This document, used in conjunction with ISO 834-1, specifies a method for determining the fire resistance of door and shutter assemblies designed primarily for installation within openings incorporated in vertical separating elements, such as — hinged and pivoted doors, — horizontally sliding and vertically sliding doors, including articulated sliding doors and sectional doors, — steel single-skin folding shutters (un-insulated), — other sliding, folding doors, — tilting doors, — rolling shutter doors, — removable panels in walls, — self-closing openable windows. Requirements are included for mechanical pre-conditioning, e.g. "cycling" of door and shutter assemblies prior to the conduct of the fire-resistance test.
Abstract
Overview
ISO 3008-1:2019 - Fire resistance tests - Door and shutter assemblies - Part 1: General requirements specifies a standardized method for determining the fire resistance of door and shutter assemblies intended for vertical separating elements. Used together with ISO 834-1, this document covers a wide range of assemblies (hinged, sliding, rolling, folding, tilting doors, removable panels, air transfer grilles and self-closing openable windows) and sets out general test arrangements, safety and conditioning requirements for reliable fire-resistance testing.
Key Topics
- Scope and terminology: Definitions relevant to door and shutter assemblies, associated and supporting constructions, gaps, cills and door hardware.
- Test specimen requirements: Guidance on specimen size, number, design, construction and verification prior to testing.
- Installation and supporting construction: How to mount test specimens, detailing associated and supporting constructions, restraints, and allowable gaps to reproduce realistic boundary conditions.
- Conditioning / pre-conditioning: Requirements for moisture conditioning and mechanical pre-conditioning (e.g., “cycling” of doors/shutters) to simulate in-service wear before fire testing.
- Instrumentation and measurements:
- Furnace and unexposed-face temperature measurement (thermocouples and locations)
- Maximum temperature monitoring and door frame temperature
- Pressure and heat-flux measurement methods
- Deflection and retention-force measurement procedures
- Test procedure and performance criteria: Procedures for conducting the fire-resistance test and evaluating performance against integrity and insulation criteria.
- Reporting and field of direct application: Required test report content and guidance on applicability of test results to timber, steel, glazed constructions and fixings/hardware.
- Safety: Explicit cautions about hazards from smoke, gases and mechanical risks during fire testing.
Applications and Users
ISO 3008-1:2019 is designed for practical use by:
- Fire test laboratories performing standardized fire-resistance testing of doors and shutters
- Manufacturers of fire doors, rolling shutters and associated hardware for product development and certification
- Fire safety engineers and consultants evaluating building compartmentation and egress performance
- Specifiers, architects and building code officials referencing validated fire performance for compliance and acceptance
- Third-party certification bodies assessing conformity with fire-resistance ratings
Using ISO 3008-1 ensures reproducible, comparable test results for fire-resistance performance of door and shutter assemblies, supporting regulatory compliance and safer building design.
Related standards
- ISO 834-1 - Fire-resistance tests - Elements of building construction - Part 1: General requirements (used in conjunction)
- ISO 834-8 - Specific requirements for non-loadbearing vertical separating elements
- ISO 3009 - Fire-resistance tests - Glazed elements
- ISO 13943 - Fire safety - Vocabulary
Keywords: ISO 3008-1:2019, fire resistance tests, door and shutter assemblies, fire-resistance testing, mechanical pre-conditioning, ISO 834-1.
Технические детали
- Технический комитет
- ISO/TC 92/SC 2 - Fire containment
- SKU
- ISO 3008-1:2019
Похожие стандарты
Стандарты, упомянутые в описании
ISO 834-10:2014
ДействующийFire resistance tests — Elements of building construction — Part 10: Specific requirements to determine the c…
Overview ISO 834-10:2014 - Fire resistance tests - Elements of building construction - Part 10 - specifies test methods to determine the contribution of applied fire protection materials to structura…
ISO 3008:1976
ОтменёнFire-resistance tests — Door and shutter assemblies
ISO 834-8:2002
ДействующийFire-resistance tests — Elements of building construction — Part 8: Specific requirements for non-loadbearing…
Overview - ISO 834-8:2002 (fire-resistance tests for non-loadbearing walls) ISO 834-8:2002 defines specific procedures for determining the fire resistance of non-loadbearing vertical separating eleme…