IEC 61753-1:2018
Fibre optic interconnecting devices and passive components - Performance standard - Part 1: General and guidance
Fibre optic interconnecting devices and passive components - Performance standard - Part 1: General and guidance
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 118
- Дата публикации:
- 24 июня 2020 г.
- Издание:
- IEC IS 61753 edition 2 version 1
- ICS:
- 33.180.20
IEC 61753-1:2018 provides guidance for the drafting of performance standards for all passive fibre optic products. This document defines the tests and severities which form the performance categories or general operating service environments and identifies those tests which are considered to be product specific. Test and severity details are given in Annex A. This second edition cancels and replaces the first edition published in 2007. It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) definitions updated with new products: wall outlets, wall or pole mounted boxes, splices, ODF modules, street cabinets, hardened connectors and field mountable connectors; b) categories U and O are replaced by categories OP and OP+. No mandatory sequence in category OP+. Category OP+ contains the tests from category OP with the addition of only 4 other tests; c) addition of Category I (Industrial); d) temperature ranges added (with the HD suffix to the categories C, OP, OP+ and I) in case passive optical components are placed in a housing together with active electronics (HD stands for “heat dissipation”); e) the height of category A changed from 3 m to ground level (0 m); f) the lower level height of category G environment changed from ground level (0 m) to –1 m below ground level. Upper level remains at 3 m above ground level; g) addition of performance tests, test severities and performance criteria for new products: Wall outlet, wall or pole mounted boxes, mechanical splices, fusion splice protectors, ODF modules, street cabinets, field mountable connectors and hardened optical connectors; h) test severity of "Mating durability" test for connectors in categories C, OP ,OP+ and I is reduced to 200 cycles for connectors with cylindrical ferrules and 50 cycles for connectors with rectangular ferrules; i) test severity of "Change of temperature" test for connectors and passive optical components in category I is reduced from 20 cycles to 12 cycles (harmonized with connectors and components from other categories); j) test severity of "Flexing of strain relief" test for connectors in categories C, OP and OP+ is reduced to 50 cycles; k) test severities of "Assembly and disassembly of fibre optic mechanical splices, fibre management systems and closures" test for all enclosures is reduced to 5 cycles; l) test severities of "Change of temperature" test for all protective housings in categories C, A, G and S is reduced from 20 cycles to 12 cycles (harmonized with connectors and components); m) test severities of "Resistance to solvents and contaminating fluids" test for closures in categories G and S changed – kerosene is removed, diesel oil exposure reduced to 1 h immersion and 24 h drying at room temperature; n) sealing performance criteria of sealed closures for categories G and A are reduced to 20 kPa overpressure. o) the change in attenuation criterion for connectors has changed from peak-to-peak into a +/- deviation from the original value of the transmitted power at the start of the test (harmonized with the change in attenuation criterion for components, splices and protective housings). Keywords: performance standards for all passive fibre optic products The contents of the corrigendum of May 2019 have been included in this copy.
Abstract
Overview
IEC 61753-1:2018 - Fibre optic interconnecting devices and passive components - Part 1: General and guidance - defines how to draft performance standards for all passive fibre optic products. This second edition (2018, corrigendum May 2019 included) replaces the 2007 edition and provides guidance on selecting tests, severities and pass/fail criteria that establish performance categories and general operating service environments. Annex A contains the normative list of tests, severities and performance criteria.
Key topics and technical requirements
- Performance categories and operating environments: Defines categories such as C (controlled), OP / OP+ (outdoor protected / extended outdoor protected), I (industrial), A (aerial), G (ground), S (subterranean) and E (extreme). An HD suffix covers components placed in housings with active electronics (heat dissipation).
- Tests and severities: Normative test definitions and severity levels are provided in Annex A. Tests include environmental, mechanical and performance verifications (examples from the standard):
- Mating durability: reduced to 200 cycles for cylindrical-ferrule connectors and 50 cycles for rectangular-ferrule connectors.
- Change of temperature: harmonized reductions to 12 cycles for many categories (including category I and many housings).
- Flexing of strain relief: reduced to 50 cycles for connectors in categories C, OP and OP+.
- Assembly/disassembly for enclosures: severity reduced to 5 cycles.
