ISO 10295-2:2009
Fire tests for building elements and components — Fire testing of service installations — Part 2: Linear joint (gap) seals
Fire tests for building elements and components — Fire testing of service installations — Part 2: Linear joint (gap) seals
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 24
- Дата публикации:
- 19 января 2009 г.
- Издание:
- ISO IS 10295 edition 1 version 1
- ICS:
- 13.220.50
ISO 10295-2:2009 specifies the heating conditions, methods of test and criteria for the evaluation of the ability of a linear joint seal to maintain the fire integrity and thermal insulation of a fire-separating element at the joint being sealed. The purpose of the tests is to assess the integrity and insulation performance of the linear joint seals, including the effects of induced movement in those cases where the joint is designed to accommodate movement and has a width greater than 20 mm. It is not the intention of this part of ISO 10295-2:2009 to provide quantitative information on the rate of leakage of smoke and/or gases, or on the transmission or generation of fumes, although such phenomena can be recorded in describing the general behaviour of specimens during the test. It is not the intention of this part of ISO 10295-2:2009 to evaluate joint seals where special test procedures already exist, e.g. doors, partitions, penetrations, pipes, ducts and cables.
Abstract
Overview
ISO 10295-2:2009 - Fire tests for building elements and components: Fire testing of service installations - Part 2: Linear joint (gap) seals - specifies test heating conditions, procedures and acceptance criteria to evaluate the fire integrity and thermal insulation performance of linear joint seals installed in fire-separating elements (walls, floors, ceilings). The standard is intended to assess seal performance under standard fire exposure (ISO 834-1) including the effects of induced movement for joints designed to accommodate movement. It does not quantify smoke/gas leakage rates or cover items covered by other dedicated tests (doors, ducts, pipes, cables).
Key topics and technical requirements
- Scope and purpose: Tests evaluate the ability of a linear joint seal to maintain fire integrity and insulation at the joint being sealed; movement accommodation is included for seals wider than 20 mm.
- Test heating: Uses the standard fire curve defined in ISO 834-1.
- Specimen and test construction: Supporting construction must be representative of practice and of known fire resistance. Minimum specimen length and dimensions: at least 1 m for seals ≤100 mm; maintain a 10:1 length-to-width ratio for wider seals; seals >300 mm have minimum lengths of 3 m (vertical) and 4 m (horizontal).
- Pressure and furnace: Vertical and horizontal furnace pressure requirements include a minimum positive pressure of 20 Pa at specified locations to ensure realistic exposure. Minimum furnace clearances and internal sizes are defined to avoid direct flame impingement.
- Movement cycling: For joints >20 mm designed for movement, specimens are cycled prior to testing using specified apparatus to simulate service movement.
- Splices, blockouts and orientation: Splice locations and blockouts are controlled (splices must be within the positive-pressure zone and maintain minimum distances from furnace faces and other splices). Tests may be run in both vertical and horizontal orientations where applicable.
- Instrumentation & acceptance: Temperature and deflection instrumentation and criteria for integrity and insulation are specified; test reports must include construction details, test data and observed behaviour.
Practical applications
- Product development and fire performance certification of joint seal systems used at construction joints, floor perimeters and movement joints.
- Type testing by independent laboratories to support manufacturer declarations and regulatory approvals.
- Selection and specification of joint seals by fire safety engineers, architects, contractors and procurement teams to meet building code and fire safety requirements.
- Forensic assessment and performance comparison of alternative seal materials or installation methods.
Who should use this standard
- Joint seal manufacturers and R&D teams
- Accredited fire test laboratories and certification bodies
- Fire safety engineers, architects, specifiers and code compliance officers
- Construction product assessors and building regulators
Related standards
- ISO 834-1 (fire-resistance test heating) - normative reference
- ISO 10295-1 (Part 1: Penetration seals)
- ISO 13943 (fire safety vocabulary)
Keywords: ISO 10295-2:2009, linear joint seals, fire testing, fire resistance, joint seal testing, ISO 834-1, movement cycling, fire-separating element.
Технические детали
- Технический комитет
- ISO/TC 92/SC 2 - Fire containment
- SKU
- ISO 10295-2:2009
Похожие стандарты
Стандарты, упомянутые в описании
ISO 834-10:2014
ДействующийFire resistance tests — Elements of building construction — Part 10: Specific requirements to determine the c…
Overview ISO 834-10:2014 - Fire resistance tests - Elements of building construction - Part 10 - specifies test methods to determine the contribution of applied fire protection materials to structura…
ISO 10295-1:2007
ОтменёнFire tests for building elements and components — Fire testing of service installations — Part 1: Penetration…
Overview ISO 10295-1:2007 - Fire tests for building elements and components: Fire testing of service installations - Part 1: Penetration seals specifies a standardized furnace test method to evaluate…