview
ISO 29661:2012 - Reference radiation fields for radiation protection: Definitions and fundamental concepts provides a harmonized vocabulary and the fundamental metrology concepts used when calibrating dosemeters and doserate meters for external radiation protection. The standard addresses calibration and characterization for beta, neutron and photon reference radiation fields, defines the measurement and operational quantities used for individual monitoring (whole‑body, extremity, skin, eye lens) and area monitoring (portable and installed survey meters), and gives recommendations for reference conditions used by calibration laboratories and manufacturers.
Keywords: ISO 29661:2012, reference radiation fields, radiation protection, calibration, dosemeters, doserate meters.
Key technical topics and requirements
- Terms and definitions: Unified terminology for calibration metrology (e.g., calibration coefficient N(U,α), calibration factor C(U,α), instrument constant, corrected indication Gcorr, influence quantities).
- Measurement and operational quantities: Specifies ambient and directional dose equivalents (H*(10), H'(0.07, Ω), H'(3, Ω)) for area monitoring and personal dose equivalents (Hp(10), Hp(0.07), Hp(3)) for individual monitoring, and the recommended procedures for deriving them from primary quantities (air kerma, fluence, absorbed dose).
- Calibration principles: Guidance on establishing calibration coefficients and factors in reference radiation fields, normalization to reference conditions, and documentation of calibration conditions.
- Reference point and phantom recommendations: Positions for the reference point on personal dosemeters and the use of phantoms when calibrating personal dosimetry.
- Response characterization: Methods to determine dosemeter response as a function of radiation quality (energy) and angle of incidence.
- Uncertainty and certification: Requirements for evaluating measurement uncertainty (GUM/ISO Guide 98-3) and for calibration certificates (traceability and reporting).
- Normative annexes: Lists of reference and standard test conditions, and descriptive requirements for calibration coefficients.
Keywords: calibration coefficient, operational quantities, measurement uncertainty, reference conditions.
Practical applications and users
- Calibration laboratories performing traceable calibrations of personal and area dosemeters.
- Manufacturers designing and testing radiation protection dosemeters and survey meters.
- Dosimetry service providers and health‑physics teams validating device performance across energies and angles.
- Regulators and accreditation bodies referencing standardized definitions and reporting formats.
ISO 29661:2012 supports consistent, comparable dosimetry results used in occupational exposure control, environmental monitoring, and radiation safety programs.
Related standards
- ISO 4037 (photon reference radiation fields)
- ISO 6980 (beta reference radiation fields)
- ISO 8529 (neutron reference radiation fields)
- ISO 12789 (dosimetry topics)
- ICRU reports and ISO/IEC 17025; ISO/IEC Guide 98‑3 (GUM) for uncertainty evaluation
Using ISO 29661:2012 alongside these standards helps ensure harmonized calibration practice and clear communication of dosimetry measurement results.
Технические детали
- Технический комитет
- ISO/TC 85/SC 2 - Radiological protection
- SKU
- ISO 29661:2012
Похожие стандарты
Стандарты, упомянутые в описании
ISO 4037-3:2019
ДействующийRadiological protection — X and gamma reference radiation for calibrating dosemeters and doserate meters and…
Overview ISO 4037-3:2019 - Radiological protection - Part 3 - provides detailed procedures and data for the calibration of area and personal dosemeters and doserate meters using X‑ and gamma‑ray refe…
ISO 6980-2:2022
ОтменёнNuclear energy — Reference beta-particle radiation — Part 2: Calibration fundamentals related to basic quanti…
Overview - ISO 6980-2:2022 (beta-particle radiation calibration fundamentals) ISO 6980-2:2022 specifies methods for measuring the absorbed-dose rate in a tissue-equivalent slab phantom for ISO 6980 r…
ISO 8529-2:2000
ДействующийReference neutron radiations — Part 2: Calibration fundamentals of radiation protection devices related to th…
Overview ISO 8529-2:2000 - "Reference neutron radiations - Part 2" defines the calibration fundamentals used to realize reference neutron radiation fields for the calibration of radiation protection…