ISO/IEC 29341-6-14:2008
Information technology - UPnP Device Architecture - Part 6-14: Heating, Ventilation, and Air Conditioning Device Control Protocol - Setpoint Schedule Service
Information technology - UPnP Device Architecture - Part 6-14: Heating, Ventilation, and Air Conditioning Device Control Protocol - Setpoint Schedule Service
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 14
- Дата публикации:
- 28 ноября 2008 г.
- Издание:
- ISO IS 29341 edition 1 version 1
- ICS:
- 35.200
Ingrid Glavich Ingrid Glavich 2 4 1995-11-10T13:27:00Z 2008-11-17T15:04:00Z 2008-11-17T15:04:00Z 1 79 451 3 1 529 10.6845 Clean 21 0 0 MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman";} ISO/IEC 29341-6-14:2008(E) provides a description of variables for which timed setpoints are established, such as day of week, event name and heating or cooling setpoint. The series of ISO/IEC 29341 publications defines an architecture for pervasive peer-to-peer network connectivity of intelligent appliances, wireless devices and PCs. It is designed to bring easy to use, flexible, standards-based connectivity to ad-hoc or unmanaged networks whether in the home, in a small business, public spaces or attached to the Internet.
Abstract
ISO/IEC 29341-6-14:2008 Overview
ISO/IEC 29341-6-14:2008, titled Information technology - UPnP Device Architecture - Part 6-14: Heating, Ventilation, and Air Conditioning Device Control Protocol - Setpoint Schedule Service, is an international standard developed by the International Electrotechnical Commission (IEC). It defines a service protocol within the Universal Plug and Play (UPnP) Device Architecture tailored specifically for HVAC (Heating, Ventilation, and Air Conditioning) setpoint schedules.
This standard facilitates communication and control of HVAC systems by describing variables and actions related to timed temperature setpoints, thus enabling flexible, standards-based connectivity and interoperability of intelligent HVAC appliances within homes, offices, and public spaces. It is particularly suited for ad-hoc and unmanaged network environments, supporting pervasive peer-to-peer networked devices.
Key Topics and Features
-
Setpoint Schedule Variables The standard defines key state variables to manage HVAC schedules, including:
- Day of Week (A_ARG_TYPE_DayOfWeek): Specifies the day associated with scheduled events.
- Event Name (A_ARG_TYPE_EventName): Identifies named events for which schedules apply, such as "morning warmup".
- Start Time (A_ARG_TYPE_StartTime): Indicates when a scheduled temperature change begins.
- Heating Setpoint (A_ARG_TYPE_HeatingSetpoint): Temperature setting for heating during an event.
- Cooling Setpoint (A_ARG_TYPE_CoolingSetpoint): Temperature setting for cooling.
- EventsPerDay: A delimited string outlining all scheduled setpoint changes for a specific day.
-
Core Actions The protocol defines key control interactions to manage setpoint schedules:
- SetEventParameters: Create or update scheduled events with relevant parameters (time, setpoints, event name).
- GetEventsPerDay: Retrieve a list of scheduled temperature setpoint events for a specified day.
-
Service Compliance and Identification Utilizes the UPnP Service Type identifier:
URN:SCHEMAS-UPNP-ORG:SERVICE:HVAC_SETPOINTSCHEDULE:1 -
Eventing and Moderation Supports event notifications to subscribe clients when setpoint schedules change, enabling responsive HVAC control systems.
Practical Applications
ISO/IEC 29341-6-14:2008 serves as a foundation for smart HVAC systems in residential, commercial, and public environments. Key applications include:
-
Smart Home Automation: Enables programmable HVAC temperature settings based on daily routines, improving energy efficiency and occupant comfort.
-
Commercial Building Management: Facilitates centralized control of HVAC schedules across multiple zones or rooms, optimizing resource use and maintenance.
-
IoT HVAC Devices: Supports seamless integration of HVAC thermostats and sensors into IoT ecosystems allowing peer-to-peer communication without centralized control.
-
Public Spaces and Small Businesses: Allows flexible HVAC scheduling that adapts to opening hours and occupancy patterns to reduce operational costs.
