SIST EN ISO 4037-4:2021
Radiological protection - X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy - Part 4: Calibration of area and personal dosemeters in low energy X reference radiation fields (ISO 4037-4:2019)
Radiological protection - X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy - Part 4: Calibration of area and personal dosemeters in low energy X reference radiation fields (ISO 4037-4:2019)
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 26
- Дата публикации:
- 22 февраля 2021 г.
- Издание:
- ISO 4037-4:2019
- ICS:
- 13.280
This document gives guidelines on additional aspects of the characterization of low energy photon radiations and on the procedures for calibration and determination of the response of area and personal dose(rate)meters as a function of photon energy and angle of incidence. This document concentrates on the accurate determination of conversion coefficients from air kerma to Hp(10), H*(10), Hp(3) and H'(3) and for the spectra of low energy photon radiations. As an alternative to the use of conversion coefficients the direct calibration in terms of these quantities by means of appropriate reference instruments is described.
Abstract
Overview
EN ISO 4037-4:2021 (ISO 4037-4:2019) specifies guidelines for the calibration of area and personal dosemeters in low energy X‑ray reference radiation fields (generating potential ≤ 30 kV). It focuses on characterization of low‑energy photon radiations and on procedures to determine dosemeter and dose‑rate meter response as a function of photon energy and angle of incidence. The standard emphasises accurate determination of conversion from air kerma to operational quantities such as Hp(10), *H(10)**, Hp(3) and H'(3) and describes an alternative - direct calibration using appropriate reference instruments.
Key Topics and Requirements
- Field characterization: Guidance on producing and characterising low energy X‑ray reference radiations (spectral fluence, tube potential and spectra).
- Dosimetry: Procedures for dosimetry in low energy reference fields, including stability checks and measurement traceability.
- Calibration methods: Two primary approaches:
- Using conversion coefficients from air kerma to operational quantities.
- Direct calibration in terms of operational quantities with reference instruments that measure ICRU dose equivalent quantities.
- Response determination: Measurement of dosemeter response versus photon energy and angle of incidence; requirements for test geometry and phantom use where applicable.
- Uncertainty and corrections: Requirements for statement of uncertainty (target overall uncertainty ~6–10% for phantom‑related operational quantities) and normative guidance such as air density correction (Annex A).
- Documentation: Procedures for reporting conventional quantity values, calibration results and associated uncertainties.
Applications
EN ISO 4037-4 is used to ensure reliable, traceable calibration for:
- Occupational radiation monitoring (personal and area monitoring).
- Calibration laboratories and national metrology institutes that provide accredited calibration services for low energy X fields.
- Quality assurance in fields dominated by low‑energy photons, e.g., diagnostic radiology, dental radiography, some industrial X‑ray inspections and workplace radiation protection.
- Manufacturers of dosemeters and dose‑rate meters to validate device performance across low photon energies and incident angles.
Who Uses This Standard
- Calibration laboratories and accreditation bodies
- National metrology institutes
- Health physics and radiation protection professionals
- Dosemeter and instrument manufacturers
- Regulatory agencies and hospital physicists
Related Standards
EN ISO 4037-4 is part of the ISO 4037 series on photon reference radiation fields and aligns with other parts that cover field production, dosimetry and calibration methods (see ISO 4037‑1, ISO 4037‑2, ISO 4037‑3). It also references ICRU operational quantity definitions and general calibration practice standards.
Keywords: EN ISO 4037-4:2021, ISO 4037-4, radiological protection, low energy X reference radiation, calibration, dosemeters, air kerma, Hp(10), H*(10), Hp(3), H'(3), dosimetry, conversion coefficients.
Технические детали
- Технический комитет
- I13 - Imaginarni 13
- SKU
- SIST EN ISO 4037-4:2021
Похожие стандарты
Стандарты, упомянутые в описании
ISO 4037-4:2019
ДействующийRadiological protection — X and gamma reference radiation for calibrating dosemeters and doserate meters and…
Overview ISO 4037-4:2019 is part of the ISO 4037 series on reference photon radiation fields and provides guidance for calibrating area and personal dosemeters in low energy X‑ray reference radiation…
SIST EN ISO 4037-2:2021
ДействующийRadiological protection - X and gamma reference radiation for calibrating dosemeters and doserate meters and…
EN ISO 4037-2:2021 - Radiological protection: Dosimetry overview EN ISO 4037-2:2021 (ISO 4037-2:2019) specifies dosimetry procedures for X‑ and gamma‑ray reference radiation used to calibrate dosemet…
SIST EN ISO 4037-1:2021
ДействующийRadiological protection - X and gamma reference radiation for calibrating dosemeters and doserate meters and…
Overview EN ISO 4037-1:2021 (ISO 4037-1:2019) defines the radiation characteristics and production methods for X‑ and gamma‑reference radiation used to calibrate protection-level dosemeters and dose‑…
SIST EN ISO 4037-3:2021
ДействующийRadiological protection - X and gamma reference radiation for calibrating dosemeters and doserate meters and…
Overview SIST EN ISO 4037-3:2021 (ISO 4037-3:2019) specifies procedures and data for the calibration of area and personal dosemeters and doserate meters used in radiological protection. It uses the X…