ISO 5799:1991
Photography — Direct-exposing medical and dental radiographic film/process systems — Determination of ISO speed and ISO average gradient
Photography — Direct-exposing medical and dental radiographic film/process systems — Determination of ISO speed and ISO average gradient
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 10
- Дата публикации:
- 8 августа 1991 г.
- Издание:
- ISO IS 5799 edition 2 version 1
- ICS:
- 37.040.25
Specifies measuring methods so that the film/process system can be obtained reproducibly and can also be compared with those of other systems. Describes sensitometric procedures for films exposed directly to X-rays. This second edition cancels and replaces the first edition (1981).
Abstract
Overview
ISO 5799:1991 - Photography: Direct-exposing medical and dental radiographic film/process systems - specifies standardized methods to determine ISO Speed and ISO average gradient for film/process combinations directly exposed to X‑rays. The standard ensures reproducible sensitometric measurements so film/process performance can be compared between products and suppliers. This second edition updates units (adopting the gray for air kerma) and aligns speed/gradient tables with other radiographic film standards.
Key topics and technical requirements
- Scope: Sensitometric procedures for films exposed directly to X‑ray radiation in medical and dental radiography (excluding mammography).
- Measurement basis: Uses air kerma (gray, Gy) as the exposure quantity and derives ISO Speed and average gradient from sensitometric curves (density vs. log10 air kerma).
- Sampling & storage:
- Samples stored per manufacturer recommendations to simulate typical product age.
- Test temperature: 23 °C ± 5 °C; relative humidity 50 % ± 20 %.
- Exposure & densitometry:
- Instrumentation & calibration:
- Air kerma measured with an ionization chamber calibrated for the radiation quality used.
- Ion chamber/monitoring recommendations to reduce variability and correct for fluctuations.
- Processing:
- No single processing recipe is mandated; manufacturers’ recommended processes must be reported because Speed and gradient depend on development conditions.
- Processing to begin within 30 minutes to 8 hours after exposure.
- Quality controls:
- Minimize scattered radiation (scattered portion ≤ 5 % of primary).
- Film holders designed for <2 % absorption.
- Output & designation:
- ISO Speed and ISO average gradient are calculated from averaged sensitometric data and reported with the ISO designation (e.g., ISO X D 100 for X‑ray direct exposure techniques).
- Informative annexes: Calibration parameters and measurement reproducibility guidance.
Applications and users
ISO 5799:1991 is used by:
- Radiographic film manufacturers for product specification and labeling (ISO Speed / average gradient).
- Medical physicists and quality assurance teams establishing image receptor performance and procurement criteria.
- Dental imaging suppliers and laboratory technicians validating film/process combinations.
- Test laboratories performing comparative sensitometry and conformance testing.
Keywords: ISO 5799:1991, radiographic film, ISO Speed, ISO average gradient, air kerma, sensitometry, densitometry, medical radiography, dental radiography, X‑ray exposure.
Related standards
Технические детали
- Технический комитет
- ISO/TC 42 - Photography
- SKU
- ISO 5799:1991
Похожие стандарты
Стандарты, упомянутые в описании
ISO 5249:1988
ДействующийTextile machinery and accessories — Guide rollers for dyeing and finishing machinery — Main dimensions
Overview ISO 5249:1988 establishes standardized main dimensions and performance requirements for steel guide rollers used in dyeing and finishing machinery within the textile industry. This internati…
ISO 532:1975
ОтменёнAcoustics — Method for calculating loudness level
ISO 5196-1:1980
ДействующийMagnesium alloys — Determination of thorium — Part 1: Gravimetric method
Overview ISO 5196-1:1980 - "Magnesium alloys - Determination of thorium - Part 1: Gravimetric method" specifies a gravimetric chemical-analysis procedure to quantify thorium in magnesium alloys. Publ…
ISO 4037-3:2019
ДействующийRadiological protection — X and gamma reference radiation for calibrating dosemeters and doserate meters and…
Overview ISO 4037-3:2019 - Radiological protection - Part 3 - provides detailed procedures and data for the calibration of area and personal dosemeters and doserate meters using X‑ and gamma‑ray refe…