ISO 5925:2025
Smoke-control door, shutter assemblies and self-closing glazed elements — Ambient-temperature and medium-temperature leakage tests
Smoke-control door, shutter assemblies and self-closing glazed elements — Ambient-temperature and medium-temperature leakage tests
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 28
- Дата публикации:
- 18 декабря 2025 г.
- Издание:
- ISO IS 5925 edition 3 version 1
- ICS:
- 13.220.20
This document describes a test that determines the rate of leakage of ambient (cold) and medium (warm) temperature smoke from one side of door and shutter assemblies to the other under the specified test conditions. This test method is applicable to door and shutter assemblies and self-closing operable glazed elements of different configurations intended for the purpose of controlling the passage of smoke in case of fire. Wherever door and shutter assemblies are referred to in this document, it also applies to self-closing glazed elements. The fire resistance of glazed elements is determined by tests in accordance with ISO 3009. The acceptable leakage rates for different situations are not addressed in this document, but rather are specified by the regulations of the controlling authorities.
Abstract
Overview
ISO 5925:2025 specifies a standardized test method for measuring smoke leakage through smoke-control door and shutter assemblies and self-closing operable glazed elements. The standard covers both ambient-temperature (cold) and medium-temperature (warm) leakage tests, defining test apparatus, instrumentation, specimen preparation, procedures, observations and reporting. ISO 5925:2025 provides repeatable, laboratory-based methods to determine the leakage rate (m3/h) of smoke under defined differential pressure and temperature conditions. The standard does not set acceptable leakage limits; those are determined by regulators or project specifications.
Key topics and technical requirements
- Scope: Applies to door/shutter assemblies and self-closing glazed elements intended for smoke control. Fire resistance for glazed elements is addressed in ISO 3009.
- Test conditions:
- Ambient temperature: 20 ± 10 °C.
- Medium temperature: 200 ± 10 °C.
- Test chamber and apparatus: Typical opening around 3 m × 3 m (smaller for single-leaf doors). Apparatus leakage q_a shall not exceed 7 m3/h. Air supply/heating must replace leakage up to 55 m3/h and create a differential pressure of at least 55 Pa across the specimen.
- Instrumentation: Differential pressure measured to ±5 Pa or 10% of value; medium-temperature tests use 12 thermocouples arranged in four rows of three for temperature control and monitoring.
- Specimen and procedure: Includes requirements for number, size, construction, conditioning, pre-test analysis, set-up, air leakage measurement, observations and expression of results. Annexes provide test principle, apparatus guidance and commentary on applicability.
- Recent updates (3rd edition): added self-closing glazed elements, medium-temperature tolerance, option to run both medium-temperature tests on same specimen, moisture/evaporation controls, and procedural refinements (outlet valve, post-test operability checks).
Applications and users
ISO 5925 is used to:
- Verify smoke leakage performance of smoke-control doors, shutters and glazed elements.
- Support product development, third‑party certification and type testing in fire safety engineering.
- Provide laboratory data for smoke containment strategies used by architects, fire engineers and building authorities.
Typical users:
- Test laboratories and certification bodies
- Manufacturers of fire and smoke-control doors and glazed assemblies
- Fire safety engineers, consultants and code authorities
- Specifiers and facility managers responsible for passive fire protection
Related standards
- ISO 3009 - fire resistance tests for glazed elements (referenced for fire resistance)
- ISO 834-1 - standardized fire curves and general fire-resistance test requirements
- ISO 3008 series - related fire door standards and guidance
Keywords: ISO 5925, smoke-control door, leakage tests, ambient-temperature, medium-temperature, smoke leakage rate, fire safety, self-closing glazed elements.
Технические детали
- Технический комитет
- ISO/TC 92/SC 2 - Fire containment
- SKU
- ISO 5925:2025
Похожие стандарты
Стандарты, упомянутые в описании
BS ISO 3009:2003
ДействующийFire resistance tests. Elements of building construction. Glazed elements.
ISO 834-10:2014
ДействующийFire resistance tests — Elements of building construction — Part 10: Specific requirements to determine the c…
Overview ISO 834-10:2014 - Fire resistance tests - Elements of building construction - Part 10 - specifies test methods to determine the contribution of applied fire protection materials to structura…