Related Standards and Series
ISO/IEC 29341-6-14:2008 belongs to the broader ISO/IEC 29341 series, which standardizes UPnP device architectures and services. Related parts pertinent to HVAC and device control include:
- ISO/IEC 29341-6-1: UPnP HVAC System Device
- ISO/IEC 29341-6-2: UPnP HVAC Zone Thermostat Device
- ISO/IEC 29341-6-10: UPnP Control Valve Service
- ISO/IEC 29341-6-11: UPnP HVAC Fan Operating Mode Service
- ISO/IEC 29341-6-12: UPnP Fan Speed Service
- ISO/IEC 29341-6-13: UPnP House Status Service
- ISO/IEC 29341-6-15: UPnP Temperature Sensor Service
- ISO/IEC 29341-6-16: UPnP Temperature Setpoint Service
- ISO/IEC 29341-6-17: UPnP HVAC User Operating Mode Service
This interconnected suite enables comprehensive UPnP-based control and monitoring of complex HVAC systems.
Why Adopt This Standard?
Implementing ISO/IEC 29341-6-14:2008 in HVAC device design or building automation solutions provides several advantages:
- Interoperability: Ensures compatibility across different vendors and devices in a UPnP network.
- Energy Efficiency: Supports precise scheduling of heating and cooling setpoints to align with occupancy and usage patterns.
- Simplified Integration: Facilitates plug-and-play networking with PCs, intelligent appliances, and wireless devices without complex setup.
- Scalability: Designed for various network scales from single residences to large business environments.
For manufacturers, service providers, and system integrators targeting intelligent HVAC solutions, adherence to this standard guarantees alignment with internationally recognized protocols enhancing market reach and customer satisfaction.
Keywords: ISO/IEC 29341-6-14:2008, UPnP Device Architecture, HVAC Device Control, Setpoint Schedule Service, Heating Ventilation Air Conditioning, Smart HVAC Standards, HVAC Scheduling Protocol, UPnP HVAC Integration, Intelligent HVAC Systems, Building Automation Standards
Технические детали
- Технический комитет
- ISO/IEC JTC 1 - Information technology
- SKU
- ISO/IEC 29341-6-14:2008
Похожие стандарты
Стандарты, упомянутые в описании
ISO/IEC 29341-11-1:2008
ДействующийInformation technology — UPnP Device Architecture — Part 11-1: Quality of Service Device Control Protocol - L…
Overview ISO/IEC 29341-11-1:2008 - "Information technology - UPnP Device Architecture - Part 11-1: Quality of Service Device Control Protocol - Level 2 - Quality of Service Architecture" specifies th…
ISO/IEC 29341-6-11:2008
ДействующийInformation technology — UPnP Device Architecture — Part 6-11: Heating, Ventilation, and Air Conditioning Dev…
Overview ISO/IEC 29341-6-11:2008 - "Information technology - UPnP Device Architecture - Part 6-11: Heating, Ventilation and Air Conditioning Device Control Protocol - Fan Operating Mode Service" defi…
ISO/IEC 29341-6-2:2008
ДействующийInformation technology - UPnP Device Architecture - Part 6-2: Heating, Ventilation, and Air Conditioning Devi…
ISO/IEC 29341-6-10:2008
ДействующийInformation technology - UPnP Device Architecture - Part 6-10: Heating, Ventilation, and Air Conditioning Dev…
Overview ISO/IEC 29341-6-10:2008, titled Information technology - UPnP Device Architecture - Part 6-10: Heating, Ventilation, and Air Conditioning Device Control Protocol - Control Valve Service, is…
ISO/IEC 29341-6-1:2008
ДействующийInformation technology - UPnP Device Architecture - Part 6-1: Heating, Ventilation, and Air Conditioning Devi…
ISO/IEC 29341-6-13:2008
ДействующийInformation technology - UPnP Device Architecture - Part 6-13: Heating, Ventilation, and Air Conditioning Dev…
Overview ISO/IEC 29341-6-13:2008 - Information technology - UPnP Device Architecture - Part 6-13: Heating, Ventilation, and Air Conditioning Device Control Protocol - House Status Service - defines a…
ISO/IEC 29341-6-15:2008
ДействующийInformation technology — UPnP Device Architecture — Part 6-15: Heating, Ventilation, and Air Conditioning Dev…
Overview ISO/IEC 29341-6-15:2008 - "Information technology - UPnP Device Architecture - Part 6-15: Heating, Ventilation and Air Conditioning Device Control Protocol - Temperature Sensor Service" defi…