EN ISO 15493:2003/A1:2017 PDF
Plastics piping systems for industrial applications - Acrylonitrile-butadiene-styrene (ABS), unplasticized poly(vinyl chloride) (PVC-U) and chlorinated poly(vinyl chloride) (PVC-C) - Specifications for components and the system - Metric series - Amendment 1 (ISO 15493:2003/Amd 1:2016 + Cor 1:2004)
Plastics piping systems for industrial applications - Acrylonitrile-butadiene-styrene (ABS), unplasticized poly(vinyl chloride) (PVC-U) and chlorinated poly(vinyl chloride) (PVC-C) - Specifications for components and the system - Metric series - Amendment 1 (ISO 15493:2003/Amd 1:2016 + Cor 1:2004)
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 6
- Дата публикации:
- 25 января 2017 г.
- Издание:
- CEN EN 15493 edition 1 version 1
- ICS:
- 23.040.01
2016-09-01 - At publication, add text into European Foreword to include reference to ISO Corrigendum published in 2004 (see email on network).
Abstract
Overview
EN ISO 15493:2003/A1:2017 (CEN adoption of ISO 15493:2003 with Amendment 1) specifies requirements for plastics piping systems for industrial applications made from ABS, PVC‑U and PVC‑C. It is a metric‑series standard covering materials, component specifications, system performance and required tests. Amendment 1 updates material declarations, hydrostatic strength, adhesive requirements and several test‑related tables and annex clauses to reflect current industry practice and includes a European Foreword reference to an earlier ISO corrigendum.
Key topics and technical requirements
- Scope and materials
- Applies to piping components manufactured from ABS, unplasticized PVC (PVC‑U) and chlorinated PVC (PVC‑C), including permitted additives for manufacture.
- Material properties
- For PVC‑C the amendment specifies density 1 450–1 650 kg/m3 and chlorine ≥ 55% by mass (conformity declared by raw‑material producer).
- Thermal stability
- Thermal stability for pipes judged by internal‑pressure tests (e.g., 95 °C, ≥ 8 760 h, 3.6 MPa for pipes; fittings with corresponding conditions at 90 °C, ≥ 8 760 h, 3.1 MPa).
- Hydrostatic/internal‑pressure testing
- Adhesives and solvent cementing
- Adhesive(s) shall be as recommended by the component manufacturer and must not cause assemblies to fail the referenced annex tests. The amendment also removes certain detailed tapered socket dimensions for solvent cementing.
- Physical tests
- References to Vicat softening temperature testing with allowance for annealing samples per manufacturer recommendations.
- Referenced test standards
Applications and users
- Practical use: selection, design, manufacturing and quality control of industrial piping systems carrying water, chemicals and other fluids where ABS, PVC‑U or PVC‑C are appropriate.
- Typical users:
- Pipe, fitting and valve manufacturers
- Product designers and system specifiers in chemical and process industries
- Test laboratories and conformity assessment bodies
- Procurement teams and regulators creating technical specifications
Related standards
- ISO 15493:2003 (base standard)
- ISO 1167, ISO 12092 (internal pressure testing)
- ISO 3514, ISO 1158 (material property tests)
- National and CEN implementations (EN ISO 15493 series)
Keywords: EN ISO 15493:2003/A1:2017, plastics piping systems, ABS, PVC‑U, PVC‑C, industrial piping, internal‑pressure test, thermal stability, solvent cementing, Vicat softening temperature.
Технические детали
- Технический комитет
- CEN/TC 155 - Plastics piping systems and ducting systems
- SKU
- EN ISO 15493:2003/A1:2017
Похожие стандарты
Стандарты, упомянутые в описании
ISO 15493:2003
ДействующийPlastics piping systems for industrial applications — Acrylonitrile-butadiene-styrene (ABS), unplasticized po…
Overview ISO 15493:2003 - Plastics piping systems for industrial applications - specifies requirements for components and complete systems made from ABS, PVC‑U and PVC‑C (metric series). Published in…
SIST EN ISO 1167-4:2008
ДействующийThermoplastics pipes, fittings and assemblies for the conveyance of fluids - Determination of the resistance…
Overview EN ISO 1167-4:2007 - "Thermoplastics pipes, fittings and assemblies for the conveyance of fluids - Determination of the resistance to internal pressure - Part 4: Preparation of assemblies" s…
ISO 1209-2:2004
ОтменёнRigid cellular plastics — Determination of flexural properties — Part 2: Determination of flexural strength a…
ISO 3514:1976
ДействующийChlorinated polyvinyl chloride (CPVC) pipes and fittings — Specification and determination of density
Overview ISO 3514:1976 is an international standard established by the International Organization for Standardization (ISO) that specifies the measurement and acceptable density range for chlorinated…
BS EN ISO 1158:2026
ДействующийPlastics — Vinyl chloride homopolymers and copolymers — Determination of chlorine content.
ISO 15493:2003/Amd 1:2016
ДействующийPlastics piping systems for industrial applications — Acrylonitrile-butadiene-styrene (ABS), unplasticized po…
ISO 15493:2003/Amd 1:2016 Overview ISO 15493:2003/Amd 1:2016 is an essential international standard that specifies requirements for plastics piping systems used in industrial applications. This amend…