Overview
ISO 5222-3:2026 specifies standardized methods for testing and calculating the annual sensible heating and cooling recovery performance factors of heat recovery ventilators (HRVs). Developed by the International Organization for Standardization (ISO), this document is part of a broader series that establishes a unified approach for assessing the seasonal energy efficiency of HRVs, ensuring consistency in product marking and facilitating performance comparison. The standard covers HRVs as defined in ISO 16494-1 and describes the necessary test conditions and procedures to determine the annual sensible heating and cooling recovery seasonal performance factors under various temperature conditions.
Key Topics
-
Testing Methodology:
- Specifies standardized test conditions and procedures for HRVs.
- Outlines requirements for equipment accuracy and measurement uncertainty as referenced in related ISO standards (ISO 16494-1, ISO 5222-1, ISO 5222-2).
- Defines test conditions using standardized temperature bins to represent varying climate zones.
-
Calculation Methods:
- Details the calculation of the annual sensible heating and cooling recovery performance factor (Fa).
- Includes methods for determining recovery capacity and power input for both heating and cooling seasons.
- Describes how to apply default or specific temperature bin distributions to reflect different regional climates.
-
Performance Factors:
- Provides formulas for calculating:
- Sensible heating and cooling recovery capacities.
- Annual performance factor based on recovered energy relative to energy input.
- Explains how to adapt calculation procedures to suit particular applications or climatic conditions.
-
Reporting Requirements:
- Establishes minimum data to be included in test reports, such as descriptions, references, test results, and key metrics for HRVs.
Applications
Related Standards
ISO 5222-3:2026 is part of a suite of standards related to heat recovery ventilators and energy recovery ventilators:
-
ISO 16494-1:2022
Method of test for performance - fundamental metrics for evaluating energy-related performance of HRVs and ERVs.
-
ISO 5222-1:2025
Testing and calculating methods for seasonal performance factor - focuses on sensible heating recovery seasonal performance factors of HRVs.
-
ISO 5222-2:2025
Testing and calculating methods for seasonal performance factor - details sensible cooling recovery seasonal performance factors of HRVs.
Implementing ISO 5222-3:2026 supports organizations in improving building air quality and energy management through robust, globally recognized testing and calculation methods for HRV annual performance.
Keywords:
ISO 5222-3, heat recovery ventilators, energy recovery ventilators, annual performance factor, sensible heating recovery, sensible cooling recovery, HRV testing, energy efficiency, ISO standards, HVAC performance.