ISO 7105:1985
Liquefied anhydrous ammonia for industrial use — Determination of water content — Karl Fischer method
Liquefied anhydrous ammonia for industrial use — Determination of water content — Karl Fischer method
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 4
- Дата публикации:
- 6 июня 1985 г.
- Издание:
- ISO IS 7105 edition 1 version 1
- ICS:
- 71.060.99
A test portion is evaporated in the presence of ethanediol and the water content of the residue is determined by the Karl Fischer method with direct electrometric measurement. The method is applicable to products having water contents equal to or greater than 50 mg/kg. For water contents greater than 1000 mg/kg it is preferable to dilute the evaporation residue with anhydrous methanol in accordance with ISO 4276 and titrate an aliquot portion of the diluted solution.
Abstract
Overview
ISO 7105:1985 - Liquefied anhydrous ammonia for industrial use - Determination of water content - Karl Fischer method specifies a laboratory procedure for measuring the water content of liquefied anhydrous ammonia using the Karl Fischer direct electrometric titration. The method applies to samples with water contents ≥ 50 mg/kg. For high water levels (> 1 000 mg/kg), the standard recommends diluting the evaporation residue with anhydrous methanol (per ISO 4276) and titrating an aliquot.
Key topics and requirements
- Scope and applicability: Designed for industrial-grade liquefied anhydrous ammonia; applicable from 50 mg/kg upward.
- Principle: Evaporate a weighed test portion in the presence of 1,2-ethanediol (ethyleneglycol) to leave a water/ethanediol residue, then determine water by the Karl Fischer direct electrometric method.
- Reagents and materials: Includes freezing mixture (CO2/methanol), sulfuric acid solution, 1,2-ethanediol (very hygroscopic), methanol/acetic acid mixture, and Karl Fischer reagent of analytical grade.
- Apparatus & sampling: Uses a specified glass collection/test tube assembly, Dewar vessel, and conical flasks to collect liquefied ammonia (follow sampling procedure in ISO 7103). Stopcocks must be PTFE or silicone-greased.
- Procedure highlights:
- Collect and weigh a laboratory sample in a cooled test tube.
- Evaporate ammonia slowly to obtain residue; rinse residue into the Karl Fischer titration vessel using methanol/acetic acid mixture.
- Run a simultaneous blank and perform direct electrometric titration per ISO 760.
- Results & reporting: Water content expressed as percentage by mass of H2O. Test report must include sample ID, method reference, titration volumes (including blank), test portion mass, calculated result and any unusual observations.
- Safety: Emphasizes strong hazards of liquefied anhydrous ammonia (toxic, corrosive, -33.3 °C boiling point). Operations must be performed in a well‑ventilated fume cupboard with appropriate PPE (rubber gloves, apron, full-face/head protection, protective gas‑mask).
Practical applications and users
- Quality control and acceptance testing for industrial ammonia suppliers and users.
- Analytical and calibration laboratories performing routine water determination in bulk ammonia.
- Process engineers and storage/transport specialists monitoring product quality and safety.
- Regulatory and procurement teams requiring standardized, traceable water-content data for compliance, safety, and product specifications.
Related standards
- ISO 760 - Determination of water - Karl Fischer method (general method)
- ISO 4276 - Anhydrous ammonia for industrial use - Evaluation of residue on evaporation (gravimetric method)
- ISO 7103 - Liquefied anhydrous ammonia - Sampling
- ISO 3165 - Safety in sampling
Keywords: ISO 7105:1985, liquefied anhydrous ammonia, water content determination, Karl Fischer method, ethanolediol, methanol dilution, ISO 760, ISO 4276, industrial ammonia testing, water in ammonia.
Технические детали
- Технический комитет
- ISO/TC 47 - Chemistry
- SKU
- ISO 7105:1985
Похожие стандарты
Стандарты, упомянутые в описании
ISO 4276:1978
ОтменёнAnhydrous ammonia for industrial use — Evaluation of residue on evaporation — Gravimetric method
ISO 7103:1982
ДействующийLiquefied anhydrous ammonia for industrial use — Sampling — Taking a laboratory sample
Overview ISO 7103:1982 is an international standard established by the International Organization for Standardization (ISO) that specifies the apparatus and procedure for sampling liquefied anhydrous…
ISO 7609:1985
ДействующийEssential oils — Analysis by gas chromatography on capillary columns — General method
Overview ISO 7609:1985 Essential oils - Analysis by gas chromatography on capillary columns - General method is an international standard developed by ISO Technical Committee 54, Essential Oils. This…
ISO 31657-2:2025
ДействующийPlain bearings — Hydrodynamic plain journal bearings under steady-state conditions — Part 2: Characteristic v…
Overview ISO 31657-2:2025 - Plain bearings - Hydrodynamic plain journal bearings under steady‑state conditions - Part 2 specifies characteristic values required for the safe design and calculation of…