ISO 52010-1:2017
Energy performance of buildings — External climatic conditions — Part 1: Conversion of climatic data for energy calculations
Energy performance of buildings — External climatic conditions — Part 1: Conversion of climatic data for energy calculations
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 35
- Дата публикации:
- 21 июня 2017 г.
- Издание:
- ISO IS 52010 edition 1 version 1
- ICS:
- 91.120.10
ISO 52010-1:2017 specifies a calculation procedure for the conversion of climatic data for energy calculations. The main element in ISO 52010-1:2017 is the calculation of solar irradiance on a surface with arbitrary orientation and tilt. A simple method for conversion of solar irradiance to illuminance is also provided. The solar irradiance and illuminance on an arbitrary surface are applicable as input for energy and daylighting calculations, for building elements (such as roofs, facades and windows) and for components of technical building systems (such as thermal solar collectors, PV panels). Other parameters of climatic data needed to assess the thermal and moisture performance of buildings, building elements or technical building systems [like wind, temperature, moisture and long-wave (thermal) radiation] are to be obtained according to the procedures in ISO 15927‑4. These data are listed in ISO 52010-1:2017 as input and passed on as output without any conversion. NOTE 1 The reason for passing these data via ISO 52010-1:2017 is to have one single and consistent source for all EPB standards and to enable any conversion or other treatment if needed for specific application. NOTE 2 Table 1 in the Introduction shows the relative position of ISO 52010-1:2017 within the set of EPB standards in the context of the modular structure as set out in ISO 52000-1.
Abstract
Overview
ISO 52010-1:2017 - "Energy performance of buildings - External climatic conditions - Part 1: Conversion of climatic data for energy calculations" defines a standardised procedure to convert climatic data into the forms needed for building energy and daylighting calculations. The standard’s central function is the calculation of solar irradiance on a surface with arbitrary orientation and tilt and a simple method to convert solar irradiance to illuminance. It provides a consistent, single source of converted climatic inputs for the suite of EPB (energy performance of buildings) standards.
Key topics and technical requirements
- Solar irradiance on inclined surfaces: Methodology to compute total solar irradiance for any tilt and orientation (including sun path, direct/diffuse split and ground reflectivity).
- Illuminance conversion: A simple conversion approach from solar irradiance to daylight illuminance for use in lighting and daylighting assessments.
- Shading and geometry: Procedures for assessing shading from external objects and the geometrical parameters required (orientation, tilt, obstructions).
- Input/output handling: Definition of input climatic datasets, time intervals, constants and physical data; converted outputs intended for hourly energy calculations.
- Integration and consistency: Non-solar climatic parameters (wind, temperature, moisture, long-wave radiation) are passed through unchanged from ISO 15927‑4 to keep a single consistent source for EPB standards.
- Quality control and compliance: Sections on quality control and compliance checks to ensure reliable conversions.
- Annexes: Normative template (Annex A) for specifying choices and informative default options (Annex B) for national or project-level adaptation.
Practical applications and users
ISO 52010-1:2017 is intended for practitioners who need standardized climatic inputs for energy performance modelling and daylight analysis:
- Architects and building designers using dynamic thermal and daylighting simulation tools.
- Building services engineers sizing or assessing thermal solar collectors, PV panels, glazing, façades and roofs.
- Energy assessors and regulators establishing consistent inputs for compliance, certification and policy (national annexes can define mandatory choices).
- Software developers implementing EPB-compliant weather conversion modules.
Typical uses include preparing hourly input weather files, computing incident solar gains on building elements, and supplying illuminance or irradiance inputs for lighting control and PV yield models.
Related standards
- ISO 15927‑4 - Hourly climatic data for annual heating and cooling assessments (used for wind, temperature, moisture, long-wave radiation).
- ISO 52000‑1 - Overarching EPB assessment framework.
- ISO 7345, ISO 9488 - Definitions and solar energy vocabulary.
- ISO 52016‑1 and ISO/TR 52010‑2 - Related calculation methods and technical reports supporting EPB methodology.
Keywords: ISO 52010-1:2017, energy performance of buildings, external climatic conditions, solar irradiance, illuminance, climatic data conversion, EPB standards, building energy calculations, PV, thermal solar collectors.
Технические детали
- Технический комитет
- ISO/TC 163/SC 2 - Calculation methods
- SKU
- ISO 52010-1:2017
Похожие стандарты
Стандарты, упомянутые в описании
BS EN ISO 15927-4:2005
ДействующийHygrothermal performance of buildings. Calculation and presentation of climatic data. Hourly data for assessi…
ISO 52000-1:2017
ДействующийEnergy performance of buildings — Overarching EPB assessment — Part 1: General framework and procedures
Overview ISO 52000-1:2017 - Energy performance of buildings - Overarching EPB assessment - Part 1: General framework and procedures - defines a systematic, modular framework for assessing the energy…
ISO 7345:2018
ДействующийThermal performance of buildings and building components — Physical quantities and definitions
Overview ISO 7345:2018 - "Thermal performance of buildings and building components - Physical quantities and definitions" is an ISO standard that defines the physical quantities, symbols and units us…
ISO 9488:1999
ОтменёнSolar energy — Vocabulary
ISO 52016-1:2017
ДействующийEnergy performance of buildings — Energy needs for heating and cooling, internal temperatures and sensible an…
Overview ISO 52016-1:2017 - “Energy performance of buildings - Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads - Part 1: Calculation procedures” - defin…
ISO/TR 52010-2:2017
ДействующийEnergy performance of buildings - External climatic conditions — Part 2: Explanation and justification of ISO…
Overview ISO/TR 52010-2:2017 is an informative technical report that explains and justifies the contents of ISO 52010‑1 (the EPB - Energy Performance of Buildings - climatic data standard). It does n…