ISO 9187-1:2010
Injection equipment for medical use — Part 1: Ampoules for injectables
Injection equipment for medical use — Part 1: Ampoules for injectables
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 9
- Дата публикации:
- 30 сентября 2010 г.
- Издание:
- ISO IS 9187 edition 4 version 1
- ICS:
- 11.040.20
ISO 9187-1:2010 specifies materials, dimensions, capacities, performance and packaging requirements for three forms of glass ampoule (forms B, C and D) for injectable pharmaceutical products. ISO 9187-1:2010 is applicable to ampoules with and without a colour break-ring; the provision of ampoules with a colour break-ring, and the choice of colour of the break-ring, is subject to agreement between the manufacturer and user. Ampoules complying with ISO 9187-1:2010 are intended for single use only.
Abstract
Overview
ISO 9187-1:2010 - "Injection equipment for medical use - Part 1: Ampoules for injectables" specifies requirements for glass ampoules used as primary packaging for injectable pharmaceutical products. The standard covers three standardized ampoule forms (B, C and D), applicable nominal volumes (1–30 ml series), material selection, dimensional tolerances, performance tests and packaging/marking rules. ISO 9187-1:2010 applies to ampoules with or without a colour break‑ring (colour selection by agreement) and defines ampoules as intended for single use only.
Keywords: ISO 9187-1:2010, ampoules for injectables, glass ampoule standards, pharmaceutical packaging standards
Key Topics and Requirements
- Ampoule forms and dimensions: Detailed dimensional tables for forms B, C and D and nominal volumes (1, 2, 3, 5, 10, 20, 25, 30 ml) including body, constriction, stem, funnel and overall heights.
- Material: Colourless (cl) or amber (br) glass of hydrolytic resistance grain class HGA 1 (per ISO 720).
- Hydrolytic resistance: Internal surface must meet container class HC 1 and T HC 1 when tested per ISO 4802‑1 and ISO 4802‑2 to avoid drug–container interactions.
- Annealing quality: Maximum residual stress for uncoloured ampoules limited to optical retardation ≤ 50 nm/mm of glass thickness.
- Breaking force: Defined breaking force ranges and a tensile test procedure (example setup, test speed 10 mm/min, machine verification per ISO 7500‑1, measuring range ~200 N) to ensure predictable, clean stem separation.
- Sampling & testing: Sampling guidance (ISO 2859‑1 recommended, inspection level S‑4) and conditioning (20 °C ± 5 °C) before tests.
- Packaging & marking: Packaging unit dimensions, particle‑minimizing materials, and mandatory marking (manufacturer name/address and ISO designation).
Applications and Who Uses the Standard
- Ampoule manufacturers: design, production tolerances, material selection, QC testing and supplier documentation.
- Pharmaceutical companies: primary packaging selection for liquid injectables, stability and compatibility assessment.
- Regulatory and quality assurance: compliance checks, incoming inspection, lot acceptance and audit criteria.
- Laboratories and test houses: performing hydrolytic resistance, breaking force and annealing quality tests.
- Procurement and supply chain: specifying ampoule form, volume, glass colour and break‑ring options in contracts.
Keywords: pharmaceutical packaging, ampoule dimensions, hydrolytic resistance testing, breaking force testing
Related Standards
- ISO 720 - Glass: hydrolytic resistance classification
- ISO 4802‑1, ISO 4802‑2 - Hydrolytic resistance test methods for glass containers
- ISO 7500‑1 - Verification of tensile/compression testing machines
- ISO 2859‑1 - Sampling procedures for inspection by attributes
- ISO 1101 - Geometrical tolerancing (referenced for run‑out)
This concise guide helps manufacturers, QA/QC and pharmaceutical users understand the scope and practical requirements of ISO 9187-1:2010 for safe, compliant glass ampoules for injectables.
Технические детали
- Технический комитет
- ISO/TC 76 - Transfusion, infusion and injection, and blood processing equipment for medical and pharmaceutical use
- SKU
- ISO 9187-1:2010
Похожие стандарты
Стандарты, упомянутые в описании
ISO 7206-1:1995
ОтменёнImplants for surgery — Partial and total hip joint prostheses — Part 1: Classification and designation of dim…
ISO 4802-1:2023
ДействующийGlassware — Hydrolytic resistance of the interior surfaces of glass containers — Part 1: Determination by tit…
Overview ISO 4802-1:2023 - Glassware - Hydrolytic resistance of the interior surfaces of glass containers - Part 1: Determination by titration method and classification defines a standardized laborat…
ISO 4802-2:2016
ОтменёнGlassware — Hydrolytic resistance of the interior surfaces of glass containers — Part 2: Determination by fla…
ISO 7500-1:2018
ДействующийMetallic materials — Calibration and verification of static uniaxial testing machines — Part 1: Tension/compr…
Overview ISO 7500-1:2018 - "Metallic materials - Calibration and verification of static uniaxial testing machines - Part 1: Tension/compression testing machines - Calibration and verification of the…