SIST EN ISO 14146:2024
Radiological protection - Criteria and performance limits for the periodic evaluation of dosimetry services for external radiation (ISO 14146:2024)
Radiological protection - Criteria and performance limits for the periodic evaluation of dosimetry services for external radiation (ISO 14146:2024)
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 26
- Дата публикации:
- 16 августа 2024 г.
- Издание:
- ISO 14146:2024
- ICS:
- 13.280
This document specifies the dosimetric and organizational criteria and the test procedures to be used for the periodic verification of the performance of dosimetry services supplying personal and/or area, i.e. workplace and/or environmental, dosemeters used for individual (personal) and/or area, i.e. workplace and/or environmental monitoring. NOTE The quality of a supplier of a dosimetry service depends on both the characteristics of the approved (type‑tested) dosimetry system and the training and experience of the staff, together with the calibration procedures and quality assurance programmes. The performance evaluation according to this document can be carried out by a dosimetry service to demonstrate the fulfilment of specified performance requirements. The irradiation qualities used in this document are representative for exposure situations that are expected or mimic workplace fields from the radiological activities being monitored using the dosemeters from the services. This document applies to personal and area dosemeters for the assessment of external photon radiation with a fluence-weighted mean energy between 8 keV and 10 MeV, beta radiation with a fluence-weighted mean energy between 60 keV and 1,2 MeV, and neutron radiation with a fluence-weighted mean energy between 25,3 meV, i.e. thermal neutrons with a Maxwellian energy distribution with kT = 25,3 meV, and 200 MeV. It covers all types of personal and area dosemeters needing laboratory processing (e.g. thermoluminescent, optically stimulated luminescence, radiophotoluminescent, track detectors or photographic-film dosemeters) and involving continuous measurements or measurements repeated regularly at fixed time intervals (e.g. several weeks, one month). Active direct reading as well as semi-passive or hybrid dosemeters, such as direct ion storage (DIS) or silicon photomultiplier (SiPM) dosemeters, for dose measurement, can also be treated according to this document. Then, they are treated as if they were passive, i.e. the dosimetry service reads their indicated values and reports them to the evaluation organization. In this document, the corrected indicated (corrected indication) value is the one given by the dosimetry systems as the final result of the evaluation algorithm (for example display of the software, printout) in units of dose equivalent (Sv). Environmental dosemeters usually indicate the quantity H*(10) but they can, in addition or alternatively, indicate the quantity H'(3), H'(0,07), air kerma, Ka, or absorbed dose, D. All these dosemeters can also be treated according to this document. If Ka or D is indicated (in Gy) the dose values in this document stated in Sv shall then be interpreted as equivalent values in Gy.
Abstract
Overview
EN ISO 14146:2024 - Radiological protection - Criteria and performance limits for the periodic evaluation of dosimetry services for external radiation - specifies dosimetric and organizational criteria, test procedures and performance limits for the periodic verification of dosimetry services. Applicable to both personal dosemeters and area (workplace or environmental) dosemeters, the standard supports quality assurance of services that supply and process dosemeters for external photon, beta and neutron radiation.
Key topics and requirements
- Scope of applicability: External photon radiation (fluence-weighted mean energy 8 keV to 10 MeV), beta radiation (60 keV to 1.2 MeV) and neutrons (thermal 25.3 meV up to 200 MeV).
- Dosemeters covered: Laboratory‑processed passive types (thermoluminescent (TLD), optically stimulated luminescence (OSL), radiophotoluminescent (RPL), track, photographic film) and active or hybrid systems (DIS, SiPM) when evaluated as passive systems.
- Performance evaluation: Defines test conditions, irradiation qualities representative of workplace fields, dose ranges, and performance limits and approval criteria for corrected indicated values (final reported dose equivalent in sieverts).
- Organizational criteria: Addresses the role of staff training, calibration procedures and quality assurance programmes in the overall quality of a dosimetry service.
- Quantities: Treats dose equivalent (Sv) and environmental quantities such as H*(10), H'(3), H'(0.07), air kerma (Ka) and absorbed dose (D). If Ka or D are reported in gray (Gy) the standard interprets stated Sv values as equivalent Gy where applicable.
- Evaluation process: Specifies sample size, evaluation sequence, test reporting and frequency of periodic verification (examples in the standard include monitoring intervals such as several weeks to one month).
- Supporting material: Annex A (reference and standard test conditions) and Annex B (graphical illustrations of performance limits).
Applications and users
- Dosimetry service providers conducting internal or external periodic verification to demonstrate compliance with performance requirements.
- Calibration laboratories and accreditation bodies assessing conformance of dosimetry services.
- Radiation protection officers, employers and regulators who rely on validated personal and environmental monitoring results.
- Organizations implementing or harmonizing quality assurance for occupational and environmental radiation monitoring.
Related standards
- ISO 4037 series (X and gamma reference radiations)
- ISO 6980 series (reference beta radiation)
- ISO 8529 (neutron reference fields) These normative references provide the reference radiation fields and calibration methods used by EN ISO 14146:2024.
Keywords: EN ISO 14146:2024, dosimetry services, radiological protection, personal dosemeters, area dosemeters, performance evaluation, external radiation, H*(10), TLD, OSL, neutron dosimetry.
Технические детали
- Технический комитет
- I13 - Imaginarni 13
- SKU
- SIST EN ISO 14146:2024
Похожие стандарты
Стандарты, упомянутые в описании
ISO 14146:2024
ДействующийRadiological protection — Criteria and performance limits for the periodic evaluation of dosimetry services f…
Overview ISO 14146:2024 - Radiological protection - Criteria and performance limits for the periodic evaluation of dosimetry services for external radiation - defines the dosimetric and organizationa…
SIST EN ISO 4037-2:2021
ДействующийRadiological protection - X and gamma reference radiation for calibrating dosemeters and doserate meters and…
EN ISO 4037-2:2021 - Radiological protection: Dosimetry overview EN ISO 4037-2:2021 (ISO 4037-2:2019) specifies dosimetry procedures for X‑ and gamma‑ray reference radiation used to calibrate dosemet…
SIST EN ISO 6980-2:2025
ДействующийNuclear energy - Reference beta-particle radiation - Part 2: Calibration fundamentals related to basic quanti…
Overview EN ISO 6980-2:2025 - adopted by CEN from ISO 6980-2:2023 (corrected version 2024-03) - defines calibration fundamentals for reference beta-particle radiation fields used in nuclear energy an…
SIST EN ISO 8529-3:2024
ДействующийNeutron reference radiation fields - Part 3: Calibration of area and personal dosemeters and determination of…
Overview - EN ISO 8529-3:2024 (ISO 8529-3:2023, corr. 2023-09) EN ISO 8529-3:2024 is the CEN-adopted version of ISO 8529-3 and provides guidance for the calibration of area and personal neutron dosem…