SIST ISO 11222:2004
Air quality -- Determination of the uncertainty of the time average of air quality measurements
Air quality -- Determination of the uncertainty of the time average of air quality measurements
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 20
- Дата публикации:
- 1 июня 2004 г.
- ICS:
- 13.040.01
- Технический комитет:
- KAZ - Air quality
ISO 11222:2002 provides a method for the quantification of the uncertainty of a time average of a set of air quality data obtained at a specified location over a defined averaging time period. The method is applicable to air quality data obtained by continuous or intermittent monitoring by means of a specified measuring system. The uncertainty of the time average depends on both the uncertainty of the measurement results and the uncertainty due to incomplete time coverage of the data set. ISO 11222:2002 is only applicable if the set of air quality data used to calculate the time average is representative of the temporal structure of the measurand over the defined time period, appropriate information on the uncertainty of the measurement results is available, and the measurement results have all been obtained at the same location. ISO 11222:2002 implements recommendations of the Guide to the Expression of Uncertainty in Measurement (GUM).
Abstract
Overview
ISO 11222:2002 - Air quality: Determination of the uncertainty of the time average of air quality measurements specifies a method to quantify the uncertainty of a time average computed from air quality data collected at a single location over a defined averaging period. The method applies to continuous or intermittent monitoring and follows the recommendations of the Guide to the Expression of Uncertainty in Measurement (GUM). It separates uncertainty contributions from the measuring system and from incomplete time coverage of the data set, and guides calculation of combined and expanded uncertainty for reporting.
Key topics and requirements
- Scope and applicability
- Applies when the data set is representative of the temporal structure of the measurand, measurement-uncertainty information is available, and all results come from the same location.
- Covers time averages of scalar measurement results (e.g., hourly, daily, monthly means).
- Main uncertainty contributions
- Measuring-system-induced uncertainty (instrument bias, calibration, procedural factors).
- Uncertainty due to incomplete time coverage (gaps or intermittent sampling that do not fully capture temporal variability).
- Methodology
- Implements GUM principles: estimate standard uncertainties, combine them (combined standard uncertainty), apply a coverage factor to obtain expanded uncertainty at a stated confidence level.
- Addresses degrees of freedom and how they affect the coverage factor for expanded uncertainty.
- Data and reporting requirements
- Requirements on input data (representativeness, number and timing of measurements).
- Reporting guidance for the time average and its uncertainty so results are reproducible and comparable.
- Support material
- Informative Annex A provides an example application (monthly average of nitrogen dioxide).
Applications and users
ISO 11222 is practical for organizations that produce, evaluate or use time-averaged air quality data:
- Environmental monitoring agencies and regulatory bodies assessing compliance with air-quality standards.
- Laboratory and field measurement teams designing monitoring campaigns (continuous or intermittent).
- Air quality modelers and data analysts who require quantified uncertainty on time-averaged inputs or validation data.
- Quality assurance / quality control (QA/QC) specialists setting data-quality objectives and performance criteria.
Benefits include more transparent compliance decisions, defensible reporting of averages (hourly, daily, monthly), and consistent handling of gaps and instrument-related uncertainty.
Related standards
- GUM:1995 - Guide to the expression of uncertainty in measurement (normative reference used by ISO 11222).
- References in ISO 11222 also include statistical and metrology documents (e.g., VIM, ISO 3534-1) used for definitions and terms.
Keywords: ISO 11222:2002, air quality, uncertainty of time average, measurement uncertainty, GUM, continuous monitoring, intermittent monitoring, incomplete time coverage.
Технические детали
- SKU
- SIST ISO 11222:2004
Похожие стандарты
Упомянутые в описании и другие стандарты SIST
ISO 11222:2002
ДействующийAir quality — Determination of the uncertainty of the time average of air quality measurements
Overview ISO 11222:2002 - Air quality: Determination of the uncertainty of the time average of air quality measurements specifies a method to quantify the uncertainty of a time average computed from…
SIST ISO 3534-1:2008
ДействующийStatistics - Vocabulary and symbols - Part 1: General statistical terms and terms used in probability
Overview ISO 3534-1:2006 - "Statistics - Vocabulary and symbols - Part 1: General statistical terms and terms used in probability" defines standardized terminology and a limited set of symbols for co…
SIST EN ISO 6338:2026
ДействующийMethod to calculate GHG emissions at LNG plant (ISO 6338:2023)
Overview SIST EN ISO 6338:2026 / ISO 6338:2023 establishes a standardized method for calculating greenhouse gas (GHG) emissions at liquefied natural gas (LNG) plants, both onshore and offshore. Devel…
SIST-TP CEN ISO/ASTM TR 52958:2026
Additive manufacturing of metals - Powder bed fusion (PBF) - In-situ coaxial photodiode monitoring for lack o…
Overview SIST-TP CEN ISO/ASTM TR 52958:2026 specifies a workflow for the detection of lack of fusion flaws during the additive manufacturing of metals using powder bed fusion-laser based (PBF-LB) pro…
SIST EN ISO 41002:2026
ДействующийFacility management - Development of the facility management organization (ISO 41002:2026)
Overview SIST EN ISO 41002:2026 - Facility management - Development of the facility management organization offers strategic guidance for building and developing robust facility management (FM) organ…
SIST EN ISO 844:2026
ДействующийRigid cellular plastics - Determination of compressive properties (ISO 844:2026)
Overview SIST EN ISO 844:2026 - Rigid Cellular Plastics: Determination of Compressive Properties (ISO 844:2026) provides standardized methods for measuring the compressive properties of rigid cellula…
SIST-TS CEN ISO/TS 17664-3:2026
ДействующийProcessing of health care products - Information to be provided by the medical device manufacturer for the pr…
Overview SIST-TS CEN ISO/TS 17664-3:2026 sets out comprehensive guidance for grouping reusable medical devices based on their cleaning requirements. This technical specification, prepared collaborati…
SIST EN ISO 8980-4:2026
ДействующийOphthalmic optics - Uncut finished spectacle lenses - Part 4: Specifications and test methods for the propert…
Overview SIST EN ISO 8980-4:2026 specifies requirements and test methods for the properties of anti-reflective coatings and hydrophobic coatings applied to uncut finished spectacle lenses. Developed…