ISO 6944-2:2009
Fire containment — Elements of building construction — Part 2: Kitchen extract ducts
Fire containment — Elements of building construction — Part 2: Kitchen extract ducts
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 17
- Дата публикации:
- 9 июня 2009 г.
- Издание:
- ISO IS 6944 edition 1 version 1
- ICS:
- 13.220.50
ISO 6944-2:2009 establishes a method of test in which kitchen extract ducts are required to provide fire resistance. The requirements are intended to limit the spread of fire from the duct when a fire occurs within the duct and assesses the structural integrity of the duct when a fire occurs in the area surrounding the duct.
Abstract
Overview
ISO 6944-2:2009 - Fire containment: Elements of building construction - Part 2: Kitchen extract ducts specifies standardized test methods to evaluate the fire resistance of commercial kitchen extract (exhaust) ducts. The standard is intended to demonstrate the ability of a duct or duct assembly to limit fire spread when a fire originates either inside the duct (typical grease/duct fire) or outside the duct (room/furnace exposure), and to assess the structural integrity of the duct under these fire conditions.
Key topics and requirements
- Two attack scenarios
- Fire inside the duct: simulated using a gas-fired premix burner attached to an insulated L-shaped combustion chamber that feeds flue gases into the test specimen. The method models grease build-up and the severe temperatures possible in kitchen extract systems.
- Fire outside the duct: exposure uses furnace conditions defined in ISO 834-1 to assess penetration seals and structural restraint when the duct is within a fire-resisting barrier.
- Test specimen scope: vertical and horizontal ducts, with or without branches, including joints, exhaust openings, suspension devices and penetrations.
- Test equipment details (selected, as given in the standard):
- Minimum L-shaped combustion chamber total length: L1 + L2 ≥ 700 mm.
- Combustion chamber internal duct dimensions: minimum 700 mm × 700 mm.
- Ceramic fibre insulation thickness: minimum 50 mm; density ≈ 120 kg/m3 ± 30 kg/m3.
- Duct orifice flow control permitted for large orifice areas (>0.75 m2) with exhaust remaining ≥75% open.
- Instrumentation & conditioning
- Flue gas temperature measured by a thermocouple grid (Type K or Type S Inconel-sheathed thermocouples; tips projecting 25 ± 1.5 mm).
- Unexposed surface temperatures recorded with a minimum of 14 thermocouples on the horizontal section and additional thermocouples at joints and access covers.
- Laboratory ventilation and conditioning requirements (e.g., CO kept <50 µl/l during tests; specified moisture conditioning).
- Safety: cautions on toxic/harmful smoke, mechanical hazards, and post-test cooling are emphasized.
Applications and users
- Manufacturers of commercial kitchen extract ducts, grease management systems and duct insulation.
- Fire test laboratories conducting standardized fire resistance testing.
- Building product certifiers, fire safety engineers, consultants and code officials assessing duct fire containment, penetration seals and compartmentation measures.
- Architects and MEP designers specifying fire-resisting duct systems in commercial kitchens.
Related standards
- ISO 6944-1:2008 - Fire containment - Part 1: Ventilation ducts (related test methods and equipment).
- ISO 834-1 - Fire-resistance tests - General furnace requirements.
- ISO 13943 - Fire safety vocabulary.
Keywords: ISO 6944-2:2009, kitchen extract ducts, fire containment, fire resistance test, fire-resisting ducts, ventilation ducts, fire testing.
Технические детали
- Технический комитет
- ISO/TC 92/SC 2 - Fire containment
- SKU
- ISO 6944-2:2009
Похожие стандарты
Стандарты, упомянутые в описании
ISO 6944-1:2008
ОтменёнFire containment — Elements of building construction — Part 1: Ventilation ducts
ISO 834-10:2014
ДействующийFire resistance tests — Elements of building construction — Part 10: Specific requirements to determine the c…
Overview ISO 834-10:2014 - Fire resistance tests - Elements of building construction - Part 10 - specifies test methods to determine the contribution of applied fire protection materials to structura…