EN ISO 12020:2000 PDF
Water quality - Determination of aluminium - Atomic absorption spectrometric methods (ISO 12020:1997)
Water quality - Determination of aluminium - Atomic absorption spectrometric methods (ISO 12020:1997)
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 12
- Дата публикации:
- 27 января 2000 г.
- Издание:
- CEN EN 12020 edition 1 version 1
- ICS:
- 13.060.01
Describes a flame atomic absorption spectrometric method and a graphite furnace atomic absorption spectrometric method for the determination of aluminium in water. The flame AAS method is applicable to mass concentrations from 5 mg/l to 100 mg/l and the graphite furnace AAS method is applicable to mass concentrations from 10 g/l to 100 g/l in water and waste water.
Abstract
Overview
EN ISO 12020:2000 defines standardized methods for determining aluminium concentrations in water using atomic absorption spectrometry (AAS). Developed by CEN in alignment with ISO 12020:1997, this standard covers both flame AAS and graphite furnace AAS techniques. The methods are applicable for the analysis of aluminium in various types of water, including drinking water and waste water, essential for ensuring water quality in environmental monitoring and compliance.
Key Topics
-
Flame Atomic Absorption Spectrometric Method
- Applicable for measuring aluminium concentrations from 5 mg/l to 100 mg/l in water samples.
- Suitable for higher concentrations if samples are diluted appropriately.
- Includes sample digestion procedures for determining total aluminium content, though some complex forms (e.g., silicates, aluminium oxides) may not be fully detected.
-
Graphite Furnace Atomic Absorption Spectrometric Method
- Enables detection of aluminium at concentrations as low as 10 μg/l up to 100 μg/l, making it ideal for low-level analyses.
- Method flexibility to accommodate a broader range via dilution or smaller sample volume.
- Employs specialized techniques to minimize matrix interferences and improve accuracy.
-
Sample Preparation and Interferences
- Detailed procedures for sample collection, filtration, and acidification to stabilize samples.
- Guidance on handling potential interferences from other ions commonly present in water.
- Emphasis on avoiding contamination, especially at low detection limits.
-
Calibration and Quality Assurance
- Step-by-step instructions for preparing calibration standards and blank solutions.
- Recommendations for routine instrument zeroing and performance verification.
- Directions for data calculation and expression of results, including reporting to significant figures.
Applications
The standardized methods described in EN ISO 12020:2000 are critical in several practical contexts:
- Drinking Water Analysis: Ensures aluminium levels comply with regulatory guidelines to protect public health.
- Environmental Monitoring: Supports routine surveillance of rivers, lakes, and groundwaters for trace aluminium.
- Waste Water Compliance: Crucial for industrial and municipal effluent management, helping facilities meet environmental discharge permits.
- Research and Laboratory Studies: Provides a reliable foundation for scientific studies involving aluminium in aquatic environments.
- Accredited Laboratory Testing: Assures clients and regulators of method consistency, quality control, and internationally recognized procedures.
Adhering to this standard fosters reliable water quality assessment and supports environmental and public health objectives.
Related Standards
Several international and European standards complement EN ISO 12020:2000 in the field of water quality analysis:
-
ISO 5667 Series:
- ISO 5667-1: Water quality - Sampling - Part 1: Guidance on the design of sampling programmes
- ISO 5667-2: Water quality - Sampling - Part 2: Guidance on sampling techniques
- ISO 5667-3: Water quality - Sampling - Part 3: Guidance on the preservation and handling of samples
-
ISO 10523: Water quality - Determination of pH
-
ISO 11885: Water quality - Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES)
Using EN ISO 12020:2000 alongside these related standards enables comprehensive, accurate, and standardized water quality testing and reporting, ensuring results are comparable across laboratories and regions.
Keywords: aluminium determination, water quality, atomic absorption spectrometry, EN ISO 12020:2000, flame AAS, graphite furnace AAS, water analysis, CEN standards, water testing, laboratory methods, environmental compliance.
Технические детали
- Технический комитет
- CEN/TC 230 - Water analysis
- SKU
- EN ISO 12020:2000
Похожие стандарты
Стандарты, упомянутые в описании
ISO 12020:1997
ДействующийWater quality — Determination of aluminium — Atomic absorption spectrometric methods
Overview ISO 12020:1997 specifies two atomic absorption spectrometric (AAS) methods for the determination of aluminium (Al) in water and wastewater. It covers a flame AAS procedure (nitrous oxide/ace…
BS ISO 5667-21:2010
ДействующийWater quality. Sampling - Guidance on sampling of drinking water distributed by tankers or means other than d…
BS ISO 5667-21:2010 Water quality. Sampling. Guidance on sampling of drinking water distributed by tankers or means other than distribution pipes This part of BS ISO 5667 establishes principles to be…
SIST EN ISO 5667-1:2023
ДействующийWater quality - Sampling - Part 1: Guidance on the design of sampling programmes and sampling techniques (ISO…
Overview EN ISO 5667-1:2023 - "Water quality - Sampling - Part 1" (CEN adoption of ISO 5667-1:2023) provides general principles and guidance for the design of sampling programmes and sampling techniq…
ISO 5667-3:2024
ДействующийWater quality — Sampling — Part 3: Preservation and handling of water samples
Overview ISO 5667-3:2024 - Water quality - Sampling - Part 3: Preservation and handling of water samples is the sixth edition of the ISO guidance on how to preserve, handle, transport and store water…
SIST EN ISO 10523:2012
ДействующийWater quality - Determination of pH (ISO 10523:2008)
Overview EN ISO 10523:2012 (identical to ISO 10523:2008) specifies a standardized electrometric method for determination of pH in water. It covers rain, drinking and mineral waters, bathing, surface…
SIST EN ISO 11885:2009
ДействующийWater quality - Determination of selected elements by inductively coupled plasma optical emission spectrometr…
Overview EN ISO 11885:2009 - adopted from ISO 11885:2007 - defines a standardized laboratory method for the determination of selected elements in water using inductively coupled plasma optical emissi…