ISO 8316:1987
Measurement of liquid flow in closed conduits — Method by collection of the liquid in a volumetric tank
Measurement of liquid flow in closed conduits — Method by collection of the liquid in a volumetric tank
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 21
- Дата публикации:
- 24 сентября 1987 г.
- Издание:
- ISO IS 8316 edition 1 version 1
- ICS:
- 17.120.10
The specified measuring methods are built upon the determination of the volume of liquid collected in a volumetric tank in a known time interval. Deals in particular with the measuring apparatus, the procedure, the method for calculating the flow-rate and the assessment of uncertainties associated with the measurements.
Abstract
Overview
ISO 8316:1987 specifies the volumetric tank method for measuring liquid flow in closed conduits by collecting a known volume over a measured time interval. The standard covers apparatus, procedures, calculation of flow‑rate and the evaluation of measurement uncertainty. Because of its high accuracy, the volumetric method is often used as a primary calibration technique for other flow meters and for legal metrology applications.
Key topics and technical requirements
- Measurement principle
- Two main variants: static gauging (measure level before and after diversion) and dynamic gauging (measure level while filling).
- Apparatus
- Volumetric tank: typically cylindrical, leak‑proof, designed to minimise wall absorption and distortion; large enough to make timing and level errors negligible.
- Diverter: must direct flow to tank or bypass without changing flow-rate; rapid travel recommended (e.g., <0.1 s) or, for large flows, a known linear operating law. Nozzle slot pressure drop should be limited (around 20 kPa) to avoid splashing and air entrainment.
- Level measuring devices: accurate level sensing and a calibrated level–volume relationship (by transferring known volumes or dimensional calibration).
- Time measurement: accurate electronic timer (quartz) with resolution to 0.01 s or better; timer triggered by diverter motion.
- Performance and limits
- Typically used for flow-rates up to about 1.5 m3/s and commonly in laboratory/static installations.
- Expected overall uncertainty can be as low as ±0.1% to ±0.2% (95% confidence) when precautions are followed.
- Practical guidance: minimum level change ≈ 1 m and minimum filling time at maximum flow ≈ 30 s (can be reduced if verified).
- Uncertainty and corrections
- Procedures for calculating flow‑rate and assessing combined uncertainty are specified; uncertainty estimation aligns with ISO 5168.
- Annex A provides corrections for filling-time measurement effects; annexes B–E provide supporting information and examples.
Applications and users
- Calibration laboratories using volumetric methods to certify and calibrate flowmeters.
- National metrology institutes and legal metrology authorities requiring traceable, primary flow measurements.
- Industrial test facilities and R&D labs where high-accuracy liquid flow measurement is needed (meter verification, reference standards).
- Designers of volumetric flow installations and measurement engineers implementing static or dynamic gauging.
Related standards
- ISO 4006 - Vocabulary and symbols for fluid flow in closed conduits.
- ISO 4185 - Weighing method for liquid flow measurement.
- ISO 4373 - Water level measuring devices (open channels).
- ISO 5168 - Estimation of uncertainty in flow‑rate measurement.
Keywords: ISO 8316, volumetric tank, liquid flow measurement, closed conduits, flow‑rate calibration, static gauging, dynamic gauging, diverter, measurement uncertainty.
Технические детали
- Технический комитет
- ISO/TC 30 - Measurement of fluid flow in closed conduits
- SKU
- ISO 8316:1987
Похожие стандарты
Стандарты, упомянутые в описании
ISO 5168:2005
ДействующийMeasurement of fluid flow — Procedures for the evaluation of uncertainties
Overview ISO 5168:2005 - Measurement of fluid flow: Procedures for the evaluation of uncertainties provides a standardized framework for quantifying the uncertainty in measured fluid flow-rate or flo…
ISO 4006:1991
ДействующийMeasurement of fluid flow in closed conduits — Vocabulary and symbols
Overview ISO 4006:1991 - Measurement of fluid flow in closed conduits - Vocabulary and symbols - is an ISO international standard that defines recommended terms and corresponding symbols used in the…
ISO 4185:1980
ДействующийMeasurement of liquid flow in closed conduits — Weighing method
Overview ISO 4185:1980 - Measurement of liquid flow in closed conduits - Weighing method defines a primary laboratory method for measuring liquid flow by collecting and weighing the mass of liquid de…