ISO 5167-2:2022
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full — Part 2: Orifice plates
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full — Part 2: Orifice plates
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 53
- Дата публикации:
- 16 июня 2022 г.
- Издание:
- ISO IS 5167 edition 2 version 1
- ICS:
- 17.120.10
This document specifies the geometry and method of use (installation and operating conditions) of orifice plates when they are inserted in a conduit running full to determine the flow rate of the fluid flowing in the conduit. This document also provides background information for calculating the flow rate and is applicable in conjunction with the requirements given in ISO 5167‑1. This document is applicable to primary devices having an orifice plate used with flange pressure tappings, or with corner pressure tappings, or with D and D/2 pressure tappings. Other pressure tappings such as “vena contracta” and pipe tappings are not covered by this document. This document is applicable only to a flow which remains subsonic throughout the measuring section and where the fluid can be considered as single phase. It is not applicable to the measurement of pulsating flow[1]. It does not cover the use of orifice plates in pipe sizes less than 50 mm or more than 1 000 mm, or where the pipe Reynolds numbers are below 5 000.
Abstract
Overview
ISO 5167-2:2022 - part of the ISO 5167 series - defines how to measure fluid flow in full circular conduits using orifice plates as differential-pressure primary devices. The standard specifies orifice-plate geometry, allowable pressure-tap locations, installation and operating conditions, and the calculation background (discharge coefficients, expansibility factors and uncertainty). It applies only to subsonic, single‑phase flows and is intended to be used together with ISO 5167‑1 (general principles).
Key topics and technical requirements
- Orifice plate geometry and manufacture: required shapes, edge forms, thickness limits and material/manufacture considerations for reliable measurement.
- Pressure tappings covered: flange tappings, corner tappings, and D / D/2 tappings. (Other tappings such as “vena contracta” and pipe tappings are excluded.)
- Calculation basis: mass and volumetric flow are derived from the measured differential pressure together with the discharge coefficient (C), expansibility factor (ε), fluid density (ρ), orifice diameter (d) and beta ratio (β).
- Limits of use: not applicable for pulsating flow; pipe sizes < 50 mm or > 1 000 mm are excluded; Reynolds numbers below 5 000 are excluded; flow must remain subsonic and single‑phase.
- Installation requirements: minimum upstream/downstream straight lengths, pipe circularity/cylindricity, carrier rings and gasket/fixing methods to minimise measurement errors.
- Flow conditioners: guidance on acceptable flow straighteners (e.g., tube bundles, Zanker-type plates) to stabilise upstream profiles where required.
- Calibration and uncertainty: procedures for flow calibration of orifice meters, test-facility and meter installation guidance, and methods for uncertainty analysis.
- Supplementary material: informative annexes provide tables of discharge coefficients/expansibility factors and details about flow conditioners.
Practical applications and who uses this standard
ISO 5167-2 is used by:
- Flow metrology and instrumentation engineers specifying or verifying orifice‑plate meters.
- Calibration laboratories conducting flow calibrations and uncertainty analysis.
- Process, petrochemical, water/wastewater, and utility engineers requiring standardized differential‑pressure flow measurement.
- Procurement and QA teams ensuring installed meters meet recognized international measurement requirements.
Using ISO 5167-2 helps achieve repeatable, traceable flow measurements, reduce installation-related errors, and support coherent uncertainty estimates for process control, custody transfer and regulatory reporting.
Related standards
- ISO 5167-1 (general principles and requirements)
- ISO 4006 (vocabulary and symbols)
- ISO 5168 (uncertainty evaluation procedures)
- ISO/IEC Guide 98-3 (GUM - expression of uncertainty)
Keywords: ISO 5167-2:2022, orifice plate flow measurement, differential pressure devices, discharge coefficient, flow calibration, pressure tappings, Reynolds number, installation requirements, flow conditioners.
Технические детали
- Технический комитет
- ISO/TC 30/SC 2 - Pressure differential devices
- SKU
- ISO 5167-2:2022
Похожие стандарты
Стандарты, упомянутые в описании
ISO/TR 9464:2023
ДействующийGuidelines for the use of ISO 5167:2022
Overview ISO/TR 9464:2023 - Guidelines for the use of ISO 5167:2022 - is a Technical Report that helps users correctly apply the ISO 5167 series for flow measurement in circular conduits using differ…
ISO 5167-1:2003
ОтменёнMeasurement of fluid flow by means of pressure differential devices inserted in circular cross-section condui…
ISO 4006:1991
ДействующийMeasurement of fluid flow in closed conduits — Vocabulary and symbols
Overview ISO 4006:1991 - Measurement of fluid flow in closed conduits - Vocabulary and symbols - is an ISO international standard that defines recommended terms and corresponding symbols used in the…
ISO 5168:2005
ДействующийMeasurement of fluid flow — Procedures for the evaluation of uncertainties
Overview ISO 5168:2005 - Measurement of fluid flow: Procedures for the evaluation of uncertainties provides a standardized framework for quantifying the uncertainty in measured fluid flow-rate or flo…