ISO 7980:1986
Water quality — Determination of calcium and magnesium — Atomic absorption spectrometric method
Water quality — Determination of calcium and magnesium — Atomic absorption spectrometric method
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 3
- Дата публикации:
- 1 мая 1986 г.
- Издание:
- ISO IS 7980 edition 1 version 1
- ICS:
- 13.060.50
The procedure is intended for the analysis of raw and drinking waters and can be used for waters having a calcium content of up to 50 mg/l and a magnesium content of up to 5 mg/l. For samples containing higher concentrations of calcium or magnesium a smaller volume of the sample must be taken for the analysis.
Abstract
Overview
ISO 7980:1986 is an internationally recognized standard published by the International Organization for Standardization (ISO) that specifies a method for determining the concentration of calcium and magnesium in water. This standard employs atomic absorption spectrometry (AAS), a precise and reliable technique, to measure these essential water quality parameters. It is designed primarily for raw and drinking water analysis within specific concentration ranges-up to 50 mg/l for calcium and 5 mg/l for magnesium. For samples exceeding these concentrations, appropriate sample dilution is required.
Water quality monitoring of calcium and magnesium is crucial for assessing water hardness, potential scaling in water systems, and environmental health. ISO 7980:1986 ensures consistent, accurate results for laboratories conducting chemical analyses of water.
Key Topics
-
Scope and Application
Applicable to raw and drinking waters, this method is suitable for calcium concentrations up to 50 mg/l and magnesium concentrations up to 5 mg/l. It requires sample dilution for higher levels to maintain accuracy. -
Analytical Principle
Utilizes flame atomic absorption spectrometry (AAS) for measuring dissolved calcium and magnesium. The method adds lanthanum chloride or cesium chloride as releasing agents to minimize chemical interferences during measurement. -
Calibration and Standards
Preparation of calibration standards involves precise dilution of stock solutions for calcium and magnesium to create a series of reference concentrations. Calibration graphs are plotted by measuring absorbance at wavelengths specific to calcium (422.7 nm) and magnesium (285.2 nm). -
Reagents and Sample Preparation
Key reagents include hydrochloric acid, lanthanum chloride, and cesium chloride solutions. Samples must be acidified immediately after collection to prevent precipitation and should be filtered where particulate matter is present. -
Instrumentation
Requires an atomic absorption spectrometer capable of using air/acetylene or nitrous oxide/acetylene flame types. Choice of flame depends on sample complexity, with nitrous oxide/acetylene preferred for samples containing phosphate, sulfate, or silica. -
Quality Assurance
Includes performing blank tests, linearity checks of calibration curves, and routine verification of calibration slopes. Reported results should express concentrations in milligrams per liter or millimoles per liter, adhering to precision and recovery standards detailed in the document.
Applications
-
Water Treatment Facilities
Enables accurate monitoring of calcium and magnesium levels to assess water hardness, helping optimize chemical dosing and scaling prevention. -
Environmental Monitoring
Supports the assessment of natural water bodies and groundwater quality, informing water resource management and regulatory compliance. -
Public Health and Drinking Water Safety
Ensures water quality meets safety standards by quantifying relevant mineral content that affects taste, nutritional value, and potential health impacts. -
Industrial Water Use
Assists in monitoring water used in manufacturing processes where calcium and magnesium concentrations impact equipment maintenance and product quality.
Related Standards
ISO 7980:1986 complements other water quality standards and analytical methods, including:
- ISO 9963-1 - Determination of water hardness by complexometric titration
- ISO 11969 - Determination of soluble magnesium by atomic absorption spectrometry
- ISO 11466 - Determination of trace elements in water
- ISO 7027 - Measurement of turbidity in water (important for sample filtration)
Adherence to ISO 7980:1986 alongside related standards ensures a comprehensive approach to water quality assessment and analytical consistency across laboratories worldwide.
Keywords: ISO 7980, water quality standard, calcium determination, magnesium determination, atomic absorption spectrometry, AAS, water analysis method, water hardness testing, drinking water chemistry, water testing standard, chemical analysis of water.
Технические детали
- Технический комитет
- ISO/TC 147/SC 2 - Physical, chemical and biochemical methods
- SKU
- ISO 7980:1986
Похожие стандарты
Стандарты, упомянутые в описании
ISO 9963-1:1994
ДействующийWater quality — Determination of alkalinity — Part 1: Determination of total and composite alkalinity
Overview ISO 9963-1:1994 is an international standard specifying a reliable titrimetric method for determining total and composite alkalinity in water. Developed by the International Organization for…
ISO 11969:1996
ОтменёнWater quality — Determination of arsenic — Atomic absorption spectrometric method (hydride technique)
ISO 11466:1995
ОтменёнSoil quality — Extraction of trace elements soluble in aqua regia
ISO 7027-2:2019
ДействующийWater quality — Determination of turbidity — Part 2: Semi-quantitative methods for the assessment of transpar…
Overview ISO 7027-2:2019 - "Water quality - Determination of turbidity - Part 2" specifies semi-quantitative methods to assess water transparency (visibility) in laboratory and field settings. It com…