ISO 15118-5:2018 specifies conformance tests in the form of an Abstract Test Suite (ATS) for a System Under Test (SUT) implementing an Electric Vehicle or Supply Equipment Communication Controller (EVCC or SECC) with support for PLC-based High Level Communication (HLC) and Basic Signaling according to ISO 15118‑3. These conformance tests specify the testing of capabilities and behaviors of an SUT, as well as checking what is observed against the conformance requirements specified in ISO 15118‑3 and against what the implementer states the SUT implementation's capabilities are. The capability tests within the ATS check that the observable capabilities of the SUT are in accordance with the static conformance requirements defined in ISO 15118‑3. The behavior tests of the ATS examine an implementation as thoroughly as is practical over the full range of dynamic conformance requirements defined in ISO 15118‑3 and within the capabilities of the SUT (see NOTE 1). A test architecture is described in correspondence to the ATS. The conformance test cases in this part of the standard are described leveraging this test architecture and are specified in TTCN-3 Core Language for the ISO/OSI Physical and Data Link Layers (Layers 1 and 2). The conformance test cases for the ISO/OSI Network Layer (Layer 3) and above are described in ISO 15118‑4. In terms of coverage, this document only covers normative sections and requirements in ISO 15118‑3. This document can additionally include specific tests for requirements of referenced standards (e.g. IEEE, or industry consortia standards) as long as they are relevant in terms of conformance for implementations according to ISO 15118‑3. However, it is explicitly not intended to widen the scope of this conformance specification to such external standards, if it is not technically necessary for the purpose of conformance testing for ISO 15118‑3. Furthermore, the conformance tests specified in this document do not include the assessment of performance nor robustness or reliability of an implementation. They cannot provide judgments on the physical realization of abstract service primitives, how a system is implemented, how it provides any requested service, nor the environment of the protocol implementation. Furthermore, the test cases defined in this document only consider the communication protocol and the system's behavior defined ISO 15118‑3. Power flow between the EVSE and the EV is not considered. NOTE 1 Practical limitations make it impossible to define an exhaustive test suite, and economic considerations can restrict testing even further. Hence, the purpose of this document is to increase the probability that different implementations are able to interwork. This is achieved by verifying them by means of a protocol test suite, thereby increasing the confidence that each implementation conforms to the protocol specification. However, the specified protocol test suite cannot guarantee conformance to the specification since it detects errors rather than their absence. Thus conformance to a test suite alone cannot guarantee interworking. What it does do is give confidence that an implementation has the required capabilities and that its behavior conforms consistently in representative instances of communication. NOTE 2 This document has some interdependencies to the conformance tests defined in ISO 15118‑4 which result from ISO/OSI cross layer dependencies in the underlying protocol specification (e.g. for sleep mode)
Abstract
Overview
EN ISO 15118-5:2019 (ISO 15118-5:2018) defines conformance testing for the physical layer and data link layer of the Vehicle-to-Grid (V2G) communication stack. It provides an Abstract Test Suite (ATS) to verify implementations of an Electric Vehicle Communication Controller (EVCC) or Supply Equipment Communication Controller (SECC) that use PLC-based High Level Communication (HLC) and Basic Signaling per ISO 15118‑3. The document describes a test architecture and expresses test cases in TTCN‑3 for ISO/OSI Layers 1 and 2.
Key technical topics and requirements
- Scope of conformance: Tests cover normative requirements in ISO 15118‑3 related to the physical and data link layers; Layer 3+ tests are in ISO 15118‑4.
- Abstract Test Suite (ATS): Defines capability tests (static conformance) and behavior tests (dynamic conformance) that check observable SUT capabilities against ISO 15118‑3 and the implementer’s declared capabilities.
- Test architecture: Reference model including platform adapters, SUT adapters, codecs and interfaces for controlled conformance testing.
- TTCN‑3 test specifications: Test cases and modules are specified in TTCN‑3 Core Language for repeatable automated testing of PLC HLC and SLAC/HPGP PLC signal interactions.
- PICS / PIXIT: Protocol Implementation Conformance Statement (PICS) and Protocol Implementation Extra Information for Testing (PIXIT) definitions and configurations for EVCC/SECC test profiles.
- Test coverage and conventions: Test suite structure, identifiers, timers, verdicts, and mapping of ATS coverage to ISO 15118‑3 requirements.
- Examples and PLC specifics: Includes PLC signal measurement and SLAC-related test cases (e.g., CmSlacParm, AttenuationCharacterization, CmValidate, CmSlacMatch, PLCLinkStatus, CmAmpMap) as part of the ATS.
- Limitations: Conformance tests do not assess performance, robustness, reliability, power flow, or physical implementation details. The test suite increases confidence in conformance but cannot guarantee interworking.
Practical applications and who uses this standard
- EV and EVSE (charging station) manufacturers - to validate V2G PLC implementations (EVCC/SECC) against ISO 15118‑3.
- Conformance and certification laboratories - to run standardized TTCN‑3 test cases for physical and data link layer accreditation.
- Systems integrators and test engineers - for automated test design, PICS/PIXIT configuration and interoperability verification.
- Standards and compliance teams - to document test coverage, produce conformance reports, and support certification processes.
- Developers working on SLAC/HPGP PLC stacks - to ensure correct signaling, attenuation characterization and link status behaviors.
Related standards (for context)
- ISO 15118‑3 - protocol specification for the physical and data link layers (normative reference for tests)
- ISO 15118‑4 - conformance testing for network and higher layers
- Relevant PLC and industry specifications (e.g., IEEE or consortia standards) may be referenced where required by ISO 15118‑3, but ISO 15118‑5 does not extend conformance scope to unrelated external standards.
Keywords: ISO 15118-5:2019, V2G, vehicle-to-grid communication, EVCC, SECC, PLC HLC, physical layer conformance, data link layer conformance, TTCN-3, ISO 15118-3, conformance testing, PICS, PIXIT, SLAC, HPGP.
Технические детали
- Технический комитет
- CEN/TC 301 - Electrically propelled road vehicles
- SKU
- EN ISO 15118-5:2019
Похожие стандарты
Стандарты, упомянутые в описании
ISO 15118-5:2018
ДействующийRoad vehicles - Vehicles to grid communication interface - Part 5: Physical and data link layer conformance t…
Overview ISO 15118-5:2018 - Road vehicles - Vehicle to grid communication interface - Part 5: Physical and data link layer conformance tests - defines an Abstract Test Suite (ATS) for conformance tes…
SIST EN ISO 15118-3:2016
ДействующийRoad vehicles - Vehicle to grid Communication interface - Part 3: Physical and data link layer requirements (…
Overview - EN ISO 15118-3:2016 (ISO 15118-3:2015) EN ISO 15118-3 defines the physical layer and data link layer requirements for wired vehicle-to-grid (V2G) communication between electric vehicles (B…
SIST EN ISO 15118-4:2019
ДействующийRoad vehicles - Vehicle to grid communication interface - Part 4: Network and application protocol conformanc…
Overview EN ISO 15118-4:2019 (ISO 15118-4:2018) specifies a protocol conformance test framework for the vehicle-to-grid (V2G) communication interface. It defines an Abstract Test Suite (ATS) used to…
SIST EN ISO 15118-5:2019
ДействующийRoad vehicles - Vehicle to grid communication interface - Part 5: Physical layer and data link layer conforma…
Overview SIST EN ISO 15118-5:2019 (ISO 15118-5:2018) defines conformance testing for the physical layer and data link layer of the Vehicle-to-Grid (V2G) communication stack. It provides an Abstract T…