ISO/IEC 14763-3:2014
Information technology - Implementation and operation of customer premises cabling - Part 3: Testing of optical fibre cabling
Information technology - Implementation and operation of customer premises cabling - Part 3: Testing of optical fibre cabling
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 51
- Дата публикации:
- 4 июня 2014 г.
- Издание:
- IEC IS 14763 edition 2 version 1
- ICS:
- 35.200
ISO/IEC 14763-3:2014(E) specifies systems and methods for the inspection and testing of installed optical fibre cabling designed in accordance with premises cabling standards including ISO/IEC 11801, ISO/IEC 24764, ISO/IEC 24702 and ISO/IEC 15018. The test methods refer to existing standards-based procedures where they exist. This second edition cancels and replaces the first edition published in 2006 and its Amendment 1:2009. It constitutes a technical revision. This edition includes the following changes: - general requirements have been revised; - OTDR characterization (6.2) and requirements for cabling interface adapters and test cords have been revised; - enhanced three-test-cord reference method has been introduced; - information on optical time domain reflectometry (Annex C) has been revised; - examples of calculations of channel and permanent link limits (Annex G) have been revised and information regarding cleaning and inspection of fibre optic connections have been added (Annex H). The contents of the corrigendum of March 2015 have been included in this copy.
Abstract
Overview
ISO/IEC 14763-3:2014 - Information technology - Implementation and operation of customer premises cabling - Part 3: Testing of optical fibre cabling - specifies standardized systems and methods for the inspection and testing of installed optical fibre cabling in premises networks. It covers test procedures for both single‑mode and multimode fibre, references existing standards-based procedures where available, and updates the 2006 edition with revised general requirements, OTDR characterization, test cord requirements, an enhanced three‑test‑cord reference method, and added guidance on cleaning and inspection of fibre optic connections.
Key topics & technical requirements
- Test methods: Formal procedures for LSPM (light source and power meter) and OTDR (optical time domain reflectometry) measurements for attenuation, length and propagation delay.
- Test equipment: Requirements for light sources, power meters, OTDRs, inspection microscopes, test cords and adapters; emphasis on calibration, reference measurements and test system stability.
- Reference methods: Introduction of an enhanced three‑test‑cord reference method (and a one‑test‑cord method) for accurate channel and permanent link attenuation measurement.
- OTDR characterization: Procedures for OTDR launch and tail test cords, effective characterization, dynamic range, pulse width and limitations (dead zones, ghosting).
- Connector and cabling inspection: Visual inspection criteria for end faces, cleaning and inspection guidance (Annex H) and requirements for connector return loss testing (referencing IEC 61300‑3‑6 method 2).
- Quality, documentation and uncertainty: Requirements for environmental conditions, treatment of marginal results, measurement uncertainty, and documentation and reporting of test results.
- Annexes: Informative/demo materials including OTDR guidance (Annex C), examples of channel/permanent link calculations (Annex G), and test cord inspection/testing (Annex D).
Practical applications & who uses it
ISO/IEC 14763-3:2014 is used by:
- Cabling installers and technicians performing installation verification and certification of premises cabling.
- Test labs and certification bodies for formal acceptance testing of optical fibre channels and permanent links.
- Network designers and facilities managers to specify test requirements within site acceptance criteria.
- Quality managers to build inspection and test schedules that align with premises cabling standards. Practical use cases include certifying building backbone and horizontal fibre links, troubleshooting optical faults with OTDR, measuring connector loss and return loss, and ensuring clean end‑faces before certification.
Related standards
- ISO/IEC 11801 (generic cabling)
- ISO/IEC 24764, ISO/IEC 24702, ISO/IEC 15018 (specialized premises cabling)
- IEC 61300 series (connector and fibre test methods, e.g., return loss)
Keywords: ISO/IEC 14763-3:2014, testing of optical fibre cabling, OTDR testing, LSPM, launch test cord, attenuation measurement, return loss, fibre end-face inspection, premises cabling certification.
Технические детали
- Технический комитет
- ISO/IEC JTC 1/SC 25 - Interconnection of information technology equipment
- SKU
- ISO/IEC 14763-3:2014
Похожие стандарты
Стандарты, упомянутые в описании
IEC 61300-3-6:2008
ДействующийFibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-6…
Overview IEC 61300-3-6:2008 is an internationally recognized standard published by the International Electrotechnical Commission (IEC) that defines the basic test and measurement procedures for asses…
ISO/IEC 11801-6:2017
ДействующийInformation technology — Generic cabling for customer premises — Part 6: Distributed building services
Overview ISO/IEC 11801-6:2017 - "Information technology - Generic cabling for customer premises - Part 6: Distributed building services" specifies generic cabling for premises that comprise single or…
ISO/IEC 24764:2010
ОтменёнInformation technology — Generic cabling systems for data centres
ISO/IEC 24702:2006
ОтменёнInformation technology — Generic cabling — Industrial premises
ISO/IEC 15018:2004
ОтменёнInformation technology — Generic cabling for homes
IEC 61300-2-33:2026
ДействующийFibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-3…
Overview IEC 61300-2-33:2026 is an international standard developed by the International Electrotechnical Commission (IEC). It specifies basic test and measurement procedures for fibre optic intercon…