ISO 7885:2010
Dentistry — Sterile injection needles for single use
Dentistry — Sterile injection needles for single use
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 7
- Дата публикации:
- 12 февраля 2010 г.
- Издание:
- ISO IS 7885 edition 3 version 1
- ICS:
- 11.040.25
ISO 7885:2010 gives dimensional and performance requirements for sterile injection needles for single use which are used in dental cartridge syringes complying with ISO 9997 for injection of dental local anaesthetics. It further specifies requirements with respect to their packaging, labelling and colour coding. It does not cover needles for special applications or techniques. Only the materials used for the construction of the needle tubing are specified.
Abstract
Overview
ISO 7885:2010 - "Dentistry - Sterile injection needles for single use" specifies dimensional and performance requirements for sterile dental injection needles designed for use with dental cartridge syringes (ISO 9997). The standard covers needle tubing materials, needle and hub assembly strength, packaging, labelling and colour coding for metric-size needles used to deliver local anaesthetics. It does not cover needles for special techniques, and only the tubing material (per ISO 9626) is prescribed.
Key topics and technical requirements
ISO 7885:2010 defines clear, testable requirements that manufacturers and users must meet:
- Needle tubing material: compliant with ISO 9626 (stainless steel needle tubing).
- Nominal outside diameters: 0.2 mm to 0.5 mm.
- Size designation: expressed as outside diameter × effective length (mm), e.g. 0.4 mm × 34 mm.
- Effective needle length tolerance: within ±10% of manufacturer’s stated length.
- Butt end geometry:
- Butt-end angle: 15° to 55° (measured through needle axis).
- Butt-end length: 9.0 mm to 14.0 mm.
- Needle tip quality: pointed and free from burrs/defects at 2.5× magnification; primary bevel angle within 2° of manufacturer claim.
- Hub performance:
- Union between hub and needle withstands minimum 22 N axial force.
- Socket depth ≥ 5 mm.
- Threaded hubs conform to metric M6 × 0.75; an imperial thread reference is provided in Annex A.
- Colour coding (per ISO 6009) for easy identification:
- 0.20 mm - black
- 0.25 mm - white
- 0.30 mm - yellow
- 0.40 mm - medium grey
- 0.50 mm - orange
- Packaging (primary container): hardpack or softpack that maintains sterility, shows evidence of opening, and allows attaching needle without touching it.
- Sterility: needles must undergo a validated sterilization process.
- Labelling: primary or secondary container must include manufacturer name/address, needle size, thread type, “Sterile injection needle for single-use”, single-use symbol, seal warning, expiry (ISO 8601), sterilization method, lot number, and quantity.
Applications and users
ISO 7885:2010 is applied by:
- Manufacturers of dental injection needles and hubs to design and validate products.
- Medical device engineers and quality teams for product specifications and compliance.
- Regulatory and procurement specialists assessing conformity and safety.
- Dental clinics and suppliers to ensure purchased needles meet safety, identification and labelling standards.
- Sterilization services and testing laboratories validating sterilization and mechanical performance.
Keywords: ISO 7885:2010, dental needles single use, sterile injection needles, dental cartridge syringes, needle dimensions, colour coding.
Related standards
Технические детали
- Технический комитет
- ISO/TC 106/SC 4 - Dental instruments
- SKU
- ISO 7885:2010
Похожие стандарты
Стандарты, упомянутые в описании
ISO 9997:1999
ОтменёнDental cartridge syringes
ISO 9626:2016
ДействующийStainless steel needle tubing for the manufacture of medical devices — Requirements and test methods
Overview ISO 9626:2016 specifies requirements and test methods for rigid stainless steel needle tubing used in the manufacture of hypodermic needles and other medical devices for human use. The secon…
ISO 6009:2016
ДействующийHypodermic needles for single use — Colour coding for identification
Overview ISO 6009:2016 - "Hypodermic needles for single use - Colour coding for identification" defines a standardized colour code to enable rapid visual identification of single‑use hypodermic needl…
ISO 8601:2004
ОтменёнData elements and interchange formats — Information interchange — Representation of dates and times
ISO 7864:2016
ДействующийSterile hypodermic needles for single use — Requirements and test methods
Overview ISO 7864:2016 - Sterile hypodermic needles for single use - Requirements and test methods sets out requirements and test methods for sterile, single‑use hypodermic needles in metric sizes 0.…
ISO 15223-1:2016
ОтменёнMedical devices — Symbols to be used with medical device labels, labelling and information to be supplied — P…
ISO 11135:2014
ДействующийSterilization of health-care products — Ethylene oxide — Requirements for the development, validation and rou…
Overview ISO 11135:2014 - Sterilization of health‑care products - Ethylene oxide specifies the requirements for the development, validation and routine control of an ethylene oxide (EO) sterilization…
ISO 11137-2:2013
ДействующийSterilization of health care products — Radiation — Part 2: Establishing the sterilization dose
Overview ISO 11137-2:2013 - “Sterilization of health care products - Radiation - Part 2: Establishing the sterilization dose” specifies validated methods to determine the minimum radiation dose requi…