ISO 4064-5:2014
Water meters for cold potable water and hot water — Part 5: Installation requirements
Water meters for cold potable water and hot water — Part 5: Installation requirements
- Статус документа:
- Отменён
- Формат:
- Электронный (PDF)
- Количество страниц:
- 12
- Дата публикации:
- 26 мая 2014 г.
- Издание:
- ISO IS 4064 edition 1 version 1
- ICS:
- 91.140.60
ISO 4064-5:2014 applies to water meters used to meter the volume of cold potable water and hot water flowing through a fully charged, closed conduit. These water meters incorporate devices which indicate the integrated volume. ISO 4064-5:2014 specifies criteria for the selection of single, combination and concentric water meters, associated fittings, installation, special requirements for meters, and the first operation of new or repaired meters to ensure accurate constant measurement and reliable reading of the meter. In addition to meters based on mechanical principles, ISO 4064-5:2014 also applies to water meters based on electrical or electronic principles, and to water meters based on mechanical principles incorporating electronic devices, used to measure the volume of cold potable water and hot water. It also applies to electronic ancillary devices. Ancillary devices are optional. However, national or international regulations may make some ancillary devices mandatory in relation to the utilization of the water meter. The recommendations of ISO 4064-5:2014 apply to water meters, irrespective of technology, defined as integrating measuring instruments continuously determining the volume of water flowing through them.
Abstract
Overview
ISO 4064-5:2014 - "Water meters for cold potable water and hot water - Part 5: Installation requirements" defines installation, selection and first-operation requirements for water meters used in fully charged, closed conduits. The standard applies to mechanical, electrical and electronic water meters (including hybrid mechanical/electronic types) and to optional electronic ancillary devices. Its purpose is to ensure accurate, reliable volume measurement and safe, maintainable meter installations for cold potable and hot water systems.
Key topics and requirements
-
Scope and applicability
- Covers single, combination and concentric meters for cold potable water and hot water.
- Applies irrespective of metering technology (mechanical, electromagnetic, electronic).
-
Selection criteria
- Choose meter type and size based on available supply pressure, water temperature and quality (suspended particles), acceptable pressure loss, expected flow rates (as defined in ISO 4064‑1), space constraints and environmental conditions (vibration, humidity, electromagnetic disturbances, etc.).
- Manufacturer must provide influence factors and rated operating conditions to aid selection.
-
Associated fittings (minimum recommendations)
- Upstream: stopcock/valve, flow straightening or straight pipe length, strainer, and a sealing means to detect unauthorized removal.
- Downstream: adjustable length device (recommended for meters with Q ≥ 16 m3/h), drain/pressure monitoring device, stopcock for Q > 4.0 m3/h, and check valve where required.
-
Installation requirements
- Accessibility for reading, maintenance and removal (special provisions if meter mass > 25 kg).
- Meter must remain full of water; install upstream air release if air ingress is possible.
- Protect meters from shock, vibration, thermal extremes, flooding and corrosion; provide anchoring to avoid pipe thrust when meter is disconnected.
- Orientation limits, earthing/shunt provisions, and avoidance of hydraulic disturbances (cavitation, surge, water hammer) are specified.
-
Groups and parallel operation
- Guidance for parallel or multiple meter arrangements to avoid exceeding individual meter limits and to minimize interaction (pressure surges, vibrations).
- Compatibility by pressure loss, flow range and maximum working pressure is recommended.
-
First operation
- Procedures for commissioning new or repaired meters to verify accurate operation and reliable readings (including protection, safety and access provisions).
Practical applications and users
ISO 4064-5:2014 is used by:
- Water utility engineers and asset managers specifying and commissioning meters
- Meter manufacturers and suppliers for product documentation and installation guidance
- Plumbing contractors and installers for compliant meter installation
- Inspection bodies and calibration laboratories assessing installation conformity
- Facility managers and building services engineers planning metering in buildings and plants
Keywords: ISO 4064-5:2014, water meters installation requirements, potable water metering, hot water meters, electromagnetic meters, flow meter installation, metering standards.
Related standards
- ISO 4064-1:2014 (metrological and technical requirements)
- ISO 4064 (other parts: test methods, report format, non-metrological requirements)
- ISO 6817 (electromagnetic flowmeters)
- OIML R 49-1 (equivalent metrological guidance)
Технические детали
- Технический комитет
- ISO/TC 30/SC 7 - Volume methods including water meters
- SKU
- ISO 4064-5:2014
Похожие стандарты
Стандарты, упомянутые в описании
ISO 4064-1:2014
ОтменёнWater meters for cold potable water and hot water — Part 1: Metrological and technical requirements
Overview ISO 4064-1:2014 - Water meters for cold potable water and hot water: Part 1 - Metrological and technical requirements specifies the metrological and technical rules for water meters used in…
ISO 4064-1:1977
ОтменёнMeasurement of water flow in closed conduits — Meters for cold potable water — Part 1: Specification
ISO 4064-4:2024
ДействующийWater meters for cold potable water and hot water — Part 4: Non-metrological requirements not covered in ISO…
Overview ISO 4064-4:2024 - "Water meters for cold potable water and hot water - Part 4: Non‑metrological requirements not covered in ISO 4064‑1" defines the non‑metrological technical requirements fo…