ISO 3924:2019
Petroleum products — Determination of boiling range distribution — Gas chromatography method
Petroleum products — Determination of boiling range distribution — Gas chromatography method
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 39
- Дата публикации:
- 19 июля 2019 г.
- Издание:
- ISO IS 3924 edition 5 version 1
- ICS:
- 75.080
This document specifies a method for the determination of the boiling range distribution of petroleum products. The method is applicable to petroleum products and fractions with a final boiling point of 538 °C or lower at atmospheric pressure as determined by this document. This document does not apply to gasoline samples or gasoline components. The method is limited to products having a boiling range greater than 55 °C and having a vapour pressure sufficiently low to permit sampling at ambient temperature. The document describes two procedures. a) Procedure A allows a larger selection of columns and analysis conditions, such as packed and capillary columns as well as a thermal conductivity detector in addition to the flame ionization detector. Analysis times range from 14 min to 60 min. b) Procedure B is restricted to only three capillary columns and requires no sample dilution. The analysis time is reduced to about 8 min. Both procedures have been successfully applied to samples containing fatty acid methyl esters (FAME) up to 20 % (volume fraction). NOTE For the purposes of this document, the terms "% (mass fraction)" and "% (volume fraction)" are used to represent the mass fraction (µ), the volume fraction (φ) of a material.
Abstract
Overview
ISO 3924:2019 - Petroleum products - Determination of boiling range distribution - Gas chromatography method specifies a gas‑chromatographic (GC) procedure to determine the boiling range distribution of petroleum products and fractions with a final boiling point ≤ 538 °C. The method excludes gasoline and gasoline components and is intended for products with a boiling range > 55 °C and vapour pressure low enough for ambient‑temperature sampling. ISO 3924:2019 defines two GC procedures (A and B), calibration and reporting conventions (IBP, T10–T90, FBP), and precision/bias information.
Key topics and technical requirements
- Two procedures
- Procedure A: Flexible - packed or capillary columns, non‑polar stationary phases (e.g., polydimethylsiloxane or silicone gum rubbers), detectors FID or TCD; analysis time ~14–60 min.
- Procedure B: Accelerated - restricted to three capillary columns, no sample dilution, fast analysis (~8 min).
- Principle: Temperature‑programmed GC separates hydrocarbons by increasing boiling point; chromatogram area is converted to boiling temperatures using a retention‑time vs boiling‑point calibration.
- Calibration: Uses accurately weighed n‑alkane mixtures (typical C5–C44 components) in carbon disulfide; different concentrations for packed vs capillary columns; sample peaks (n‑alkanes) can aid calibration.
- Instruments & materials: Non‑polar stationary phases, solid supports for packed columns, carrier gas purity ≥ 99.995% (helium preferred for FID/TCD); hydrogen and nitrogen options discussed in Annexes E and F.
- Data outputs & definitions: IBP, T10/T30/T50/T70/T90, FBP based on percent area under chromatogram; slice rate, peak skewness and resolution checks required.
- Scope limits & compatibility: Applicable to samples containing up to ~20% FAME by volume; safety cautions for compressed gases (helium, nitrogen) and flammable hydrogen.
Practical applications and users
- Who uses ISO 3924:2019
- Petroleum and petrochemical laboratories
- Refinery QC and process control teams
- Fuel analytics labs testing middle‑distillate and lubricant fractions
- Biodiesel/fuel blending quality control (FAME compatibility)
- Standards bodies and method validation scientists
- Why use it
- Rapid, reproducible boiling range distribution by GC as an alternative/complement to physical distillation
- Fast throughput (especially Procedure B) for routine QC
- Useful for product specification, blend design, regulatory compliance and correlation to physical distillation (see Annex A)
Related standards
- ISO 3170, ISO 3171 - sampling of petroleum liquids (normative references)
- ISO 3405 - physical distillation correlation (Annex A assists conversion)
- Historical equivalence: IP 406 and ASTM D2887 (method origins)
- Annexes in ISO 3924:2019 cover n‑alkane boiling points, carrier gas alternatives, precision, and bias.
Keywords: ISO 3924:2019, boiling range distribution, gas chromatography method, petroleum products, Procedure A, Procedure B, GC calibration, n‑alkanes, FAME, fuel quality control.
Технические детали
- Технический комитет
- ISO/TC 28 - Petroleum and related products, fuels and lubricants from natural or synthetic sources
- SKU
- ISO 3924:2019
Похожие стандарты
Стандарты, упомянутые в описании