EN ISO 11608-2:2022 PDF
Needle-based injection systems for medical use - Requirements and test methods - Part 2: Double-ended pen needles (ISO 11608-2:2022)
Needle-based injection systems for medical use - Requirements and test methods - Part 2: Double-ended pen needles (ISO 11608-2:2022)
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 40
- Дата публикации:
- 4 мая 2022 г.
- Издание:
- CEN EN 11608 edition 2 version 1
- ICS:
- 11.040.25
This document specifies requirements and test methods for single-use, double-ended, sterile needles intended to be used with some needle-based injection systems (NISs) that use a non-integrated double-ended needle according to ISO 11608-1. This document is not applicable to the following: — needles for dental use; — pre-attached syringe needles; — hypodermic needles; — needles intended for different routes of administration (e.g. intravenous, intrathecal, intraocular); — materials that form the medicinal product contact surfaces of the primary container closure. However, while this document is not intended to directly apply to these needle products, it does contain requirements and tests methods that can be used to help design and evaluate them. NOTE Needles provided by the manufacturer integrated into the fluid path or container are covered in ISO 11608‑3, and hypodermic needles provided separately are covered in ISO 7864.
Abstract
Overview
EN ISO 11608-2:2022 - "Needle-based injection systems for medical use - Requirements and test methods - Part 2: Double-ended pen needles" is the CEN-adopted European version of ISO 11608-2:2022. It specifies requirements and test methods for single-use, sterile double-ended pen needles intended for use with certain needle-based injection systems (NISs) that use a non-integrated double-ended needle. The standard excludes dental needles, pre-attached syringe needles, hypodermic needles for other routes (e.g., intravenous, intrathecal, intraocular), and primary container contact materials - though many of its tests and design criteria can inform those products.
Key topics and technical requirements
This document defines technical requirements and standardized test methods for double-ended pen needles, covering:
- Needle tube materials and tubing characteristics - material selection and dimensional expectations for needle tubes.
- Double-ended pen needle assembly requirements - hub geometry, dimensions, and freedom from defects.
- Needle points and flow rate - needle tip characteristics and methods to determine fluid flow rate through the needle (see Annex A).
- Bonding strength and hub integrity - tests for the bond between hub and needle tube (normative and informative test methods).
- Functional compatibility with NISs - dose delivery accuracy, needle removal torque, and compatibility test procedures with pen injectors.
- Biocompatibility, sterility and pyrogenicity - requirements to ensure safety of single-use, sterile needles.
- Preconditioning, sampling and standard test atmosphere - conditions for preconditioning samples (dry heat, cold, damp heat, cyclic atmospheres) and standard laboratory atmosphere for testing.
- Packaging, labeling and instructions for use - marking requirements and user information to support safe use.
- Test apparatus and methods - standardized gauges and apparatus descriptions, plus sampling plans.
Practical applications and users
EN ISO 11608-2:2022 is essential for:
- Manufacturers of double-ended pen needles and pen injectors - for product design, verification and conformity.
- Medical device test laboratories - for performing required bond, flow, dose delivery and compatibility tests.
- Regulatory and quality assurance teams - to demonstrate compliance with recognized test methods and requirements.
- Procurement and clinical engineers - to specify devices that meet standardized performance and safety criteria.
Using this standard helps ensure consistent product safety, performance, sterility and user information for needle-based injection systems.
Related standards
- ISO 11608-1 - general requirements and test methods for needle-based injection systems (referenced for alignment of sample sizes and test frameworks).
- ISO 11608-3 - needles integrated into the fluid path or container.
- ISO 7864 - separately supplied hypodermic needles.
Keywords: EN ISO 11608-2:2022, double-ended pen needles, needle-based injection systems, NIS, pen needle testing, sterile needles, flow rate, biocompatibility, medical device standards.
Технические детали
- Технический комитет
- CEN/TC 205 - Non-active medical devices
- SKU
- EN ISO 11608-2:2022
Похожие стандарты
Стандарты, упомянутые в описании
ISO 11608-2:2022
ДействующийNeedle-based injection systems for medical use — Requirements and test methods — Part 2: Double-ended pen nee…
Overview ISO 11608-2:2022 specifies requirements and test methods for single-use, sterile double-ended pen needles used with needle-based injection systems (NISs), such as pen injectors. Part 2 of th…
SIST EN ISO 11608-1:2022
ДействующийNeedle-based injection systems for medical use - Requirements and test methods - Part 1: Needle-based injecti…
Overview EN ISO 11608-1:2022 - Needle-based injection systems for medical use - Part 1: Needle-based injection systems (ISO 11608-1:2022) specifies requirements and test methods for needle-based inje…
EN ISO 11608-3:2022/A1:2026
ДействующийNeedle-based injection systems for medical use - Requirements and test methods - Part 3: Containers and integ…
Overview EN ISO 11608-3:2022/A1:2026 specifies updated requirements and test methods for containers and integrated fluid paths in needle-based injection systems (NIS) for medical use. Issued by CEN a…
SIST EN ISO 7864:2016
ДействующийSterile hypodermic needles for single use - Requirements and test methods (ISO 7864:2016)
Overview SIST EN ISO 7864:2016 specifies international requirements and test methods for sterile hypodermic needles intended for single use, covering metric sizes from 0.18 mm to 1.2 mm. This standar…