SIST EN ISO 24966:2026
Determination of flash point - Modified continuously closed cup flash point (MCCCFP) method (ISO 24966:2026)
Determination of flash point - Modified continuously closed cup flash point (MCCCFP) method (ISO 24966:2026)
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 24
- Дата публикации:
- 5 мая 2026 г.
- Издание:
- 0002330006748
- ICS:
- 75.100
This document describes a test method for the determination of the flash point of chemicals, lube oils, fuels including aviation turbine fuel, diesel fuel, diesel/biodiesel blends and related products. The precision of this method has been determined over the range of 24,5 °C to 229,5 °C. NOTE Apparatus can determine the flash point at higher or lower temperatures than the precision range, however the precision has not been determined.
Abstract
Overview
SIST EN ISO 24966:2026 defines a standardized test method for the determination of flash point in chemicals, lube oils, fuels, including aviation turbine fuel, diesel fuel, diesel/biodiesel blends, and related petroleum products. Utilizing the Modified Continuously Closed Cup Flash Point (MCCCFP) method, this standard is essential for accurate and repeatable measurement of flash points in a wide variety of liquid fuels and lubricants. The method is validated for samples with flash points ranging from 24.5 °C to 229.5 °C, with detailed guidance on apparatus, procedures, precision, and test reporting.
Key Topics
- Flash Point Determination: Outlines a uniform procedure using a modified continuously closed cup apparatus, ensuring safety and comparability of results.
- Precision and Reliability: Includes precision data based on inter-laboratory studies, with specific repeatability and reproducibility values in the stated temperature range.
- Sample Handling: Provides detailed instructions for sample collection, handling, sub-sampling, and storage to minimize volatility losses and contamination.
- Safety Considerations: Emphasizes that users must conduct risks assessments, especially when handling hazardous, unstable, or flammable materials.
- Apparatus Verification: Requires periodic verification and calibration of equipment using certified reference materials, ensuring accuracy and compliance.
- Data Correction and Expression: Explains procedures for correcting flash point readings for atmospheric pressure and accurate reporting.
Applications
SIST EN ISO 24966:2026 is a vital reference across industries where the flash point of liquids governs transportation, storage, classification, and safety compliance. Typical applications include:
- Quality control for fuels and lubricants by manufacturers, refiners, and suppliers.
- Regulatory compliance for shipping and labeling of chemicals and fuels, aligning with national and international safety regulations.
- Research and development in product formulation, ensuring new products meet minimum flash point requirements for their intended use.
- Customs and border control for classifying dangerous goods.
- Environmental and safety assessments to prevent fire or explosion hazards in storage and transport.
- Verification and proficiency testing in laboratories accredited for testing petroleum products and fuels.
Adhering to this standard supports the consistent assessment of flammability characteristics, which is crucial for hazard communication and operational safety.
Related Standards
- ISO 3170: Petroleum liquids - Manual sampling (covers representative sampling protocols)
- ISO 3171: Petroleum liquids - Automatic pipeline sampling (for automated sample collection)
- ISO/TR 29662: Guidance for performing flash point tests and interpreting results
- ISO 17034 & ISO Guide 35: Quality standards for certified reference materials, supporting apparatus calibration
- ISO 4259-3: Procedures for establishing and using accepted reference values in test methods
- ISO 17043: Proficiency testing requirements, relevant for laboratory verification
- ICS Codes: 75.100 (Lubricants, industrial oils, and related products), 75.160.20 (Liquid fuels), 75.160.40 (Fuels from biological sources)
Practical Value
Implementing SIST EN ISO 24966:2026 ensures repeatable, accurate flash point determination in quality assurance, regulatory compliance, and R&D across the fuel, chemical, and lubricants industries. The adoption of the MCCCFP method under this ISO standard strengthens fire safety, hazard classification, and efficient international trade by harmonizing the measurement of a key property - the flash point - for a wide range of products.
Efficient use of this standard supports improved safety protocols, product consistency, and alignment with global trade and transport regulations for hazardous liquids.
Технические детали
- Технический комитет
- NAD - Petroleum products, lubricants and related products
- SKU
- SIST EN ISO 24966:2026
Похожие стандарты
Стандарты, упомянутые в описании
ISO 24966:2026
ДействующийDetermination of flash point — Modified continuously closed cup flash point (MCCCFP) method
Overview ISO 24966:2026 - Determination of Flash Point - Modified Continuously Closed Cup Flash Point (MCCCFP) Method provides a standardized procedure for measuring the flash point of chemicals, lub…
BS EN ISO 3170:2025
ДействующийHydrocarbon Liquids. Manual sampling.
BS EN ISO 3171:1999
ДействующийMethods of test for petroleum and its products. BS 2000-476: Petroleum liquids. Automatic pipeline sampling.
ISO/TR 29662:2020
ДействующийPetroleum products and other liquids — Guidance for flash point and combustibility testing
Overview - ISO/TR 29662:2020 (Flash point and combustibility testing) ISO/TR 29662:2020 is a Technical Report from ISO providing guidance on flash point testing and combustibility testing for petrole…