ISO 4965-1:2012
Metallic materials — Dynamic force calibration for uniaxial fatigue testing — Part 1: Testing systems
Metallic materials — Dynamic force calibration for uniaxial fatigue testing — Part 1: Testing systems
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 13
- Дата публикации:
- 6 июля 2012 г.
- Издание:
- ISO IS 4965 edition 1 version 1
- ICS:
- 77.040.10
ISO 4965-1:2012 describes two methods for determining the relationship between the dynamic force range applied to a test-piece in a uniaxial, sinusoidal, constant amplitude test and the force range indicated by the testing system. These methods are applicable to dynamic testing systems operating away from system resonant frequencies and are relevant to testing systems where the dynamic force measurement errors are either unknown or where they are expected to exceed 1 % of the applied force range. The dynamic force measurement errors are determined by comparison of the peak forces indicated by the dynamic testing system with those measured by the strain gauged dynamic calibration device (DCD). This DCD has previously undergone static calibration against the testing system indicator. For Method A (Replica test-piece method), the dynamic calibration is applicable over the validated range of frequencies for that type of test-piece only. A frequency-dependent correction factor is applicable for the correction of dynamic force measurement errors of up to 10 % of dynamic force range. By using such a correction factor, the actual test specimen dynamic force measurement error will be reduced to less than 1 % of the dynamic force range. For Method B (Compliance envelope method), the dynamic calibration is applicable over the range of test frequencies validated for test-pieces whose compliance lies between those of the two DCDs. No correction factor is applicable, as Method B does not permit dynamic force measurement errors above 1 % of the dynamic force range.
Abstract
Overview
ISO 4965-1:2012 - "Metallic materials - Dynamic force calibration for uniaxial fatigue testing - Part 1: Testing systems" specifies procedures to determine and correct the relationship between the dynamic force applied to a uniaxial fatigue test-piece and the force indicated by the testing system. The standard defines two calibration methods using a strain‑gauged Dynamic Calibration Device (DCD) and applies to systems operating away from resonant frequencies where dynamic force measurement errors are unknown or expected to exceed 1% of the applied force range.
Key topics and technical requirements
- Two calibration methods
- Method A (Replica test-piece method): Uses a DCD that replicates specimen mass and compliance. A frequency‑dependent correction factor can correct indicated force errors up to 10% down to <1%.
- Method B (Compliance envelope method): Uses two DCDs of different compliance to establish an operating envelope. No corrective factor; errors are kept ≤1% for specimens whose compliance lies between the two DCDs.
- DCD characteristics: Strain‑gauged device previously statically calibrated against the testing system (traceable to electrical standards).
- Frequency and resonance: Calibrations are valid only away from system resonant frequencies; calibration must cover the range of intended test frequencies and consider instrumentation bandwidth and filtering.
- Dynamic force range and linearity: Dynamic ranges used must be within 10–100% of DCD rating and within the machine’s static calibration range. A linear relationship between applied force and actuator displacement at each frequency is required; otherwise multiple force-range calibrations are necessary.
- Environmental and setup controls: Ambient temperature, load‑train mass and compliance, filters, and the exact test‑fixture configuration must be recorded and controlled for valid calibration.
- Reporting and re‑calibration: The standard specifies required reporting items and refers to Annex A (guidance on re‑calibration) and Annex B (bandwidth estimation).
Applications and users
ISO 4965-1 is intended for:
- Materials testing laboratories performing uniaxial fatigue testing
- Calibration laboratories and instrument manufacturers validating dynamic testing systems
- R&D and quality assurance teams in aerospace, automotive, power generation, and metallurgy who require reliable fatigue data
- Test system designers and metrologists concerned with dynamic force measurement accuracy
Benefits include improved traceability of dynamic force measurements, reduced force measurement errors during cyclic tests, and greater confidence in fatigue life and S–N data.
Related standards
- ISO 4965-2: Dynamic calibration device (DCD) instrumentation
- ISO 7500-1: Verification of static uniaxial testing machines (force measurement system)
Keywords: ISO 4965-1:2012, dynamic force calibration, uniaxial fatigue testing, dynamic calibration device (DCD), replica test-piece, compliance envelope, force measurement errors, testing systems.
Технические детали
- Технический комитет
- ISO/TC 164/SC 4 - Fatigue, fracture and toughness testing
- SKU
- ISO 4965-1:2012
Похожие стандарты
Упомянутые в описании и другие стандарты ISO
ISO 4965-2:2012
ДействующийMetallic materials — Dynamic force calibration for uniaxial fatigue testing — Part 2: Dynamic calibration dev…
Overview ISO 4965-2:2012 specifies the calibration procedure and instrumentation requirements for a Dynamic Calibration Device (DCD) used to measure forces in uniaxial fatigue testing. This part of I…
ISO 7500-1:2018
ДействующийMetallic materials — Calibration and verification of static uniaxial testing machines — Part 1: Tension/compr…
Overview ISO 7500-1:2018 - "Metallic materials - Calibration and verification of static uniaxial testing machines - Part 1: Tension/compression testing machines - Calibration and verification of the…
ISO 8212:1986
ОтменёнSoaps and detergents — Techniques of sampling during manufacture
Overview Standard Reference: ISO 8212:1986 Title: Soaps and detergents - Techniques of sampling during manufacture ISO 8212:1986 defines standardized techniques for taking representative samples of s…
ISO 20662:2020
ДействующийShips and marine technology — Hopper dredger supervisory and control systems
Overview ISO 20662:2020 - Ships and marine technology: Hopper dredger supervisory and control systems (HD‑SCS) - specifies the components, structure, general requirements, and functional requirements…
ISO 3021:2023
ДействующийAdventure tourism — Hiking and trekking activities — Requirements and recommendations
Overview ISO 3021:2023 - Adventure tourism: Hiking and trekking activities - Requirements and recommendations defines safety-focused requirements and recommendations for hiking and trekking offered a…
ISO 3826-2:2008
ДействующийPlastics collapsible containers for human blood and blood components — Part 2: Graphical symbols for use on l…
Overview ISO 3826-2:2008 - "Plastics collapsible containers for human blood and blood components - Part 2: Graphical symbols for use on labels and instruction leaflets" defines a system of internatio…
ISO/IEC 24730-1:2014
ДействующийInformation technology — Real-time locating systems (RTLS) — Part 1: Application programming interface (API)
Overview ISO/IEC 24730-1:2014 specifies the Application Programming Interface (API) for Real‑Time Locating Systems (RTLS). The standard defines a minimal, interoperable boundary that lets application…
ISO 8668-5:1992
ДействующийAircraft — Terminal junction systems — Part 5: Detail specification for type 3 system
Overview - ISO 8668-5:1992 (Aircraft terminal junction systems, Type 3) ISO 8668-5:1992 defines the detail specification for Type 3 Terminal Junction Systems (TJS) used in aircraft electrical install…