- Resistance to solvents/contaminating fluids: amended exposures (kerosene removed; diesel oil immersion reduced).
- Sealing performance: sealed closures in categories G and A require 20 kPa overpressure.
- Attenuation criterion: changed from peak-to-peak to a ± deviation relative to original transmitted power (harmonized across components, splices and housings).
- Product scope updates: New or clarified definitions for wall outlets, boxes, splices, ODF modules, street cabinets, hardened and field-mountable connectors, fusion splice protectors and mechanical splices.
- Test sequencing and reporting: Guidance on grouping/sequencing tests, sample definitions, pass/fail criteria and performance standard test reports.
Practical applications and users
IEC 61753-1 is essential for:
- Manufacturers of passive fibre optic products (connectors, closures, ODF modules, splices, cabinets) to develop product performance standards and test plans.
- Test laboratories and QA teams performing environmental and mechanical qualification testing.
- Systems integrators, network designers and procurement specialists who need to specify performance categories and verify compliance for indoor, outdoor, industrial or harsh-environment deployments.
- Certification bodies and standards committees aligning product requirements and interoperability.
Related standards
- Refer to other parts of the IEC 61753 series and related IEC standards on fibre optic connectors and components for product-specific test methods and dimensional/optical specifications.
Keywords: performance standards for all passive fibre optic products, fibre optic interconnecting devices and passive components, IEC 61753-1, performance categories, tests and severities, passive fibre optic products.
Технические детали
- Технический комитет
- SC 86B - Fibre optic interconnecting devices and passive components
- SKU
- IEC 61753-1:2018
Похожие стандарты
Упомянутые в описании и другие стандарты IEC
IEC 61753-111-08:2021
ДействующийFibre optic interconnecting devices and passive components - Performance standard - Part 111-08: Sealed closu…
Overview - IEC 61753-111-08:2021 (Sealed closures for category G – Ground) IEC 61753-111-08:2021 is an IEC performance standard that specifies the minimum tests, test severities and measurement requi…
IEC 61753-042-02:2026
ДействующийFibre optic interconnecting devices and passive components - Performance standard - Part 042-02: Plug-pigtail…
Overview IEC 61753-042-02:2026 establishes the minimum performance, test, and measurement requirements for plug-pigtail and plug-receptacle style OTDR (Optical Time-Domain Reflectometer) reflecting d…
IEC 62590-2-2:2026
ДействующийRailway applications - Electronic power converters for fixed installations - Part 2-2: DC Traction applicatio…
Overview IEC 62590-2-2:2026 is an international standard developed by the International Electrotechnical Commission (IEC) focusing on railway applications, specifically the electronic power converter…
IEC 61837-2:2018
ДействующийSurface mounted piezoelectric devices for frequency control and selection - Standard outlines and terminal le…
Overview IEC 61837-2:2018 - Surface mounted piezoelectric devices for frequency control and selection - Standard outlines and terminal lead connections - Part 2: Ceramic enclosures (Edition 3.0, 2018…
IEC 61851-23-1:2026
ДействующийElectric vehicle conductive charging system - Part 23-1: DC electric vehicle supply equipment - Automated con…
Overview IEC 61851-23-1:2026 is an international standard published by the International Electrotechnical Commission (IEC) that specifies requirements for DC electric vehicle supply equipment (EVSE)…
IEC 63506:2026
ДействующийCalibration of the prompt fission neutron logging tools
Overview IEC 63506:2026 - Calibration of the Prompt Fission Neutron Logging Tools is the international standard that specifies the calibration methods for prompt fission neutron (PFN) logging tools,…
IEC 63589-1:2026
ДействующийLinear accelerator - Electron linear accelerator for radiation processing - Part 1: General requirements and…
Overview IEC 63589-1:2026 specifies the general requirements and test methods for electron linear accelerator devices used in radiation processing. Developed by the International Electrotechnical Com…
IEC 61837-2:2018/AMD2:2026
ДействующийAmendment 2 - Surface mounted piezoelectric devices for frequency control and selection - Standard outlines a…
Overview IEC 61837-2:2018/AMD2:2026, published by the International Electrotechnical Commission (IEC), serves as Amendment 2 to the international standard for surface mounted piezoelectric devices us…