ISO 8600-8:2021
Endoscopes — Medical endoscopes and endotherapy devices — Part 8: Particular requirements for capsule endoscopes
Endoscopes — Medical endoscopes and endotherapy devices — Part 8: Particular requirements for capsule endoscopes
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 4
- Дата публикации:
- 14 мая 2021 г.
- Издание:
- ISO IS 8600 edition 1 version 1
- ICS:
- 11.040.55
This document applies to capsule endoscopes used for clinical practice. The document defines relevant terms and gives requirements for them.
Abstract
Overview - ISO 8600-8:2021 (Capsule endoscopes)
ISO 8600-8:2021 is the ISO part that sets particular requirements for capsule endoscopes used in clinical practice. It defines key terms (maximum diameter, maximum length, recording time) and specifies product requirements, testing, marking, instruction content and packaging expectations for capsule-shaped medical endoscopes. The standard supports safe design, consistent testing and clear labeling of capsule endoscopes for manufacturers, test laboratories and healthcare providers.
Key topics and technical requirements
- Defined terms: clear definitions for maximum diameter, maximum length (measured in millimetres) and recording time used throughout design, testing and labeling.
- Physical limits: maximum diameter and maximum length shall not exceed values stated in the device instruction manual; measurements follow ISO 8600-4 methods.
- EMC / EMI: capsule endoscopes must conform to IEC 60601-1-2 for electromagnetic compatibility and immunity to electromagnetic interference.
- Field of view / direction of view: to be determined according to Method B in ISO 8600-3.
- Testing: application of ISO 8600-1 general test principles plus ISO 8600-4 for dimensional measurement (diameter and length).
- Minimum marking: each capsule must carry at least model identification/manufacturer, maximum diameter and length (mm), field/direction of view (if relevant), lot/serial number (if applicable) and expiration date.
- Instruction manual requirements: must include data transfer technology (e.g., radio transmission, body communication), modulation method and transmit/receive frequency characteristics when applicable, recording time, storage environment (temperature/humidity) and battery type and rated watt-hours.
- Packaging: follows ISO 8600-1 packaging requirements where applicable.
Practical applications - who uses ISO 8600-8:2021
- Medical device manufacturers: design, test and label capsule endoscopes to meet regulatory and market expectations.
- Regulatory bodies / Notified bodies: evaluate conformity for clinical use and market authorization, including EMC compliance.
- Test laboratories and conformity assessors: apply the referenced test methods (ISO 8600-3, ISO 8600-4, IEC 60601-1-2) to verify dimensional, optical and electromagnetic requirements.
- Hospitals and procurement teams: interpret labeling and instruction data (dimensions, field of view, recording time, battery info) to select appropriate capsule endoscopes for clinical workflows.
- Clinical engineers and biomedical technicians: ensure device compatibility with receiving units and safe storage/handling per instructions.
Related standards
- ISO 8600-1:2015 - General requirements for endoscopes
- ISO 8600-3 - Determination of field of view and direction of view (Method B referenced)
- ISO 8600-4 - Determination of maximum width/length of insertion portion (dimensional measurement)
- ISO 8600-6 - Vocabulary for endoscopes
- IEC 60601-1-2 - Medical electrical equipment - EMC requirements
Keywords: ISO 8600-8:2021, capsule endoscopes, medical endoscopes, EMC, field of view, maximum diameter, recording time, device marking, instruction manual.
Технические детали
- Технический комитет
- ISO/TC 172/SC 5 - Microscopes and endoscopes
- SKU
- ISO 8600-8:2021
Похожие стандарты
Стандарты, упомянутые в описании
ISO 8600-1:2015
ОтменёнEndoscopes — Medical endoscopes and endotherapy devices — Part 1: General requirements
Overview ISO 8600-1:2015 - "Endoscopes - Medical endoscopes and endotherapy devices - Part 1: General requirements" provides core definitions and general requirements for the design, construction, te…
ISO 8600-4:2023
ДействующийEndoscopes — Medical endoscopes and endotherapy devices — Part 4: Determination of maximum width of insertion…
Overview ISO 8600-4:2023 is an international standard developed by ISO that defines a precise method for measuring the maximum width of the insertion portion of medical endoscopes and certain endosco…
IEC 60601-1-2:2014
ДействующийMedical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Co…
Overview IEC 60601-1-2:2014, published by the International Electrotechnical Commission (IEC), defines the requirements and tests relating to the basic safety and essential performance of medical ele…
ISO 8600-3:2019
ДействующийEndoscopes — Medical endoscopes and endotherapy devices — Part 3: Determination of field of view and directio…
Overview ISO 8600-3:2019 - "Endoscopes - Medical endoscopes and endotherapy devices - Part 3" defines standardized measurement methods for the field of view (FOV) and direction of view of medical end…
ISO 8600-1:2025
ДействующийEndoscopes — Medical endoscopes and endotherapy devices — Part 1: General requirements
Overview ISO 8600-1:2025 - "Endoscopes - Medical endoscopes and endotherapy devices - Part 1: General requirements" is the fifth edition of the international standard that defines core terminology an…